Primary Stability Assessment of Patient-Specific Transfemoral Osseointegrated Implants During Static Load-Bearing Exercise: A Comparative Analysis
Source abstract
Abstract
The long-term effectiveness of osseointegrated implants is heavily dependent on the short-term stability, primarily achieved immediately after surgery through a mechanical connection between the bone and the implant. The most common implant designs nowadays are straight and rely on screw or press-fit fixtures. Despite the promising results achieved by current transfemoral implants, the incidence of early failures and complications is still high. Starting from the hypothesis that a patient-specific approach could lead to better primary stability immediately post-surgery, this study aims to investigate the effect of implant design on primary stability. This was performed by analyzing two patient-specific implants, customized according to the medullary canal morphology, and a simple straight implant as the reference standard. To quantitatively assess the primary stability, a comparative computational analysis was conducted to examine the effective contact area, the relative micromotion, and the stress distribution at the interface between the bone and the implant stem during a static load-bearing exercise. The results showed that implants that follow the curvature of the residual femur provide lower micromotion values and a wider contact area, with a reduction of up to 30.4% and an increase of 10.8%, respectively, compared to the straight design, leading to a more homogeneous load distribution. Patient-specific prosthetic implants allow a more homogenous contact distribution that could lead to higher primary stability by reducing micromotion at the bone–implant interface concerning the straight profile, lowering the risk of loosening related to the short-term stability.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Engineering, University of Palermo, Viale delle Scienze Ed.8, 90128 Palermo, Italy
References (51)
Show source-provided references
1. Osseointegration in Skeletal Reconstruction and Rehabilitation: A Review
2. Osseointegration for Amputees: Current Implants, Techniques, and Future Directions10.2106/JBJS.RVW.19.00043 ↗
3. Safety of Osseointegrated Implants for Transfemoral Amputees: A Two-Center Prospective Cohort Study10.2106/JBJS.15.00808 ↗
4. Design Features of Implants for Direct Skeletal Attachment of Limb Prostheses10.1002/jbm.a.34606 ↗
5. Biomechanical Characterisation of Bone-Anchored Implant Systems for Amputation Limb Prostheses: A Systematic Review10.1007/s10439-017-1976-4 ↗
6. Prochor, P., and Sajewicz, E. (2019). The Influence of Geometry of Implants for Direct Skeletal Attachment of Limb Prosthesis on Rehabilitation Program and Stress-Shielding Intensity. Biomed. Res. Int., 2019.10.1155/2019/6067952 ↗
7. Influence of Trabecular Bone Quality and Implantation Direction on Press-Fit Mechanics10.1002/jor.23257 ↗
8. Lower Limb Prosthetic Interfaces: Clinical and Technological Advancement and Potential Future Direction10.1177/0309364620969226 ↗
9. Di Paolo, S., Barone, G., Alesi, D., Mirulla, A.I., Gruppioni, E., Zaffagnini, S., and Bragonzoni, L. (2023). Longitudinal Gait Analysis of a Transfemoral Amputee Patient: Single-Case Report from Socket-Type to Osseointegrated Prosthesis. Sensors, 23.10.3390/s23084037 ↗
10. A Nonlinear Homogenized Finite Element Analysis of the Primary Stability of the Bone–Implant Interface10.1007/s10237-018-1038-3 ↗
11. Osseointegration for Lower-Limb Amputation: A Systematic Review of Clinical Outcomes10.2106/JBJS.RVW.17.00037 ↗
12. Atallah, R., van de Meent, H., Verhamme, L., Frölke, J.P., and Leijendekkers, R.A. (2020). Safety, Prosthesis Wearing Time and Health-Related Quality of Life of Lower Extremity Bone-Anchored Prostheses Using a Press-Fit Titanium Osseointegration Implant: A Prospective One-Year Follow-up Cohort Study. PLoS ONE, 15.10.1371/journal.pone.0230027 ↗
13. Biomechanical Behaviour of Bone-Implant Interface: A Review Biomechanical Behaviours of the Bone-Implant Interface: A Review10.1098/rsif.2019.0259 ↗
14. Le Béguec, P., and Sieber, H.-P. (2007). The Concept of “Press-Fit”. Revision of Loose Femoral Prostheses: With a Stem System Based on the “Press-Fit” Principle: A Concept and a System of Implants: A Method and Its Results, Springer.
15. Large-Sliding Contact Elements Accurately Predict Levels of Bone-Implant Micromotion Relevant to Osseointegration10.1016/S0021-9290(00)00140-8 ↗
16. Effect of the Initial Implant Fitting on the Predicted Secondary Stability of a Cementless Stem10.1007/BF02344635 ↗
17. Predicting the Subject-Specific Primary Stability of Cementless Implants during Pre-Operative Planning: Preliminary Validation of Subject-Specific Finite-Element Models10.1016/j.jbiomech.2006.10.042 ↗
18. Numerical Analysis of an Osseointegrated Prosthesis Fixation with Reduced Bone Failure Risk and Periprosthetic Bone Loss10.1016/j.jbiomech.2012.05.032 ↗
19. FE Stress Analysis of the Interface between the Bone and an Osseointegrated Implant for Amputees—Implications to Refine the Rehabilitation Program10.1016/j.clinbiomech.2008.06.012 ↗
20. Factors Influencing Stability at the Interface between a Porous Surface and Cancellous Bone: A Finite Element Analysis of a Canine in Vivo Micromotion Experiment10.1002/(SICI)1097-4636(199708)36:2<274::AID-JBM17>3.0.CO;2-G ↗
21. Optimization of Custom Cementless Stem Using Finite Element Analysis and Elastic Modulus Distribution for Reducing Stress-Shielding Effect10.1177/0954411916686125 ↗
22. Subject Specific Finite Element Analysis of Implant Stability for a Cementless Femoral Stem10.1016/j.clinbiomech.2009.03.009 ↗
23. Mechanical Micromodeling of Stress-Shielding at the Bone-Implant Interphase under Shear Loading10.1007/s11517-022-02657-2 ↗
24. Quantification of Interfacial Motions Following Primary and Revision Total Knee Arthroplasty: A Verification Study versus Experimental Data10.1002/jor.23653 ↗
25. Measures of Micromotion in Cementless Femoral Stems-Review of Current Methodologies
26. A New Method to Evaluate the Influence of the Glenosphere Positioning on Stability and Range of Motion of a Reverse Shoulder Prosthesis10.1016/j.injury.2019.01.039 ↗
27. Ingrassia, T., Nigrelli, V., Pecorella, D., Bragonzoni, L., and Ricotta, V. (2020). Influence of the Screw Positioning on the Stability of Locking Plate for Proximal Tibial Fractures: A Numerical Approach. Appl. Sci., 10.10.3390/app10144941 ↗
28. Biomechanical Effects of Bone Quality and Design Features in Dental Implants in Long-Term Bone Stability
29. Simulated Bone Remodeling around Two Types of Osseointegrated Implants for Direct Fixation of Upper-Leg Prostheses10.1016/j.jmbbm.2012.06.015 ↗
30. Effect of Amputation Level on the Stress Transferred to the Femur by an Artificial Limb Directly Attached to the Bone10.1016/j.medengphy.2013.07.007 ↗
31. Risk of Failure during Gait for Direct Skeletal Attachment of a Femoral Prosthesis: A Finite Element Study10.1016/j.medengphy.2008.11.015 ↗
32. Ghaziani, A.O., Soheilifard, R., and Kowsar, S. (2021). The Effect of Functionally Graded Materials on Bone Remodeling around Osseointegrated Trans-Femoral Prostheses. J. Mech. Behav. Biomed. Mater., 118.10.1016/j.jmbbm.2021.104426 ↗
33. Taylor, C.E., Henninger, H.B., and Bachus, K.N. (2021). Finite Element Analysis of Transhumeral and Transtibial Percutaneous Osseointegrated Endoprosthesis Implantation. Front. Rehabil. Sci., 2.10.3389/fresc.2021.744674 ↗
34. Finite Element Analysis of Stresses Generated in Cortical Bone during Implantation of a Novel Limb Prosthesis Osseointegrated Fixation System10.1016/j.bbe.2016.12.001 ↗
35. A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations10.1007/s10439-010-9966-9 ↗
36. Lu, S., Vien, B.S., Russ, M., Fitzgerald, M., and Chiu, W.K. (2021, January 1–3). Novel Osseointegration Implant Optimization—Australasian Congress on Applied Mechanics. Proceedings of the ACAM10: 10th Australasian Congress on Applied Mechanics, Online.
37. Cirello, A., Ingrassia, T., Marannano, G., Mirulla, A.I., Nigrelli, V., Petrucci, G., and Ricotta, V. (2024). A New Automatic Process Based on Generative Design for CAD Modeling and Manufacturing of Customized Orthosis. Appl. Sci., 14.10.3390/app14146231 ↗
38. Li, Y., and Felländer-Tsai, L. (2021). The Bone Anchored Prostheses for Amputees—Historical Development, Current Status, and Future Aspects. Biomaterials, 273.10.1016/j.biomaterials.2021.120836 ↗
39. Direct Skeletal Attachment Prosthesis for the Amputee Athlete: The Unknown Potential10.1007/s12283-016-0196-8 ↗
40. Osseointegrierte Prothese Für Patienten Nach Amputation: Multidisziplinärer Behandlungsansatz in Den Niederlanden
41. The Role of Parameter Identification in Finite Element Contact Analyses with Reference to Orthopaedic Biomechanics Applications10.1016/S0021-9290(01)00163-4 ↗
42. Effect of Load on the Bone around Bone-Anchored Amputation Prostheses10.1002/jor.23352 ↗
43. Stem Geometry Changes Initial Femoral Fixation Stability of a Revised Press-Fit Hip Prosthesis: A Finite Element Study10.3233/THC-161235 ↗
44. A Continuous Wave Technique for the Measurement of the Elastic Properties of Cortical Bone10.1016/0021-9290(84)90029-0 ↗
45. Fretting Behavior of Cortical Bone against Titanium and Its Alloy10.1016/j.wear.2005.01.037 ↗
46. Static Load Bearing Exercises of Individuals with Transfemoral Amputation Fitted with an Osseointegrated Implant: Reliability of Kinetic Data10.1109/TNSRE.2014.2337956 ↗
47. Dassault Systèmes Simulia Corp (2021). ABAQUS/Standard User’s Manual, Version 2021, Simulia.
48. Mirulla, A.I., Pinelli, S., Zaffagnini, S., Nigrelli, V., Ingrassia, T., Di Paolo, S., and Bragonzoni, L. (2021). Numerical Simulations on Periprosthetic Bone Remodeling: A Systematic Review. Comput. Methods Programs Biomed., 204.10.1016/j.cmpb.2021.106072 ↗
49. Radiographic Evaluation of Bone Remodeling Around Osseointegration Implants among Transfemoral Amputees10.1097/BOT.0000000000001488 ↗
50. Benfratello, S., Cirello, A., Palizzolo, L., Sanfilippo, C., and Valenza, A. (2024). Experimental Analysis and Numerical Modelling of the Mechanical Behavior of a Sisal-Fiber-Reinforced Geopolymer. Appl. Sci., 14.10.3390/app14125216 ↗
51. Patient-Specific Design Process and Evaluation of a Hip Prosthesis Femoral Stem10.1177/0391398818815479 ↗