Comparative Analysis of Distribution Transformers with Varying Ratings and Insulation States via Frequency Domain Spectroscopy and Capacitance Ratio
Source abstract
Abstract
This paper presents a comparative analysis of distribution transformers with varying power ratings and insulation conditions using Frequency Domain Spectroscopy (FDS). The investigation was conducted both by comparing transformers with different performance ratings (from 100 to 1000 kVA) and insulation quality at a constant ambient temperature, and by evaluating insulation properties of a transformer across varying temperatures. The FDS method allows for separate assessments of oil quality and moisture content in solid insulation. An advantage of using capacitance measured by FDS for insulation assessment is its relatively lower sensitivity to temperature variations compared to the loss factor, a finding confirmed by temperature-effect analyses. However, assessing transformer insulation via capacitance measurements is influenced by the insulation’s geometric configuration, which depends on the transformer type and power rating. Therefore, when comparing the quality of insulating parts of transformers with different powers, it is recommended to compare the capacitance ratio depending on low frequencies against the capacitance at 50 Hz.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: High voltage insulation and dielectric phenomena · Power Transformer Diagnostics and Insulation · Electromagnetic Compatibility and Noise Suppression
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechatronics and Electronics, Faculty of Electrical Engineering and Information Technology, University of Zilina, Univerzitná 1, 010 01 Zilina, Slovakia
Faculty of Electrical Engineering and Informatics, Technical University of Kosice, Letna 9, 042 00 Kosice, Slovakia
Funding
Slovak Research and Development Agency
References (25)
Show source-provided references
1. Brandt, M. (2016, January 20–22). Identification failure of 3 MVA furnace transformer. Proceedings of the Conference DEMISEE 2016, Papradno, Slovakia.10.1109/DEMISEE.2016.7530472 ↗
2. An Improved Mathematical Model for Estimating Polarization Parameters of Transformer Oil-Paper Insulation10.1007/s42835-022-01019-0 ↗
3. Fernandez, I. (2022). The Need for Experimental and Numerical Analyses of Thermal Ageing in Power Transformers. Energies, 15.10.3390/en15176393 ↗
4. Hornak, J., Cernohous, J., Prosr, P., Rous, P., Trnka, P., Baran, A., and Hardon, S. (2023). Comprehensive Study of Polyurethane Potting Compounds Doped with Magnesium Oxide Nanoparticles. Polymers, 15.10.3390/polym15061532 ↗
5. Al-Ameri, S.M., Kamarudin, M.S., Yousof, M.F.M., Salem, A.A., Siada, A.A., and Mosaad, M.I. (2021). Interpretation of Frequency Response Analysis for Fault Detection in Power Transformers. Appl. Sci., 11.10.3390/app11072923 ↗
6. Peak efficiency and peak power point operation of wireless energy transfer (WET) system-analysis and verification10.1007/s00202-017-0658-4 ↗
7. Efficiency and Cost Based Multi-optimization and Thermal/Electromagnetic Analyses of 3-Phase Dry-Type Transformer10.1080/03772063.2020.1732841 ↗
8. Kudelcik, J., Hardon, S., Trnka, P., Michal, O., and Hornak, J. (2021). Dielectric Responses of Polyurethane/Zinc Oxide Blends for Dry-Type Cast Cold-Curing Resin Transformers. Polymers, 13.10.3390/polym13030375 ↗
9. Yoon, Y., Son, Y., Cho, J., Jang, S., Kim, Y.G., and Choi, S. (2021). High-Frequency Modeling of a Three-Winding Power Transformer Using Sweep Frequency Response Analysis. Energies, 14.10.3390/en14134009 ↗
10. Polarization and space charge behavior of unaged and electrically aged crosslinked polyethylene10.1109/94.868064 ↗
11. Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers10.1109/TDEI.2004.1266329 ↗
12. Neimanis, R. (2001). On Estimation of Moisture Content in Mass Impregnated Distribution Cables, Royal Institute of Technology Stockholm.
13. Artificial neural network based method for temperature correction in FDS measurement of transformer insulation10.1088/1361-6463/ab62c2 ↗
14. Koch, M., Krueger, M., and Puetter, M. (2011). Advanced Insulation Diagnostic by Dielectric Spectroscopy, Omicron Electronics Austria.
15. A Novel Curve Database for Moisture Evaluation of Transformer Oil-Immersed Cellulose Insulation Using FDS and Exponential Decay Model10.1109/ACCESS.2020.3027906 ↗
16. Koch, M., Tenbohlen, S., Kruger, M., and Kraetge, A. (2007, January 27–31). A Comparative Test and Consequent Improvements on Dielectric Response Methods. Proceedings of the XVth International Symposium on High Voltage Engineering, ISH, Ljubljana, Slovenia.
17. Koutras, K.N., Tegopoulos, S.N., Charalampakos, V.P., Kyritsis, A., Gonos, I.F., and Pyrgioti, E.C. (2022). Breakdown Performance and Partial Discharge Development in Transformer Oil-Based Metal Carbide Nanofluids. Nanomaterials, 12.10.3390/nano12020269 ↗
18. Saha, T.K., Middleton, R., and Thomas, A. (2004, January 26–29). Correlation between time and frequency domain polarisation measurements for transformer moisture assessment. Proceedings of the Australasian Universities Power Engineering Conference (AUPEC), Brisbane, Australia.
19. (2025, March 25). Manual Megger IDAX 350. Available online: https://www.manua.ls/megger/idax-350/manual.
20. Koch, M., and Kruger, M. (2008, January 1–2). Moisture Determination by Improved On-Site Diagnostics. Proceedings of the TechCon Asia Pacific, Sydney, Australia.
21. Takacs, K., and Frivaldsky, M. (2022, January 23–26). Simulation design of residential smartgrid based on solid-state transformer. Proceedings of the 2022 ELEKTRO, Krakow, Poland.10.1109/ELEKTRO53996.2022.9803792 ↗
22. Rogalski, P. (2020, January 9–13). Study of Power Transformer Insulation Model. The X-Y Model of Oil Impregnated Pressboard—Water Nanodrops—Insulating Oil Composite. Proceedings of the 10th IEEE International Conference on Nanomaterials—Applications and Properties (NAP), Sumy, Ukraine.10.1109/NAP51477.2020.9309687 ↗
23. Normalization for FDS of Transformer Insulation Considering the Synergistic Effect Generated by Temperature and Moisture10.1109/ACCESS.2020.3036418 ↗
24. Temperature Effect on the Structure of Transformer Oil Based Magnetic Fluids Using Acoustic Spectroscopy10.12693/APhysPolA.121.1169 ↗
25. Moisture estimation for oil-immersed bushing based on FDS method: At a reference temperature10.1049/iet-gtd.2017.1591 ↗