Experimental Investigation and Modelling of the Incipient Fault of Low-Voltage XLPE Cables in Wet Environments
Source abstract
Abstract
The study of incipient faults due to insulation defects in cables is crucial for preventing electrical fires and ensuring personal safety. However, research on incipient faults in low-voltage cables remains relatively underexplored compared to that on medium-voltage cables. This paper focuses on low-voltage cross-linked polyethylene (XLPE) cables and investigates the changes in voltage and current caused by insulation defects in different wet conditions. The main findings are that the voltage applied to the cable with defective insulation shows sub-cycle disturbances that become more frequent. The current in the cable conductor shows a pulsed shape, coincident with the voltage disturbances. Over time, the sub-cycle disturbances gradually disappear, instead, the steady-state leakage current emerges. The wet conditions affect waveforms of the voltage/current disturbance and the frequency of occurrence. The findings provide detailed and unique characteristics of the voltage and current during the cable incipient fault, which are different from those of the incipient fault in the medium-voltage cables. The simulation and analysis support the experimental results. Based on the experimental results, a model is developed for further research on LV-cable incipient fault detection and protection.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: High voltage insulation and dielectric phenomena · Electrical Fault Detection and Protection · Thermal Analysis in Power Transmission
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400044, China
Funding
National Natural Science Foundation of China
References (25)
Show source-provided references
1. Corrosion in Low-Voltage Distribution Networks and Perspectives for Online Condition Monitoring10.1109/TPWRD.2019.2903730 ↗
2. Incipient Fault Detection in Power Distribution Networks: Review, Analysis, Challenges, and Future Directions10.1109/ACCESS.2024.3443252 ↗
3. Research on Electrical Fires: The State of the Art10.3801/IAFSS.FSS.9-3 ↗
4. A Survey of Electrical Fire Causes Assessment Technology10.1109/ACCESS.2024.3437175 ↗
5. Fire Department of the Ministry of Public Security (2018). China Fire Yearbook 2018.
6. High frequency modeling of a shielded four-core low voltage underground power cable10.1109/TDEI.2015.7076759 ↗
7. Intermittent arcing fault on underground low-voltage cables10.1109/TPWRD.2003.822979 ↗
8. Detection of Incipient Faults in Distribution Underground Cables10.1109/TPWRD.2010.2041373 ↗
9. A Novel Fault Leakage Current Detection Method With Protection Deadzone Elimination
10. Zhang, M., Qin, P., Chen, Y., Jia, H., Wang, Z., and Deng, W. (2021, January 8–9). Study on the Detection Method of Leakage in TN-C Area of Low-voltage Distribution Network. Proceedings of the 2021 International Conference on Power System Technology (POWERCON), Haikou, China.10.1109/POWERCON53785.2021.9697410 ↗
11. Ground-Fault Loop Impedance Calculations in Low-Voltage Single-Phase Systems10.1109/TIA.2013.2272285 ↗
12. Data-Based Line Trip Fault Prediction in Power Systems Using LSTM Networks and SVM10.1109/ACCESS.2017.2785763 ↗
13. Haleem, A.M.I., Sharma, M., Sajan, K.S., and Babu, K.D. (2018, January 15). A Comparative Review of Fault Location/Identification Methods in Distribution Networks. Proceedings of the 2018 1st International Conference on Advanced Research in Engineering Sciences (ARES), Dubai, United Arab Emirates.10.1109/ARESX.2018.8723300 ↗
14. Analysis of Characteristic Quantity of Incipient Fault of Medium Voltage Cable Joints in Water-logged Environment Based on Fluid Characteristics10.1109/TIM.2024.3427810 ↗
15. Dynamic Resistance Characteristics of an Incipient Fault of a Medium-Voltage Cable Joint in a Water-Logged Environment
16. Evolution Process and Characteristics of Medium Voltage Cable Joints’ Incipient Faults in Humid Environment
17. Experimental research on incipient fault voltage disturbance model of power cable insulation10.1016/j.ijepes.2022.108687 ↗
18. Modeling of Internal Multiform Intermittent Arc Fault for 10kV XLPE Cable
19. Incipient Faults Monitoring in Underground Medium Voltage Cables of Distribution Systems Based on a Two-Step Strategy10.1109/TPWRD.2019.2917268 ↗
20. Deng, J., Zhang, W., and Yang, X. (2019). Recognition and Classification of Incipient Cable Failures Based on Variational Mode Decomposition and a Convolutional Neural Network. Energies, 12.10.3390/en12102005 ↗
21. Liu, N., Fan, B., Xiao, X., and Yang, X. (2019). Cable Incipient Fault Identification with a Sparse Autoencoder and a Deep Belief Network. Energies, 12.10.3390/en12183424 ↗
22. Cable incipient fault identification using restricted Boltzmann machine and stacked autoencoder10.1049/iet-gtd.2019.0743 ↗
23. Xie, X. (2023). Study on Early Fault Modeling and Identification Methods for Low-Voltage Single-Core Cables. [Ph.D. Thesis, Chongqing University].
24. Fault Development in Wet, Low Voltage, Oil-Impregnated Paper Insulated Cables10.1109/TDEI.2008.4483468 ↗
25. Fault development upon water ingress in damaged low voltage underground power cables with polymer insulation10.1109/TDEI.2017.005953 ↗