journal article·2025-03-27Open access

Enhanced Force Systems for Efficient Maxillary Anterior Diastema Closure Using Clear Aligners: Evaluation of Attachments and Enhanced Structural Modifications

Min-Jeong Jee, Yong-Il Kim, Sung-Hun Kim, Seong-Sik Kim, Soo-Byung Park, Youn-Kyung Choi

Applied Sciences· Volume 15· Issue 7

Abstract

This study evaluates the biomechanical efficacy of clear aligners in closing anterior maxillary diastemas using enhanced force systems. While clear aligners offer esthetic and functional benefits, their predictability in controlling bodily movement and torque remains limited. This research investigates the effects of structural modifications, such as the addition of flowable resin to interdental embrasures and intrusive force application, on the force and moment characteristics during mesial bodily movement of maxillary central incisors. Experiments were conducted using 3D-printed maxillary models with a 6-axis force/torque sensor under controlled conditions. Four experimental groups were tested: Group 1 (0.3 mm mesial bodily shift), Group 2 (0.3 mm mesial shift + 0.1 mm intrusion), Group 3 (0.3 mm mesial shift with resin reinforcement), and Group 4 (0.3 mm mesial shift + 0.1 mm intrusion with resin reinforcement). The results showed that Groups 1 and 3 exhibited extrusive forces, while Groups 2 and 4 exhibited intrusive movement with minimized extrusion. Resin reinforcement significantly increased mesiodistal force application and reduced unwanted tipping and rotational moments, improving bodily movement efficiency. The addition of intrusive movement minimized extrusive forces but introduced a minor lingual inclination. The combination of both modifications provided the most controlled and efficient tooth movement. These results suggest that modifying clear aligners with localized structural enhancements can improve treatment predictability and efficiency. Clinically, the application of flowable resin enhancements offers a simple and effective approach to optimizing clear aligner therapy.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Nasal Surgery and Airway Studies · Temporomandibular Joint Disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthodontics, Dental Research Institute, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea

Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea

Funding

Dental Research Institute

References (33)

Show source-provided references
1. Evaluation of Invisalign treatment effectiveness and efficiency compared with conventional fixed appliances using the Peer Assessment Rating index10.1016/j.ajodo.2016.06.041 ↗
2. Comparison of pain perception, anxiety, and impacts on oral health related quality of life between patients receiving clear aligners and fixed appliances during the initial stage of orthodontic treatment10.1093/ejo/cjaa037 ↗
3. The dynamic of the oral microbicome and oral health among patients receiving clear aligner orthodontic treatment10.1111/odi.13175 ↗
4. Effectiveness of clear aligner therapy for orthodontic treatment: A systematic review10.1111/ocr.12353 ↗
5. Clinical effectiveness of Invisalign® orthodontic treatment: A systematic review10.1186/s40510-018-0235-z ↗
6. Forces and moments generated by removable thermoplastic aligners: Incisor torque, premolar derotation, and molar distalization10.1016/j.ajodo.2014.03.015 ↗
7. Open gingival embrasures after orthodontic treatment in adults: Prevalence and etiology10.1067/mod.2001.114831 ↗
8. Initial forces acting on the maxillary teeth with aligner activation of canine distalization on the basis of different initial canine tips in vitro10.1016/j.ajodo.2022.10.026 ↗
9. Effects of Attachment of Plastic Aligner in Closing of Diastema of Maxillary Dentition by Finite Element Method
10. Risk factors associated with open gingival embrasures after orthodontic treatment10.2319/061917-399.12 ↗
11. The effect of enhanced structure in the posterior segment of clear aligners during anterior retraction: A three-dimensional finite element and experimental model analysis10.1186/s40510-023-00502-2 ↗
12. Effects of mechanical properties of thermoplastic materials on the initial force of thermoplastic appliances10.2319/052512-432.1 ↗
13. Influence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping10.1016/j.ajodo.2008.12.015 ↗
14. Three-dimensional orthodontic force measurements10.1016/j.ajodo.2009.02.025 ↗
15. Advances in orthodontic clear aligner materials
16. Choi, Y.-K., Kim, S.-H., Park, H.R., Kim, S.-S., and Kim, Y.-I. (2024). Analysis of the Forces and Moments in Canine Bodily Movement with Different Clear Aligners’ Extraction Space Designs. Appl. Sci., 14.10.3390/app14177619 ↗
17. Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method10.4041/kjod24.016 ↗
18. Clear aligners: A network and bibliometric analysis of 50 pivotal articles
19. Cheng, Y., Liu, X., Chen, X., Li, X., Fang, S., Wang, W., Ma, Y., and Jin, Z. (2022). The three-dimensional displacement tendency of teeth-depending on incisor torque compensation with clear aligners of different thicknesses in cases of extraction: A finite element study. BMC Oral Health, 22.10.1186/s12903-022-02521-7 ↗
20. Pendulum and modified pendulum appliances for maxillary molar distalization in Class II malocclusion a systematic review10.1080/00016357.2017.1324636 ↗
21. Maxillary molar distalization with aligners in adult patients: A multicenter retrospective study10.1186/s40510-016-0126-0 ↗
22. Caruso, S., Nota, A., Ehsani, S., Maddalone, E., Ojima, K., and Tecco, S. (2019). Impact of molar teeth distalization with clear aligners on occlusal vertical dimension: A retrospective study. BMC Oral Health, 19.10.1186/s12903-019-0880-8 ↗
23. Nanda, R.S., and Tosun, Y.S. (2010). Biomechanics in Orthodontics, Princ Pract. Hanover Park Quintessence Publ. Co.
24. Clinical effectiveness of clear aligner treatment compared to fixed appliance treatment: An overview of systematic reviews10.1007/s00784-021-04361-1 ↗
25. Elshazly, T.M., Salvatori, D., Elattar, H., Bourauel, C., and Keilg, L. (2023). Effect of trimming line design and edge extension of orthodontic aligners on force transmission: A 3D finite element study. J. Mech. Behav. Biomed. Mater., 140.10.1016/j.jmbbm.2023.105741 ↗
26. The effect of gingival margin design on the retention of thermoformed aligners
27. Effect of trimming line design and edge extension of orthodontic aligners on force transmission: An in vitro study10.1016/j.jdent.2022.104276 ↗
28. Initial force systems during bodily tooth movement with plastic aligners and composite attachments: A three-dimensional finite element analysis10.2319/050714-330.1 ↗
29. Biomechanical analysis of miniscrew-assisted molar distalization with clear aligners: A three-dimensional finite element study10.1093/ejo/cjad077 ↗
30. The stress and deformation effect of novel rapid maxillary expanders by finite element analysis10.1007/s40846-022-00741-4 ↗
31. Efficacy of clear aligners in controlling orthodontic tooth movement: A systematic review10.2319/061614-436.1 ↗
32. Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An in vitro study10.4041/kjod.2021.51.2.135 ↗
33. Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: A prospective clinical study10.1186/s40510-019-0289-6 ↗