Optimization Control of Sub-Synchronous Oscillations in Doubly Fed Generators with Wind Turbines Using the Genetic Algorithm
Source abstract
Abstract
The sub-synchronous oscillation accident of large-scale doubly fed wind turbines connected to a grid through series compensation has caused a serious impact on the power system. By optimizing the parameters of the doubly fed wind turbines control system, the system impedance can be effectively improved to solve the problem of sub-synchronous oscillation. However, owing to the complexity of a grid-connected system of doubly fed generators connected to wind turbines and the influence of the time-varying oscillation characteristics of the system, it is often difficult to achieve a successful suppression. To solve this problem, this paper proposes an optimized additional damping method for the rotor- and grid-side controllers, which can achieve efficient suppression of the sub-synchronous oscillation. The parameters of the proposed additional damping method are optimized for all variable operation conditions using a genetic algorithm under the established frequency–domain impedance model. The detailed time–domain simulation model was constructed with the RTLAB platform to verify the proposed method. The experimental results show that the optimized control strategy can effectively and quickly suppress the sub-synchronous oscillation under different operating conditions, and the amplitude suppression rate reached 85.99%, which effectively improved the grid-connected stability of the wind turbines.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Microgrid Control and Optimization · Islanding Detection in Power Systems · Wind Turbine Control Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Mechanical and Electrical Engineering, China University of Mining & Technology-Beijing, Beijing 100083, China
Funding
Beijing Natural Science Foundation · National Natural Science Foundation of China · Fundamental Research Funds for the Central Universities
References (23)
Show source-provided references
1. (2024, December 10). Global Wind Energy Report 2024. Available online: https://gwec.net/global-wind-report-2024/.10.1016/j.focat.2024.07.012 ↗
2. IRENA (2023). Renewable Energy Statistics 2023, International Renewable Energy Agency.
3. Liu, Y., Wang, Z., Shen, H., Wei, Q., Li, Q., and Zhang, X. (2023, January 14–15). The research of the superconducting magnetic energy storage model based on the real time digital system. Proceedings of the 12th International Conference on Renewable Power Generation (RPG 2023), Shanghai, China.10.1049/icp.2023.2258 ↗
4. Impact of Shunt reactor to DFIG Connected to Series-Compensated Power System on Sub-synchronous Oscillation Characteristics10.1051/matecconf/201817302030 ↗
5. Variable Pitch Active Disturbance Rejection Control of Wind Turbines Based on BP Neural Network PID10.1109/ACCESS.2020.2987912 ↗
6. Dong, L., Kong, J., Feng, J., and Zhang, Y. (2019, January 3–6). Sub-synchronous Resonance Mitigation for Series Compensation Transmission System of DFIG Based on PR Control. Proceedings of the 2019 IEEE 10th International Symposium on Power Electronics for Distributed Generation Systems (PEDG), Xi’an, China.10.1109/PEDG.2019.8807674 ↗
7. Overview of Stability Analysis of Grid-Connected Inverters Using Impedance Analysis Method
8. Impedance-based stability criterion for grid-connected inverters10.1109/TPEL.2011.2136439 ↗
9. Zhen, Z., Du, W., and Wang, H. (2019). Equivalence Proof of the Complex Torque Coefficient Method and Open-Loop Mode Stability Criterion in Strong Modal Coupling Phenomenon. Proc. Chin. Soc. Electr. Eng., 39.
10. Wang, Y., Yu, H., Liu, Z., Ma, Y., Zhao, G., and Deng, Z. (2019, January 11–14). Broadband Sub-synchronous Signal Extraction and Analysis of the Key Parameters. Proceedings of the 2019 4th IEEE Workshop on the Electronic Grid (eGRID), Xiamen, China.10.1109/eGRID48402.2019.9092671 ↗
11. Analysis of D-Q small-signal impedance of grid-tied inverters10.1109/TPEL.2015.2398192 ↗
12. Characteristic analysis of sub-synchronous resonance in practical wind farms connected to series-compensated transmissions10.1109/TEC.2017.2676024 ↗
13. Risk Assessment of Sub/Super-Synchronous Oscillation for Wind Power Based on Hardware-in-the-Loop Testing
14. Sequence impedance modeling and analysis of type-III wind turbines10.1109/TEC.2017.2763585 ↗
15. Tian, Y., Liu, Y., Xiao, Z., Wang, Z., Geng, Y., and Zhao, D. (2023, January 28–30). Research on Construction Scheme of New Generation Centralized Control Station Intelligent Monitoring System. Proceedings of the 2023 3rd International Conference on Energy Engineering and Power Systems (EEPS), Dali, China.10.1109/EEPS58791.2023.10256992 ↗
16. Study on Sub-synchronous Oscillation in Power Systems Caused by Wind Farms Connected to the Grid Based on Improved Complex Torque Coefficient Method
17. Impedance-model-based SSR analysis for type 3 wind generator and series-compensated network10.1109/TEC.2012.2211019 ↗
18. Research on the Impact on Sub-synchronous Resonance Risk from DFIG Number and Series-compensated Degree10.1088/1742-6596/1087/4/042075 ↗
19. Chi, Y., Liu, Y., Wang, W., and Dai, H. (2006, January 22–26). Voltage Stability Analysis of Wind Farm Integration into Transmission Network. Proceedings of the 2006 International Conference on Power System Technology, Chongqing, China.10.1109/ICPST.2006.321661 ↗
20. Ghennam, T., Berkouk, E.M., and Francois, B. (2007, January 2–5). DC-link voltage balancing algorithm using a space-vector hysteresis current control for three-level VSI applied for wind conversion system. Proceedings of the 2007 European Conference on Power Electronics and Applications, Aalborg, Denmark.10.1109/EPE.2007.4417514 ↗
21. Impedance Modelling in Synchronous Reference Frame and Stability Discrimination Method for Grid-Connected New Energy Generation Systems
22. Impedance Modelling and Characteristic Analysis of Three-Phase LCL Grid-Connected Inverter
23. Mitigation of Sub-synchronous Resonance in Series-Compensated DFIG Wind Farm Using Active Disturbance Rejection Control10.1109/ACCESS.2019.2919561 ↗