Evidence-Based Investigation of Coronary Calcium Score in Cardiac Computed Tomography
Source abstract
Abstract
This study aimed to verify whether increased body mass index (BMI) increases the noise in computed tomography (CT) images due to heightened effective thickness, impacting calcium scores. Calcium scores were measured in 30 sets of images from normal weight patients. Calcium scores were also measured in 30 sets of images from hypothetical overweight and obese patients, generated by extracting the noise from overweight and obese patients, respectively, and inserting it into the images of normal weight patients. In addition, a phantom study was performed using three calcium phantoms with intensities below the threshold of 130 Hounsfield units and three calcium phantoms with intensities above this threshold. Calcium scores were measured in the absence and presence of a bolus at the heart level to simulate an obese patient. All calcium scores were measured by three radiologists. In the patient study, the total calcium scores of the hypothetical overweight and hypothetical obese groups were 14.93% (p = 0.014) and 22.19% (p = 0.012) higher than those of the normal weight group. In the phantom study, the total calcium score of the six calcium phantoms without a bolus was 1.61% higher at a tube voltage of 120 kV than at 100 kV, and 12.06% higher at a slice thickness of 1 mm than at 3 mm. The total calcium score of the six calcium phantoms with a bolus was 0.13% higher at a tube voltage of 120 kV than at 100 kV, and 14.76% higher at a slice thickness of 1 mm than at 3 mm. These results can be used as a reference to train automated calcium scoring programs on effective thickness through deep learning to reduce calcium score errors caused by increased BMI.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Cardiac Imaging and Diagnostics · Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Diagnostic Radiology, Severance Hospital, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
Department of Biomedical Engineering, Eulji University, 553, Sanseong-daero, Sujeong-gu, Seongnam-si 13135, Republic of Korea
Department of Radiological Science, Gachon University, 191, Hambakmoe-ro, Yeonsu-gu, Incheon 21936, Republic of Korea
Funding
National Foundation of Korea
References (38)
Show source-provided references
1. Prediction of subsequent osteoporotic vertebral compression fracture on CT radiography via deep learning10.1002/VIW.20220012 ↗
2. In vivo CT imaging tracking of stem cells labeled with Au nanoparticles10.1002/VIW.20200119 ↗
3. Coronary artery calcium scoring in cardiovascular risk assessment10.1111/j.1755-5922.2010.00172.x ↗
4. Multi-detector row CT systems and image-reconstruction techniques10.1148/radiol.2353040037 ↗
5. Dual-source CT cardiac imaging: Initial experience10.1007/s00330-006-0298-y ↗
6. Strategies for reduction of radiation dose in cardiac multislice CT10.1007/s00330-007-0584-3 ↗
7. Coronary artery calcium and its relationship to coronary artery disease10.1016/S0733-8651(03)00088-2 ↗
8. Bernardini, F., Gelfusa, M., Celeski, M., Coletti, F., Nusca, A., De Stefano, D., Piccirillo, F., Mangiacapra, F., Gallo, P., and Cammalleri, V. (2023). Beyond the calcium score: What additional information from a CT scan can assist in cardiovascular risk assessment?. Appl. Sci., 13.10.3390/app13010241 ↗
9. The National Lipid Association scientific statement on coronary artery calcium scoring to guide preventive strategies for ASCVD risk reduction10.1016/j.jacl.2020.12.005 ↗
10. Major global coronary artery calcium guidelines10.1016/j.jcmg.2022.06.018 ↗
11. Coronary calcium as a predictor of coronary events in four racial or ethnic groups10.1056/NEJMoa072100 ↗
12. Long-term prognosis after coronary artery calcification testing in asymptomatic patients: A cohort study10.7326/M14-0612 ↗
13. Guideline for minimizing radiation exposure during acquisition of coronary artery calcium scans with the use of multidetector computed tomography: A report by the society for atherosclerosis imaging and prevention tomographic imaging and prevention councils in collaboration with the society of cardiovascular computed tomography10.1016/j.jcct.2011.01.003 ↗
14. Hoori, A., Al-Kindi, S., Hu, T., Song, Y., Wu, H., Lee, J., Tashtish, N., Fu, P., Gilkeson, R., and Rajagopalan, S. (2024). Enhancing cardiovascular risk prediction through AI-enabled calcium-omics. Sci. Rep., 14.10.1038/s41598-024-60584-8 ↗
15. Practical Poissonian-Gaussian noise modeling and fitting for single-image raw-data10.1109/TIP.2008.2001399 ↗
16. Noise suppression in scatter correction for cone-beam CT10.1118/1.3063001 ↗
17. Lancaster, J., and Hasegawa, B. (2016). Fundamental Mathematics and Physics of Medical Imaging, CRC Press, Taylor & Francis Group.10.1201/9781315368214 ↗
18. Association of hypertension, diabetes, dyslipidemia, and metabolic syndrome with obesity: Findings from the National Health and Nutrition Examination Survey, 1999 to 200410.1016/j.jamcollsurg.2008.08.022 ↗
19. Metabolically-healthy obesity and coronary artery calcification10.1016/j.jacc.2014.03.042 ↗
20. Association of body mass index with coronary artery calcium and subsequent cardiovascular mortality: The Coronary Artery Calcium Consortium10.1161/CIRCIMAGING.119.009495 ↗
21. Perone, F., Pingitore, A., Conte, E., Halasz, G., Ambrosetti, M., Peruzzi, M., and Cavarretta, E. (2023). Obesity and cardiovascular risk: Systematic intervention is the key for prevention. Healthcare, 11.10.3390/healthcare11060902 ↗
22. Noise parameter mismatch in variance stabilization, with an application to Poisson-Gaussian noise estimation10.1109/TIP.2014.2363735 ↗
23. Single-image noise level estimation for blind denoising10.1109/TIP.2013.2283400 ↗
24. Estimation of the noise level function based on a nonparametric detection of homogeneous image regions10.1137/15M1012682 ↗
25. Lee, S., Lee, M.S., and Kang, M.G. (2018). Poisson-Gaussian noise analysis and estimation for low-dose x-ray images in the NSCT domain. Sensors, 18.10.3390/s18041019 ↗
26. A new measure of rank correlation10.1093/biomet/30.1-2.81 ↗
27. The treatment of ties in ranking problems10.1093/biomet/33.3.239 ↗
28. A first-order primal-dual algorithm for convex problems with applications to imaging10.1007/s10851-010-0251-1 ↗
29. Using the coronary artery calcium score to predict coronary heart disease events: A systematic review and meta-analysis10.1001/archinte.164.12.1285 ↗
30. The future of concurrent automated coronary artery calcium scoring on screening low-dose computed tomography
31. Automated coronary calcium scoring using deep learning with multicenter external validation10.1038/s41746-021-00460-1 ↗
32. Choi, J.H., Cha, M.J., Cho, I., Kim, W.D., Ha, Y., Choi, H., Lee, S.H., You, S.C., and Chang, J.S. (2022). Validation of deep learning-based fully automated coronary artery calcium scoring using non-ECG-gated chest CT in patients with cancer. Front. Oncol., 12.10.3389/fonc.2022.989250 ↗
33. Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults10.1007/s00330-012-2424-3 ↗
34. Automated attenuation-based selection of tube voltage and tube current for coronary CT angiography: Reduction of radiation exposure versus a BMI-based strategy with an expert investigator10.1016/j.jcct.2013.08.010 ↗
35. Achieving consistent image quality and overall radiation dose reduction for coronary CT angiography with body mass index-dependent tube voltage and tube current selection10.1016/j.crad.2014.04.016 ↗
36. Validation and prognosis of coronary artery calcium scoring in nontriggered thoracic computed tomography: Systematic review and meta-analysis10.1161/CIRCIMAGING.113.000092 ↗
37. Optimized categorization algorithm of coronary artery calcification score on non-gated chest low-dose CT screening using iterative model reconstruction technique10.1016/j.clinimag.2018.08.015 ↗
38. Evaluation of fully automated commercial software for Agatston calcium scoring on non-ECG-gated low-dose chest CT with different slice thickness10.1007/s00330-022-09143-1 ↗