Experimental Investigation on Structural Performance Enhancement of Brick Masonry Member by Internal Reinforcement
Source abstract
Abstract
This study focused on perforated bricks, and the structural performance enhancement of brick members by internal reinforcement was experimentally investigated. As a new reinforcing material, screw iron (SI) rods were selected for the internal reinforcement, and they were inserted into the perforated brick. To investigate the most-effective reinforcing method as well as to understand the fundamental structural behaviors, four specimens with different variables were fabricated, and three-point bending tests were carried out. From the experiments, it was found that the maximum strength of the specimen increased by more than two times with internal reinforcement. The internal reinforcement, fixed by nuts at both ends of the specimen to enhance integrity, increased the maximum strength by nine times. Moreover, the deformation capacities of the specimens were also greatly enhanced. The case where the internal SI rods were fixed by nuts without mortar also showed a similar structural performance to the case with mortar. The estimation methods of the maximum strength of the specimens were also discussed, and they showed reasonable agreement with the test results. It was proved that the proposed material and methods enabled effective utilization of the internal reinforcement, and they could contribute to the improvement of structural performances in masonry construction.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Masonry and Concrete Structural Analysis · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Architecture, School of Science and Technology, Meiji University, Kanagawa, Kawasaki 2148517, Japan
Department of Architecture, Faculty of Science and Technology, Shizuoka Institute of Science and Technology, Fukuroi 4378555, Japan
Department of Architecture, Graduate School and Faculty of Engineering, Osaka Institute of Technology, Osaka 5358585, Japan
References (54)
Show source-provided references
1. (2023, April 01). Meguro & Numada Lab of the University of Tokyo. Available online: http://risk-mg.iis.u-tokyo.ac.jp/index.html.
2. Steel frames with brickwork and concrete infilling
3. Lateral stiffness of infilled frames10.1061/JSDEAG.0000849 ↗
4. Behaviour of the square infilled frames10.1061/JSDEAG.0001387 ↗
5. A method of analysis for infill frames
6. On the stiffness and strength of infilled frames
7. Hendry, A.W. (1998). Structural Masonry, Macmillan.10.1007/978-1-349-14827-1 ↗
8. Applied Technology Council (ATC) (1998). Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings, FEMA 306.
9. Paulay, T., and Priestley, M.J.N. (1992). Seismic Design of Reinforced Concrete and Masonry Buildings, John Wiley & Sons, Inc.10.1002/9780470172841 ↗
10. Behaviour and analysis of masonry-infilled frames10.1002/pse.122 ↗
11. Prediction of the additional shear action on frame memebers due to infills10.1007/s10518-014-9668-z ↗
12. Experimental Study on Lateral Strength Evaluation of Unreinforced Masonry-Infilled RC Frame10.1193/100714EQS152M ↗
13. Seismic performance of older R/C frame structures accounting for infills-induced shear failure of columns10.1016/j.engstruct.2016.05.010 ↗
14. Experimental evaluation of the in-plane behaviour of masonry wall infilled RC frames10.1007/s10518-017-0139-1 ↗
15. Local effects on RC frames induced by AAC masonry infills through FEM simulation of in-plane tests10.1007/s10518-018-0353-5 ↗
16. Experimental investigation of influences of several parameters on seismic capacity of masonry infilled reinforced concrete frame10.1016/j.engstruct.2019.03.020 ↗
17. Applied Technology Council (ATC) (2000). Prestandard and Commentary for the Seismic Rehabilitation of Buildings, FEMA 356.
18. American Society of Civil Engineers (2007). Seismic Rehabilitation of Existing Buildings, ASCE Publications [ASCE/SEI 41-06].
19. Stavridis, A., and Shing, B. (2012, January 24–28). Simplified modeling of masonry-infilled RC frames subjected to seismic loads. Proceedings of the 15th World Conference on Earthquake Engineering, Lisbon, Portugal.
20. A simplified evaluation method of skeleton curve for RC frame with URM infill
21. Experimental observations on the inplane behaviour of masonry wall infilled RC frames; focusing on deformation limits and backbone curve10.1007/s10518-017-0248-x ↗
22. Akhoundi, F., Vasconcelos, G., Lourenco, P., and Silva, L.C. (2016, January 26–30). Out-of-Plane Response of Masonry Infilled RC Frames: Effect of Workmanship and Opening. Proceedings of the 16th International Brick and Block Masonry Conference, Padova, Italy.10.1201/b21889-143 ↗
23. Out-of-Plane Proof Testing of Masonry Infill Walls10.1016/j.istruc.2018.07.003 ↗
24. Shake Table Tests for the Seismic Assessment of Hollow Brick Internal Partitions10.1016/j.engstruct.2014.04.044 ↗
25. Yu, J.H., and Park, J.H. (2020). Investigation of Steel Fiber-Reinforced Mortar Overlay for Strengthening Masonry Walls by Prism Tests. Appl. Sci., 10.10.3390/app10186395 ↗
26. Flexural behavior of reinforced concrete beams using waste marble powder towards application of sustainable concrete10.3389/fmats.2022.1068791 ↗
27. Out-of-plane bending of FRP-reinforced masonry walls10.1016/S0266-3538(98)00007-4 ↗
28. Modeling of reinforced masonry elements10.1016/S0020-7683(00)00297-3 ↗
29. ElGawady, M., Lestuzzi, P., and Badoux, M. (2004, January 4–7). A review of conventional seismic retrofitting techniques for URM. Proceedings of the 13th International Brick and Block Masonry Conference, Amsterdam, The Netherlands.
30. Seki, M., Popa, V., Lozinca, E., Dutu, A., and Papurcu, A. (2018, January 18–21). Experimental Study on Retrofit Technologies for Rc Frames with Infilled Brick Masonry Walls in Developing Countries. Proceedings of the 16th European Conference on Earthquake Engineering, Thessaloniki, Greece.
31. Out-of-Plane Behavior of Reinforced Masonry Walls: Experimental and Numerical Study10.1016/j.compositesb.2017.07.006 ↗
32. Alwashali, H., Sen, D., Maeda, M., and Seki, M. (October, January 26). Advantages and limitations of retrofitting masonry infilled RC Frames by Ferro-cement based on experimental observations. Proceedings of the 17th World Conference on Earthquake Engineering, Sendai, Japan.
33. Furtado, A., Rodrigues, H., Arêde, A., and Varum, H. (2020). Impact of the Textile Mesh on the Efficiency of TRM Strengthening Solutions to Improve the Infill Walls Out-of-Plane Behaviour. Appl. Sci., 10.10.3390/app10238745 ↗
34. Scamardo, M., Cattaneo, S., Biolzi, L., and Vafa, N. (2022). Parametric Analyses of the Response of Masonry Walls with Reinforced Plaster. Appl. Sci., 12.10.3390/app12105090 ↗
35. Seismic Resistance of Brick Masonry Walls10.5459/bnzsee.7.4.167-187 ↗
36. Reinforced masonry walls under blast loading10.1016/S0020-7403(02)00014-0 ↗
37. Haach, V.G., Vasconcelos, G., and Lourenco, P.B. (2014, January 7–9). Study of the behaviour of reinforced masonry wallets subjected to diagonal compression through numerical modeling. Proceedings of the 9th International Masonry Conference, Guimarães, Portugal.
38. Haile, F., Corradi, M., and Adkins, J. (2022, January 25–27). Titanium rods with high mechanical properies were embedded into the horizontal mortar bed joint. Proceedings of the Conservation of Architectural Heritage (CAH)—6th Edition, Sicily, Italy.
39. Strengthening of historic masonry structures with composite materials10.1007/BF02524777 ↗
40. Experimental investigations on masonry structures using external prestressing techniques for improving seismic performance10.1016/j.engstruct.2012.04.029 ↗
41. In-plane seismic performance of masonry wall retrofitted with prestressed steel-bar truss
42. Experimental study of prestressed masonry flexural elements10.1061/(ASCE)0733-9445(1999)125:3(245) ↗
43. Prestressed masonry10.1002/1528-2716(200007/09)2:3<304::AID-PSE37>3.0.CO;2-0 ↗
44. Post-tensioned masonry: State of the art10.1002/1528-2716(200007/09)2:3<311::AID-PSE46>3.0.CO;2-2 ↗
45. Shaketable testing of rectangular post-tensioned concrete masonry walls
46. Cyclic shear behavior of masonry walls strengthened with prestressed steel bars and glass fiber grids10.1016/j.compstruct.2020.111961 ↗
47. (2002). Building Code Requirements for Masonry Structures. Standard No. ACI 530-02/ASCE 5-02/TMS 402-02. Available online: https://engineering.purdue.edu/~ramirez/CE479/FALL05/MasonryBuildingCode1-3-02.pdf.
48. (2001). Post-Tensioned Concrete Masonry Wall Design. Standard No. TEK 14-20A.
49. Jin, K., Masuda, T., Habara, Y., and Tomizawa, T. (2022). Summaries of Technical Papers of Annual Meeting, Architectural Institute of Japan (AIJ). (In Japanese).
50. Detailed evaluation of the ultimate flexural states of beams in unbonded precast prestressed concrete frames10.1007/s10518-018-0504-8 ↗
51. Direct evaluation method for load-deformation curve of precast prestressed concrete frame with different tendon forces10.1007/s10518-021-01109-w ↗
52. Jin, K., Ota, R., Hao, L., and Kitayama, K. (2023). Evaluation Method for Ultimate Flexural State of Prestressed Precast Reinforced Concrete Beam–Column Connection with Debonded Partial Tendon. Appl. Sci., 13.10.3390/app13052843 ↗
53. Shear Capacity of Precast Prestressed Concrete Beam-Column Joint Assembled by Unbonded Tendon
54. Architectural Institute of Japan (2018). AIJ Standard for Structural Calculation of Reinforced Concrete Structures, Architectural Institute of Japan (AIJ).