journal article·2023-03-31Open access

Wear Effect on the Contact between a Metallic Pin and a Rotating Polymeric Specimen

Annamaria Visco, Gabriella Epasto, Fabio Giudice, Cristina Scolaro, Andrea Sili

Applied Sciences· Volume 13· Issue 7

Abstract

Debris formation is a crucial aspect that determines the lifespan of prosthetic joints. The wearing contact between ultra-high molecular weight polyethylene (UHMWPE) and a Ti alloy surface has been studied in the literature. However, when measuring mass loss, potential errors can arise due to the very small values involved (on the order of some units of 0.1 mg in experiments lasting several hours) and be caused by the absorption of humidity in the specimen, in addition to the lack of accuracy typical of weight scales. These errors can hardly be avoided, but accurate cleaning and drying processes can minimize them. With these premises, the present work aims to determine, by pin-on-disc test, the wear effect in the UHMWPE rotating sheet and Ti6Al4V pin produced by Electron Beam Melting (EBM) under dry and lubricated conditions. The morphology of the worn surface was documented by optical microscopy, and the volume loss of both the rotating specimens and the pin was accurately calculated through the detection of the wear track observed by optical microscopy. In particular, the present work proposes a method for directly determining the volume loss of the polymer to compare it with that obtained with the weight measurement. For both procedures, the uncertainty in evaluating the specific wear rate was analyzed, demonstrating that volume measurement allows for avoiding any possible error associated with weighing the polymeric specimens.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Tribology and Wear Analysis · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Engineering, University of Messina, 98166 Messina, Italy

Institute for Polymers, Composites and Biomaterials, CNR-IPCB, 95126 Catania, Italy

Department of Civil Engineering and Architecture, University of Catania, 95123 Catania, Italy

MIM, 98047 Saponara, Italy

References (42)

Show source-provided references
1. Murphy, W., Black, J., and Hastings, G. (2016). Handbook of Biomaterial Properties, Springer.10.1007/978-1-4939-3305-1 ↗
2. Merola, M., and Affatato, S. (2019). Materials for hip prostheses: A review of wear and loading considerations. Materials, 12.10.3390/ma12030495 ↗
3. Tamayo, J.A., Riascos, M., Vargas, C.A., and Baena, L.M. (2021). Additive manufacturing of Ti6Al4V alloy via electron beam melting for the development of implants for the biomedical industry. Heliyon, 7.10.1016/j.heliyon.2021.e06892 ↗
4. Production of customized hip stem prostheses—A comparison between conventional machining and electron beam melting (EBM)10.1108/RPJ-07-2011-0067 ↗
5. Wear characterizations of polyoxymethylene (POM) reinforced with carbon nanotubes (POM/CNTs) using the paraffin oil dispersion technique10.1007/s11837-015-1674-3 ↗
6. Optimization of cutting parameters while turning Ti-6Al-4 V using response surface methodology and machine learning technique10.1007/s12008-021-00774-0 ↗
7. Electron beam melting of titanium alloy and surface finish improvement through rotary ultrasonic machining10.1007/s00170-017-0365-3 ↗
8. Aliprandi, P., Giudice, F., Guglielmino, E., and Sili, A. (2019). Tensile and creep properties improvement of Ti-6Al-4V alloy specimens produced by Electron Beam Powder Bed Fusion Additive Manufacturing. Metals, 9.10.3390/met9111207 ↗
9. UHMWPE for biomedical applications: Performance and functionalization10.1016/j.eurpolymj.2020.109529 ↗
10. Advances in ultra high molecular weight polyethylene/hydroxyapatite composites for biomedical applications: A brief review10.1016/j.msec.2017.02.070 ↗
11. Catauro, M., Scolaro, C., Dal Poggetto, G., Pacifico, S., and Visco, A. (2020). wear resistant nanocomposites based on biomedical grade UHMWPE paraffin oil and carbon nano-filler: Preliminary biocompatibility and antibacterial activity investigation. Polymers, 12.10.3390/polym12040978 ↗
12. Visco, A., Grasso, A., Recca, G., Carbone, D.C., and Pistone, A. (2021). Mechanical, wear and thermal behavior of polyethylene blended with graphite treated in ball milling. Polymers, 13.10.3390/polym13060975 ↗
13. Potential of improving tribological performance of UHMWPE by engineering the Ti6Al4V counterfaces10.1016/S0043-1648(98)00356-1 ↗
14. Tribological behavior of UHMWPE (disc) against Ti6Al4V (pin) under different lubrication conditions10.1002/masy.202100294 ↗
15. Tribological behavior of biomedical grade UHMWPE with graphite-based fillers against EBM-Ti6Al4V pin under various lubricating conditions10.1002/app.52313 ↗
16. Rotational wear and friction of Ti-6Al-4V and CoCrMo against polyethylene and polycarbonate urethane10.1016/j.biotri.2021.100167 ↗
17. Tribological behavior of Ti6Al4 V alloy swing against UHMWPE under different lubrication10.1177/0892705719881180 ↗
18. Tribological behavior of UHMWPE reinforced with graphene oxide nanosheets10.1007/s11249-012-9919-6 ↗
19. Tribological behavior of UHMWPE against TiAl6V4 and CoCr28Mo alloys under dry and lubricated conditions10.1016/j.jmbbm.2016.07.002 ↗
20. Visco, A., Giudice, F., Guglielmino, E., Scolaro, C., and Sili, A. (2022). Experimental investigation of the tribological contact between Ti6Al4V-EBM pin and UHMWPE rotating sheet for prosthetic applications. Metals, 12.10.3390/met12091526 ↗
21. Wear coefficient equation for aluminium-based matrix composites against steel disc10.1016/S0043-1648(03)00191-1 ↗
22. Friction and wear of titanium alloys sliding against metal, polymer, and ceramic counterfaces10.1016/j.wear.2004.09.062 ↗
23. In vitro evaluation of artificial joints: A comprehensive review10.1007/s40436-018-00244-z ↗
24. A literature review of powder-based electron beam melting focusing on numerical simulations
25. A review of powdered additive manufacturing techniques for Ti-6al-4v biomedical applications10.1016/j.powtec.2018.03.010 ↗
26. Acquesta, A., and Monetta, T. (2020). As-built EBM and DMLS Ti-6Al-4V parts: Topography–corrosion resistance relationship in a simulated body fluid. Metals, 10.10.3390/met10081015 ↗
27. Effect of gamma irradiation on the ductile-to-brittle transition in ultra-high molecular weight polyethylene10.1016/S0141-3910(03)00212-X ↗
28. Thermal, Mechanical and rheological behaviors of nanocomposites based on UHMWPE/Paraffin oil/Carbon nanofiller obtained by using different dispersion techniques10.1007/s11837-016-1845-x ↗
29. Influence of vitamin C on morphological and thermal behaviour of biomedical UHMWPE10.1002/masy.201300202 ↗
30. Investigation of wear properties of EBM processed Ti6Al4V with UHMWPE for biomedical applications10.4028/www.scientific.net/AMM.811.14 ↗
31. N+ ion implantation of Ti6Al4V alloy and UHMWPE for total joint replacement application
32. A new material for hip prosthesis without considerable debris release10.1016/j.medengphy.2010.06.007 ↗
33. Taylor, J.R. (1997). An Introduction To Error Analysis. The Study of Uncertainties in Physical Measurements, University Science Books. [2nd ed.].
34. Properties of nanocomposites based on polyethylene (UHMWPE) and carbon nanotubes mixed by high-energy ball milling and UV-source irradiated10.1080/1023666X.2012.640493 ↗
35. Employment of carbon nanomaterials for welding polyethylene joints with a Nd:YAG laser10.1080/1023666X.2014.921108 ↗
36. Comparison of surface modifications induced by ion implantation in UHMWPE10.1080/10236660903518880 ↗
37. (2023, March 06). Extrulen 1020-Product Data Sheet. Available online: https://media.mcam.com/fileadmin/quadrant/documents/QEPP/EU/Product_Data_Sheets_PDF/Medical/MCAM-MEDI-403-A2-Extrulen-1020-EN-PDS-200506.pdf.
38. Tribological performance of bioimplants: A comprehensive review
39. Ageing of UHMWPE in presence of simulated synovial fluid10.1016/j.polymdegradstab.2021.109605 ↗
40. Sinha, S.K. (2018). Handbook of Polymer Tribology, World Scientific.10.1142/10647 ↗
41. A study of frictional wear behavior of Ti6Al4V and UHMWPE hybrid composite on TiN surface for bio-medical applications10.1016/j.triboint.2016.02.030 ↗
42. Salguero, J., Vazquez-Martinez, J., Sol, I., and Batista, M. (2018). Application of pin-on-disc techniques for the study of tribological interferences in the dry machining of A92024-T3 (Al–Cu) alloys. Materials, 11.10.3390/ma11071236 ↗