journal article·2023-01-22Open access

Module-Level Performance Evaluation for a Smart PV System Based on Field Conditions

Li Feng, Nowshad Amin, Jingwei Zhang, Kun Ding, Frank U. Hamelmann

Applied Sciences· Volume 13· Issue 3

Abstract

This study presents an approach with a simple structure, low complexity and low costs to evaluate the real-time status and localize the faults of a smart PV system at module level based on field conditions. The performance evaluation approach of a PV system is developed through the defined performance indicators, a complex data matrix to track module locations and a thermal model to determine the module temperature. The generalization potential of the proposed approach has been demonstrated through the successful experiment validation. The results show that the performance indicators are greatly corrected by the estimated module temperature with great linear agreement in R2 of 0.922 compared to actual measured temperature under same conditions. Due to the effective performance indicators capturing more performance differences caused by faults of cracks in 0.22 of PV_ΔV, partial shading in 0.47 of PV_ΔV, broken sensors in 0.17 of PI_ΔI and 1 of PV_ΔV separately, the proposed approach is very effective in evaluating the performance of PV modules at module level. Meanwhile, the faulty modules are diagnosed and located through these findings and the data matrix in the smart PV system. Additionally, the sensitivity of the proposed approach to fault in cracks is much higher than that of monitoring only the power.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Photovoltaic System Optimization Techniques · Solar Radiation and Photovoltaics · Solar Thermal and Photovoltaic Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Sustainable Energy (ISE), Universiti Tenaga Nasional (The National Energy University), Kajang 43000, Malaysia

College of Engineering (COE), Universiti Tenaga Nasional (The National Energy University), Kajang 43000, Malaysia

Solar Computing Lab, Bielefeld University of Applied Science, Artilleriestraße 9, 32427 Minden, Germany

College of Mechanical and Electrical Engineering, Hohai University, Changzhou 213022, China

Funding

Ministry of Higher Education of Malaysia (MoHE) · iRMC of Universiti Tenaga Nasional (@UNITEN, The National Energy University, Malaysia) · Bundesministerium für Bildung und Forschung, Germany

References (31)

Show source-provided references
1. Terrapass (2020, November 13). Advantages and Disadvantages of Using Renewable Energy. Available online: https://terrapass.com/blog/advantages-and-disadvantages-of-using-renewable-energy.
2. International Renewable Energy Agency (IRENA) (2022, April 12). Renewable Capacity Statistics 2022. Available online: https://www.irena.org/publications/2022/Apr/Renewable-Capacity-Statistics-2022.
3. Fraunhofer ISE-Energy Charts (2022, June 18). Annual Solar Share of Total Electricity Generation in Germany. Available online: https://www.energy-charts.info/charts/renewable_share/chart.htm?l=en&c=DE&interval=year&share=solar_share.
4. E3G, Pieter de Pous (2022, April 08). Germany’s Bold and Ambitious 100% Renewable Power Plan. Available online: https://www.e3g.org/news/germany-s-bold-and-ambitious-100-renewable-power-plan/.
5. Measurements, analyses and evaluation of residential PV systems by Japanese monitoring program10.1016/S0927-0248(02)00132-0 ↗
6. Köntges, M., Oreski, G., Herz, M., Jahn, U., Hacke, P., and Weiss, K.-A. (2017). Assessment of Photovoltaic Module Failures in the Field: International Energy Agency Photovoltaic Power Systems Programme: IEA PVPS Task 13, Subtask 3: Report IEA-PVPS T13-09: 2017, International Energy Agency.
7. (1998). Photovoltaic System Performance Monitoring Guidelines Formeasurement, Data Exchange and Analysis (Standard No. IEC 61724).
8. Aoun, N. (2020). Advanced Statistical Modeling, Forecasting, and Fault Detection in Renewable Energy Systems, IntechOpen Limited.
9. Romero-Fiances, I., Muñoz-Cerón, E., Espinoza-Paredes, R., Nofuentes, G., and Casa, J. (2019). Analysis of the Performance of Various PV Module Technologies in Peru. Energies, 12.10.3390/en12010186 ↗
10. Performance evaluation of the first Iranian large-scale photovoltaic power plant
11. Analysis of the performance of the photovoltaic power plant of Sourdun (France)10.1080/19397038.2021.1971321 ↗
12. Performance and Degradation Assessment of Large-scale Grid-connected Solar Photovoltaic Power Plant in Tropical Semi-arid Environment of India10.1016/j.solener.2020.04.011 ↗
13. Performance Analysis of 954,809 kWp PV Array of Sheikh Zayed Solar Power Plant (Nouakchott, Mauritania)10.1016/j.ref.2019.11.002 ↗
14. Impact of Tropical Desert Maritime Climate on the Performance of a PV Grid-connected Power Plant10.1016/j.renene.2018.03.013 ↗
15. Paredes-Parra, J., Mateo-Aroca, A., Silvente-Niñirola, G., Bueso, M.C., and Molina-García, Á. (2018). PV Module Monitoring System Based on Low-Cost Solutions: Wireless Raspberry Application and Assessment. Energies, 11.10.3390/en11113051 ↗
16. A Comparative Performance Analysis of A 1 MW CIS PV System and A 5 kW Crystalline-Si PV System under the Tropical Climate of Indonesia10.14716/ijtech.v10i6.3612 ↗
17. An Overview on Performance of PV Plants Commissioned at Different Places in the World10.1016/j.esd.2019.10.004 ↗
18. Guerriero, P., Vallone, G., d’Alessandro, V., and Daliento, S. (2013, January 11–13). Innovative algorithm for true maximum detection based on individual PV panel sensor network. Proceedings of the 2013 International Conference on Clean Electrical Power (ICCEP), Alghero, Italy.10.1109/ICCEP.2013.6586963 ↗
19. Sentinella: Smart monitoring of photovoltaic systems at panel level10.1109/TIM.2014.2386931 ↗
20. Online two section PV array fault diagnosis with optimized voltage sensor locations10.1109/TIE.2015.2448066 ↗
21. AEG Industrial Solar (2022, December 21). Available online: https://www.aeg-industrialsolar.de.
22. KOSTAL Solar Electric (2022, December 21). Available online: https://www.kostal-solar-electric.com/en-gb/.
23. Kipp & Zonen, B.V (2022, December 21). RT1 Smart Rooftop Monitoring System. Available online: https://www.kippzonen.com/Product/420/RT1-Smart-Rooftop-Monitoring-System#.YtaJjOrP2Uk.
24. (2009). Photovoltaic Devices–Procedures for Temperature and Irradiance Corrections to Measured I–V Characteristics (Standard No. IEC 60891-1).
25. Rheinland, T.U., Herrmann, W., and Wiesner, W. (1996, January 16–19). Current-Voltage translation Procedure for PV Generators in the German 1000 Roofs Programme. Proceedings of the EUROSUN Conference, Freiburg, Germany.
26. Degradation analysis of photovoltaic modules after operating for 22 years. A case study with comparisons10.1016/j.solener.2021.04.026 ↗
27. Adrian, B. (2013). Convective Heat Transfer, Wiley. [4th ed.].
28. Feng, L., Hempelmann, S., Basoglu, C., and Hamelmann, F. (2019, January 4–8). A Novel Temperature Model for Determination PV Module Temperature. Proceedings of the 29th International PV Science and Engineering Conference (PVSEC-29), Xi’an, China.
29. Hammami, M., Torretti, S., Grimaccia, F., and Grandi, G. (2017). Thermal and Performance Analysis of a Photovoltaic Module with an Integrated Energy Storage System. Appl. Sci., 7.10.3390/app7111107 ↗
30. Guyer, E. (1999). Handbook of Applied Thermal Design, CRC Press.
31. Improving the accuracy of temperature coefficient measurement of a PV module by accounting for the transient temperature difference between cell and backsheet10.1016/j.solener.2022.03.049 ↗