journal article·2022-09-18Open access

Potential of Fluid Dynamic Bowtie Filter for Dose Reduction and Image Quality Improvement of Cone-Beam CT

Xin Lin, Weihai Zhuo, Haikuan Liu, Tianwu Xie

Applied Sciences· Volume 12· Issue 18

Abstract

Reducing radiation dose to patients without compromising imaging quality has been an important issue in the medical use of X-ray computed tomography (CT). In this study, based on the conceptual designs of different types of attenuation filters, the radiation doses to patients who undergo a typical head, thorax and abdomen scan using a cone-beam CT with different scanning protocols were simulated using the Monte Carlo method, and the isotropy of the noise power spectrum (NPS) of the reconstructed images was also calculated. Compared to the scanning protocol without attenuation and tube current modulation (TCM), the results showed that the fluid dynamic bowtie filter (FDB) combined with the TCM technique reduced the average organ dose by 70%, 34% and 60% for a typical head, thorax and abdomen scan, respectively, and the NPS isotropy of the reconstructed images was also significantly improved. Compared to most currently used static bowtie filters, the FDB has a higher potential to reduce the dose for patients undergoing CT scans. Further efforts are warranted to make the FDB technique clinically useful.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiation Dose and Imaging · Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Radiation Medicine, Fudan University, 2094 Xietu Road, Shanghai 200032, China

Funding

National Natural Science Foundation of China

References (43)

Show source-provided references
1. United Nations Scientific Committee on the Effects of Atomic Radiation (2022). Sources, Effects and Risks of Ionizing Radiation UNSCEAR 2020/2021 Report, United Nations Scientific Committee on the Effects of Atomic Radiation.
2. Estimated risks of radiation-induced fatal cancer from pediatric CT10.2214/ajr.176.2.1760289 ↗
3. Estimating cancer risks from pediatric CT: Going from the qualitative to the quantitative10.1007/s00247-002-0671-1 ↗
4. Recurrent CT, Cumulative Radiation Exposure, and Associated Radiation-induced Cancer Risks from CT of Adults10.1148/radiol.2511081296 ↗
5. Strategies for reducing radiation dose in CT10.1016/j.rcl.2008.10.006 ↗
6. Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies10.1118/1.598779 ↗
7. Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements10.1118/1.598738 ↗
8. Dose reduction in CT by on-line tube current control: Principles and validation on phantoms and cadavers10.1007/s003300050674 ↗
9. An anatomically adapted variation of the tube current in CT. Studies on radiation dosage reduction and image quality10.1055/s-2007-1016013 ↗
10. Dose reduction in helical CT: Dynamically adjustable z-axis X-ray beam collimation10.2214/AJR.09.2878 ↗
11. The effects of compensator and imaging geometry on the distribution of X-ray scatter in CBCT10.1118/1.3539575 ↗
12. Compensators for dose and scatter management in cone-beam computed tomography10.1118/1.2740466 ↗
13. The influence of bowtie filtration on cone-beam CT image quality10.1118/1.3017470 ↗
14. Adaptive streak artifact reduction in computed tomography resulting from excessive X-ray photon noise10.1118/1.598410 ↗
15. Stiller, W., Veloza, S., and Kauczor, H. (November, January 27). Attenuation-based dynamic CT beam-shaping filtration in dependence of fan and projection angle: Evaluation of a new method for radiation exposure reduction by Monte-Carlo simulation of spatial dose distribution. Proceedings of the 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), Anaheim, CA, USA.10.1109/NSSMIC.2012.6551599 ↗
16. The feasibility of a piecewise-linear dynamic bowtie filter10.1118/1.4789630 ↗
17. A prototype piecewise-linear dynamic attenuator10.1088/0031-9155/61/13/4974 ↗
18. Realization of fluence field modulated CT on a clinical TomoTherapy megavoltage CT system10.1088/0031-9155/60/18/7245 ↗
19. Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results10.1118/1.4773880 ↗
20. Design of a digital beam attenuation system for computed tomography: Part I. System design and simulation framework10.1118/1.4773879 ↗
21. Experimental realization of fluence field modulated CT using digital beam attenuation10.1088/0031-9155/59/5/1305 ↗
22. Technical Note: Sheet-based dynamic beam attenuator—A novel concept for dynamic fluence field modulation in X-ray CT10.1002/mp.13690 ↗
23. The z-sbDBA, a new concept for a dynamic sheet-based fluence field modulator in X-ray CT10.1002/mp.14430 ↗
24. On the potential of ROI imaging in X-ray CT—A comparison of novel dynamic beam attenuators with current technology10.1002/mp.14879 ↗
25. Dynamic bowtie for fan-beam CT
26. Two-dimensional dynamic fluid bowtie attenuators10.1117/1.JMI.3.1.013502 ↗
27. Liu, F., Yang, Q., Cong, W., and Wang, G. (2014). Dynamic bowtie filter for cone-beam/multi-slice CT. PLoS ONE, 9.10.1371/journal.pone.0103054 ↗
28. Fluid-filled dynamic bowtie filter: Description and comparison with other modulators10.1002/mp.13272 ↗
29. Compensator models for fluence field modulated computed tomography10.1118/1.4829513 ↗
30. Fluence field optimization for noise and dose objectives in CT10.1118/1.3574885 ↗
31. Technical Note: Spektr 3.0—A computational tool for X-ray spectrum modeling and analysis10.1118/1.4955438 ↗
32. Physical basis of analytical atomic absorption spectrometry—Pertinence of beer-lambert law10.1021/ac60201a006 ↗
33. A Fast Algorithm to Calculate the Exact Radiological Path through a Pixel Or Voxel Space
34. The cone-beam algorithm of Feldkamp, Davis, and Kress preserves oblique line integrals10.1118/1.1759828 ↗
35. Control algorithms for dynamic attenuators10.1118/1.4875727 ↗
36. A framework to simulate CT images with tube current modulation
37. Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation10.1118/1.4883816 ↗
38. GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications10.1088/0031-9155/60/13/4987 ↗
39. Hubbell, J.H. (2022, March 15). Tables of X-ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients (Version 1.4), Available online: http://physics.nist.gov/xaamdi.
40. Measurement of organ dose in chest CT examination using Monte Carlo simulation
41. Dose reduction in CT using bismuth shielding: Measurements and Monte Carlo simulations10.1093/rpd/ncp278 ↗
42. Monte Carlo Simulation and Dose Calculation of Chest CT Scan with Tube Current Modulation10.1118/1.4815470 ↗
43. Monte Carlo CT Dose Calculation: A Comparison Between Experiment and Simulation Using ARCHER-CT10.1118/1.4889155 ↗