journal article·2021-06-10Open access

Simulation and Experimental Study of the Near Field Probe in the Form of a Folded Dipole for Measuring Glucose Concentration

Aleksandr Gorst, Kseniya Zavyalova, Aleksandr Mironchev, Andrey Zapasnoy, Andrey Klokov

Applied Sciences· Volume 11· Issue 12

Abstract

The article investigates the near-field probe of a special design to account for changes in glucose concentration. The probe is designed in such a way that it emits radiation in both directions from its plane. In this paper, it was proposed to modernize this design and consider the unidirectional emission of the probe in order to maximize the signal and reduce energy loss. We have done extensive research for both bidirectional and unidirectional probe designs. Numerical simulations and field experiments were carried out to determine different concentrations of glucose (0, 4, 5.3, 7.5 mmol/L). Numerical modeling of a unidirectional probe showed that the interaction of radiation generated by such a probe with a multilayer structure simulating a human hand showed a better result and high sensitivity compared to a bidirectional probe. Further, based on the simulation results, a phantom (physical model) of a human hand was recreated from layers with dielectric properties as close as possible to the properties of materials during simulation. The probe was constructed from a copper tube and matched both the geometric and physical parameters of the model. The experimental measurement was carried out using a vector network analyzer in the frequency range 2–10 GHz. The experimental measurement was carried out using a vector network analyzer in the frequency range 2–10 GHz for the unidirectional and bidirectional probes. Further, the results of the experiment were compared with the results of numerical simulation. According to the results of multiple experiments, it was found that the average deviation between the concentrations was 2 dB for a unidirectional probe and 0.4 dB for a bidirectional probe. Thus, the sensitivity of the unidirectional probe was 1.5 dB/(mmol/L) for the bidirectional one 0.3 dB/(mmol/L). Thus, the improved design of the near-field probe can be used to record glucose concentrations.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Microwave and Dielectric Measurement Techniques · Microwave Imaging and Scattering Analysis · Wireless Body Area Networks

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Radiophysics Faculty, Tomsk State University, 634050 Tomsk, Russia

Funding

Russian Science Foundation

References (29)

Show source-provided references
1. Villena Gonzales, W., Mobashsher, A.T., and Abbosh, A. (2019). The progress of glucose monitoring—A review of invasive to minimally and non-invasive techniques, devices and sensors. Sensors, 19.10.3390/s19040800 ↗
2. Yilmaz, T., Foster, R., and Hao, Y. (2019). Radio-frequency and microwave techniques for non-invasive measurement of blood glucose levels. Diagnostics, 9.10.3390/diagnostics9010006 ↗
3. Schoemaker, M., Schmelzeisen-Redeker, G., and Jager, J. (2014, January 5–8). CGM sensor design principles for reliable and accurate glucose monitoring in the subcutaneous tissue. Proceedings of the 7th International Conference on Advanced Technologies & Treatments for Diabetes, Vienna, Austria.
4. Electrode systems for continuous monitoring in cardiovascular surgery10.1111/j.1749-6632.1962.tb13623.x ↗
5. Re-usable electrochemical glucose sensors integrated into a smartphone platform10.1016/j.bios.2017.10.019 ↗
6. Optical methods for noninvasive blood glucose monitoring10.1007/s10527-012-9249-x ↗
7. Design, development, and evaluation of a novel microneedle array-based continuous glucose monitor10.1177/1932296814526191 ↗
8. Handheld optical coherence tomography scanner for primary care diagnostics10.1109/TBME.2010.2096816 ↗
9. A noninvasive measurement of blood glucose concentration by UWB microwave spectrum10.1109/LAWP.2016.2618946 ↗
10. Broadband wireless sensing system for non-invasive testing of biological samples10.1109/JETCAS.2018.2829205 ↗
11. Coplanar waveguide transmission line loaded with electric-LC resonator for determination of glucose concentration sensing10.1109/JSEN.2017.2652121 ↗
12. Design and in vitro interference test of microwave noninvasive blood glucose monitoring sensor10.1109/TMTT.2015.2472019 ↗
13. Simulating the effects of skin thickness and fingerprints to highlight problems with non-invasive RF blood glucose sensing from fingertips10.1109/JSEN.2017.2757083 ↗
14. Simulation of a non-invasive glucometer based on a microwave resonator sensor10.1088/1742-6596/477/1/012020 ↗
15. Ultrahigh-sensitivity mediator-free biosensor based on a microfabricated microwave resonator for the detection of micromolar glucose concentrations10.1109/TMTT.2015.2503275 ↗
16. Guariti, G., Hofmann, M., Weigel, R., Fischer, G., and Kissinger, D. (2013, January 2–7). Determination of sugar concentration in aqueous solutions using ultra-wideband microwave impedance spectroscopy. Proceedings of the 2013 IEEE MTT-S International Microwave Symposium Digest (MTT), Seattle, WA, USA.10.1109/MWSYM.2013.6697563 ↗
17. Lin, Y.R., Hung, C.C., Chiu, H.Y., Chang, P.H., Li, B.R., Cheng, S.J., Yang, J.W., Lin, S.F., and Chen, G.Y. (2018). Noninvasive glucose monitoring with a contact lens and smartphone. Sensors, 18.10.3390/s18103208 ↗
18. Gorst, A., Zavyalova, K., Yakubov, V., Mironchev, A., and Zapasnoy, A. (2020). Theoretical Simulation of the Near-Field Probe for Non-Invasive Measurements on Planar Layers with Biological Characteristics. Bioengineering, 7.10.3390/bioengineering7040149 ↗
19. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues10.1088/0031-9155/41/11/003 ↗
20. Freer, B., and Venkataraman, J. (2010, January 11–17). Feasibility study for non-invasive blood glucose monitoring. Proceedings of the 2010 IEEE Antennas and Propagation Society International Symposium, Toronto, ON, Canadan.10.1109/APS.2010.5561003 ↗
21. Tissue-mimicking materials for breast phantoms up to 50 GHz10.1088/1361-6560/aafeec ↗
22. Tissue-mimicking phantom materials for narrowband and ultrawideband microwave applications10.1088/0031-9155/50/18/001 ↗
23. Di Meo, S., Matrone, G., and Pasian, M. (2021). Experimental Validation on Tissue-Mimicking Phantoms of Millimeter-Wave Imaging for Breast Cancer Detection. Appl. Sci., 11.10.3390/app11010432 ↗
24. Microwave breast imaging: Clinical advances and remaining challenges10.1109/TBME.2018.2809541 ↗
25. Gorst, A., Zavyalova, K., Shipilov, S., Yakubov, V., and Mironchev, A. (2020). Microwave Method for Measuring Electrical Properties of the Materials. Appl. Sci., 10.10.3390/app10248936 ↗
26. Microstrip line-based glucose sensor for noninvasive continuous monitoring using the main field for sensing and multivariable crosschecking10.1109/JSEN.2018.2877691 ↗
27. Noncontact characterization of glucose by a waveguide microwave probe10.1016/j.cap.2008.08.007 ↗
28. Millimeter-wave adaptive glucose concentration estimation with complex-valued neural networks10.1109/TBME.2018.2883085 ↗
29. WGM-based sensing of characterized glucose-aqueous solutions at mm-waves10.1109/ACCESS.2020.2975805 ↗