journal article·2020-05-28Open access

Effective Suppression of Residual Magnetic Interference in a Conductive Shielded Room for Ultra-Low Field Nuclear Magnetic Resonance

Yiqiu Tan, Danfeng Zhou, Mengxiao Song, Jie Li

Applied Sciences· Volume 10· Issue 11

Abstract

Residual magnetic interference induced by applied magnetic field pulses inside a conductive shielded room (SR) has been a common issue in ultra-low-field (ULF) nuclear magnetic resonance (NMR). The rapid cutoff of the applied pre-polarizing field (Bp) induces eddy currents in the walls of the SR, which produces a decaying residual magnetic interference that may cause severe image distortions and signal loss. In this study, a pair of cancellation coils (CC) and control electronics were designed for the suppression of the residual magnetic interference in a SR. Simulations show that this method was effective in suppressing the residual magnetic field (Br) after removal of the pre-polarizing magnetic field. Then, a small-scale SR was designed and the effectiveness of this cancellation scheme was experimentally verified. The test results showed a good agreement with the simulation, which indicated that the cancellation scheme was capable of reducing Br field to a much lower level. The scheme proposed in this study provides a solution for suppressing the residual magnetic field in the ULF NMR system. After decoupling the eddy–current field, the effect of the suppression may be further improved by optimization of the cancellation coil in further work.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced MRI Techniques and Applications · Atomic and Subatomic Physics Research · NMR spectroscopy and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Intelligence Science and Technology, National University of Defense Technology, Changsha 410073, China

State Key Laboratory of Functional Materials for Informatic, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai 200050, China

Funding

Opening Foundation of the State Key Laboratory of Functional Materials for Informatics · National Key R&D Program of China

References (20)

Show source-provided references
1. Application of Ultra-Low Field SQUID-NMR/NMR System to Contaminant Detection
2. Development of Ultra-low Field SQUID-NMR System with an LC Resonator10.1016/j.phpro.2015.05.114 ↗
3. Unshielded SQUID Sensors for Ultra-Low-Field Magnetic Resonance Imaging10.1109/TASC.2018.2791022 ↗
4. Magnetic Nanoparticles in the Imaging of Tumor Angiogenesis10.3390/app2020525 ↗
5. SQUID-Detected Magnetic Resonance Imaging in Microtesla Fields10.1146/annurev.bioeng.9.060906.152010 ↗
6. Conductive shield for ultra-low-field magnetic resonance imaging: Theory and measurements of eddy currents10.1063/1.4867220 ↗
7. Ultra-low field magnetic resonance imaging detection with gradient tensor compensation in urban unshielded environment10.1063/1.4795516 ↗
8. A compact SQUID-detected magnetic resonance imaging system under microtesla field in a magnetically unshielded environment10.1063/1.3656984 ↗
9. Pre-polarization enhancement by dynamic nuclear polarization in SQUID-based ultra-low-field nuclear magnetic resonance10.1088/0953-2048/23/11/115008 ↗
10. Co-registration of interleaved MEG and ULF NMR using a 7 channel low-T c SQUID system10.1109/TASC.2010.2088353 ↗
11. Numerical Modeling and Material Characterization for Multilayer Magnetically Shielded Room Design10.1109/TMAG.2017.2771314 ↗
12. Performance study of aluminum shielded room for ultra-low-field magnetic resonance imaging based on SQUID: Simulations and experiments
13. Simulation and Measurements of Transient Fields from Conductive Plates of Shielded Room for SQUID-Based Ultralow Field Magnetic Resonance Imaging
14. SQUID Gradiometer Module for Fetal Magnetocardiography Measurements inside a Thin Magnetically Shielded Room
15. Avoiding eddy-current problems in ultra-low-field NMR with self-shielded polarizing coils
16. Effective cancellation of residual magnetic interference induced from a shielded environment for precision magnetic measurements10.1063/1.3643427 ↗
17. Dynamical cancellation of pulse-induced transients in a metallic shielded room for ultra-low-field magnetic resonance imaging10.1063/1.4906058 ↗
18. Improvement of the properties of an eddy-current magnetic shield with active compensation10.1088/0022-3735/20/2/007 ↗
19. Reduction of Eddy Current Loss in Rectangular Coil Using Magnetic Shield: Analysis with Homogenization Method
20. Evaluation of cancellation coil for precision magnetic measurements with strong prepolarization field inside shielded environment