Study on Air-Cooled Structure of Direct-Drive Outer-Rotor Permanent Magnet Synchronous Generator for Wind Power Generation
Source abstract
Abstract
Direct-drive permanent magnet synchronous generators (DD-PMSGs) have been widely adopted in wind power generation systems owing to their distinctive advantages, including direct-drive operation, high power density, and superior energy conversion efficiency. However, the high power density of the generator inevitably leads to heat generation issues, which affect the reliability of the generator. To address the thermal issues in the 4.5 MW direct-drive permanent magnet synchronous generator (DD-PMSG), this paper proposes a novel forced air-cooling ventilation system. Through comprehensive computational fluid dynamics (CFD) simulations and fundamental thermodynamic analysis, the cooling performance is systematically evaluated to determine the optimal width of the stator ventilation ducts. Furthermore, based on the temperature distribution of the stator and rotor, three optimization schemes for non-uniform core segments are proposed. By comparing the ventilation cooling performance under three structural schemes, the optimal structural scheme is provided for the generator. Finally, the feasibility of the heat dissipation scheme and the accuracy of the simulation calculations are verified by fabricating a prototype and setting up an experimental platform. The above conclusions and research results can provide some reference for the design of the core ventilation ducts structure of subsequent wind turbines.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electric Motor Design and Analysis · Wind Energy Research and Development · Magnetic Bearings and Levitation Dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
Wolong Electric Nanyang Explosion Protection Group Co., Ltd., Nanyang 473008, China
School of Control and Mechanical Engineering, Tianjin Chengjian University, Tianjin 300384, China
School of Engineering and Technology, Tianjin Agricultural University, Tianjin 300384, China
Funding
Henan Province Key Science and Technology Program of China
References (21)
Show source-provided references
1. How do solar photovoltaic and wind power promote the joint poverty alleviation and clean energy development: An evolutionary game theoretic study10.1016/j.renene.2023.119296 ↗
2. Empirical evidence based effectiveness assessment of policy regimes for wind power development in China10.1016/j.rser.2022.112535 ↗
3. Nomandela, S., Mnguni, M.E.S., and Raji, A.K. (2025). A Case Study on the Validation of Renewable Energy Grid Code Compliance for a Large-Scale Wind Power Plant Grid-Connected Mode of Operation in Real-Time Simulation. Appl. Sci., 15.10.3390/app15105521 ↗
4. Wind turbine generator failure analysis and fault diagnosis: A review10.1049/rpg2.13104 ↗
5. Singh, G., Matuonto, M., and Sundaram, K. (2019, January 26–28). Impact of imbalanced wind turbine generator cooling on reliability. Proceedings of the 2019 10th International Renewable Energy Congress (IREC), Sousse, Tunisia.10.1109/IREC.2019.8754545 ↗
6. Cen, Y., Shen, H., Wang, X., Wu, Y., and Du, J. (2024). Multi-Objective Optimization Analysis of Electromagnetic Performance of Permanent Magnet Synchronous Motors Based on the PSO Algorithm. Energies, 17.10.3390/en17184637 ↗
7. Direct liquid cooling for an outer-rotor direct-drive permanent-magnet synchronous generator for wind farm applications10.1049/iet-epa.2014.0342 ↗
8. Investigation of winding cooling enhancement and thermal modelling of large-power high-torque-density direct-drive PMSM10.1049/elp2.12351 ↗
9. Study on the suppression effect of variable hydrogen parameters on the temperature rise of the turbo-generator rotor under deep peak regulation10.1049/elp2.12360 ↗
10. Design and research of cooling system for 2.5 MW permanent magnet wind turbine10.1016/j.renene.2020.10.023 ↗
11. Universal cooling of data centres: A cfd analysis10.1016/j.egypro.2017.12.215 ↗
12. CFD simulation and optimisation of a low energy ventilation and cooling system10.3390/computation3020128 ↗
13. Liu, W., Chen, J., Zhang, C., Cui, Z.-Q., and Wang, X. (2017, January 19–21). Ventilation system design and rotor air friction loss of high-speed permanent magnet machines. Proceedings of the 2017 IEEE International Conference on Cybernetics and Intelligent Systems (CIS) and IEEE Conference on Robotics, Automation and Mechatronics (RAM), Ningbo, China.10.1109/ICCIS.2017.8274793 ↗
14. Influence of rotor radial ventilation ducts number on temperature distribution of rotor excitation winding and fluid flow state between two poles of a fully air-cooled hydro-generator10.1109/TIE.2017.2650871 ↗
15. Ventilation cooling design for a novel 350-MW air-cooled turbo generator10.1109/ACCESS.2018.2875757 ↗
16. 3D temperature field of high-temperature gas cooled reactor cooling medium drive motor and ventilation structure improvement10.1049/iet-epa.2017.0661 ↗
17. Gas friction loss in stator ventilation ducts of the drive motor for the cooling medium in a high-temperature gas-cooled reactor10.1109/TIE.2018.2829670 ↗
18. Effect of helium on temperature rise of helium blower drive motor in high-temperature gas-cooled reactor10.1016/j.applthermaleng.2019.113888 ↗
19. Ventilation and thermal improvement of radial forced air-cooled FSCW permanent magnet synchronous wind generators10.1109/TIA.2017.2686350 ↗
20. CFD-based design and analysis of the ventilation of an electric generator model, validated with experiments10.5293/IJFMS.2015.8.2.113 ↗
21. Design and optimisation of oil injection pipe cooling structure for permanent magnet synchronous motors in hybrid electric vehicles10.1049/elp2.12393 ↗