journal article·2025-05-22Open access

Agreement Between a Wristwatch and a Free Optical Sensor with a Chest Strap in Measuring HR Variations During Front Crawl Swimming

Raul F. Bartolomeu, Vasco Silva, Ana Pereira, Gonçalo Morais, Kamil Sokołowski, Marek Strzała, Jorge E. Morais, José E. Teixeira

Applied Sciences· Volume 15· Issue 11

Abstract

Wearables with optical sensors for heart rate (HR) measurement are widely available in the market. However, their accuracy in water is still underexplored. The aim of the present study was to test the agreement of two different devices for HR monitoring with a chest strap while swimming at different intensities. Twenty male and ten female subjects (mean 19.6 ± 0.7 years old, 173.3 ± 5.4 cm, and 67.1 ± 6.6 kg) performed an intermittent progressive protocol of 3 × 30 s tethered front crawl swimming followed by a 1 min rest period. A chest strap, a wristwatch, and a multi-site optical sensor placed at the temple were used simultaneously. A strong association, an excellent intra-class correlation, and a low mean bias were denoted (R2 = 0.85, ICC = 0.94, b = −1) between HRchest vs. HRtemple. Both indicators increased throughout the test, denoting an increase in accuracy from light to vigorous exercise intensity. HRchest and HRwatch showed a moderate association for the whole test (R2 = 0.23) but a weak association, a poor consistency, and a high mean bias stepwise (0.01 ≤ R2 ≤ 0.06, 0.03 ≤ ICC ≤ 0.42, −48.1 ≤ b≤ −16.1). During swimming, the HR values from the temple showed a better agreement with the chest strap than those from the wristwatch. The temple reading accuracy might be enhanced by using the device during the dryland warm-up routine.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Sports Performance and Training · Non-Invasive Vital Sign Monitoring

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Sports and Expressions, Polytechnic of Guarda, 6300-559 Guarda, Portugal

Department of Sport Sciences, Instituto Politécnico de Bragança, 5300-253 Bragança, Portugal

Sport Physical Activity and Health & Innovation Center (SPRINT), 2040-413 Rio Maior, Portugal

Research Centre for Active Living and Wellbeing (LiveWell), Polytechnic of Bragança, 5300-253 Bragança, Portugal

Department of Water Sports, Institute of Sports Sciences, University of Physical Culture, 31-571 Cracow, Poland

Department of Sports Sciences, Polytechnic of Cávado and Ave, 4806-909 Guimarães, Portugal

References (42)

Show source-provided references
1. Is Speed Reserve Related to Critical Speed and Anaerobic Distance Capacity in Swimming?10.1519/JSC.0000000000000403 ↗
2. Swimming Training Load Control: An Integrated Approach
3. Biancardi, C.M., Lagos-Hausheer, L., Pequera, G., Castroman, E., Cazot, F., Martinez, E., and Bona, R.L. (2023, January 16–17). Energetic Cost of Running in Track and Treadmill. Proceedings of the International Conference on Sport Sciences Research and Technology Support, icSPORTS-Proceedings, Rome, Italy.10.5220/0012202300003587 ↗
4. Martnes, J.J., and Bere, E. (2023). Physical Activity When Riding an Electric-Assisted Bicycle with and without Cargo. Front. Sports Act. Living, 5.10.3389/fspor.2023.1179043 ↗
5. Morais, J.E., and Bragada, J.A. (2022). Relationship between Oxygen Uptake Reserve and Heart Rate Reserve in Young Male Tennis Players: Implications for Physical Fitness Monitoring. Int. J. Environ. Res. Public Health, 19.10.3390/ijerph192315780 ↗
6. Björklund, G., Swarén, M., Norman, M., Alonso, J., and Johansson, F. (2020). Metabolic Demands, Center of Mass Movement and Fractional Utilization of V O2max in Elite Adolescent Tennis Players During On-Court Drills. Front. Sports Act. Living, 2.10.3389/fspor.2020.00092 ↗
7. Resultant Equations for Training Load Monitoring during a Standard Microcycle in Sub-Elite Youth Football: A Principal Components Approach10.7717/peerj.15806 ↗
8. Accuracy of Heart Rate Measured by Military-Grade Wearable ECG Monitor Compared with Reference and Commercial Monitors10.1136/military-2023-002541 ↗
9. Schaffarczyk, M., Rogers, B., Reer, R., and Gronwald, T. (2022). Validity of the Polar H10 Sensor for Heart Rate Variability Analysis during Resting State and Incremental Exercise in Recreational Men and Women. Sensors, 22.10.3390/s22176536 ↗
10. RR Interval Signal Quality of a Heart Rate Monitor and an ECG Holter at Rest and during Exercise10.1007/s00421-019-04142-5 ↗
11. Hettiarachchi, I.T., Hanoun, S., Nahavandi, D., and Nahavandi, S. (2019). Validation of Polar OH1 Optical Heart Rate Sensor for Moderate and High Intensity Physical Activities. PLoS ONE, 14.10.1371/journal.pone.0217288 ↗
12. Martín-Escudero, P., Cabanas, A.M., Dotor-Castilla, M.L., Galindo-Canales, M., Miguel-Tobal, F., Fernández-Pérez, C., Fuentes-Ferrer, M., and Giannetti, R. (2023). Are Activity Wrist-Worn Devices Accurate for Determining Heart Rate during Intense Exercise?. Bioengineering, 10.10.3390/bioengineering10020254 ↗
13. Olstad, B.H., and Zinner, C. (2020). Validation of the Polar OH1 and M600 Optical Heart Rate Sensors during Front Crawl Swim Training. PLoS ONE, 15.10.1371/journal.pone.0231522 ↗
14. Evaluation of Pulse Rate Measurement with a Wrist Worn Device during Different Tasks and Physical Activity
15. Validity of the Polar Verity Sense during Swimming at Different Locations and Intensities10.1111/sms.14494 ↗
16. Heart Rate Equivalency of the Fitbit Charge HR During Continuous Aerobic Exercise10.1123/jmpb.2018-0009 ↗
17. Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking
18. Validity of the Smarthealth Watch to Measure Heart Rate during Rest and Exercise10.1080/1091367X.2011.539089 ↗
19. Thomas, J., Doyle, P., and Doyle, J.A. (2022). Validity of Optical Heart Rate Measurement in Commercially Available Wearable Fitness Tracking Devices. bioRxiv, 9.10.1101/2022.09.29.510075 ↗
20. Commercial Smart Watches and Heart Rate Monitors: A Concurrent Validity Analysis10.1519/JSC.0000000000004482 ↗
21. Validation of a Photoplethysmographic Heart Rate Monitor: Polar OH110.1055/a-0875-4033 ↗
22. Heart Rate Monitors: State of the Art10.1080/026404198366920 ↗
23. Polar Research and Technology (2019). Polar H10 Heart Rate Sensor System [White Paper], Polar Research and Technology.
24. Polar Research and Technology (2017). Polar Optical Heart Rate [White Paper], Polar Research and Technology.
25. Polar Electro (2021). Polar OH1 [Owners Manual], Polar Electro.
26. Bragada, J.A., Bartolomeu, R.F., Rodrigues, P.M., Magalhães, P.M., Bragada, J.P., and Morais, J.E. (2022). Validation of StepTest4all for Assessing Cardiovascular Capacity in Young Adults. Int. J. Environ. Res. Public Health, 19.10.3390/ijerph191811274 ↗
27. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research10.1016/j.jcm.2016.02.012 ↗
28. Statistical Methods for Assessing Agreement between Two Methods of Clinical Measurement10.1016/j.ijnurstu.2009.10.001 ↗
29. Agreement between Different Methods to Measure the Active Drag Coefficient in Front-Crawl Swimming10.5114/jhk/159605 ↗
30. Validity of Seven Commercially Available Heart Rate Monitors10.1207/S15327841MPEE0604_3 ↗
31. How Well Does the Polar Vantage XL Heart Rate Monitor Estimate Actual Heart Rate
32. Accuracy of Commercially Available Heart Rate Monitors in Athletes: A Prospective Study10.21037/cdt.2019.06.05 ↗
33. Polar Electro (2025, February 28). What are the Pros and Cons of Different Methods for Measuring Heart Rate?. Available online: https://support.polar.com/us-en/what_are_the_pros_and_cons_of_wrist_based_heart_rate_measurement_and_measuring_heart_rate_with_a.
34. Relationship between Measurement Site and Motion Artifacts in Wearable Reflected Photoplethysmography10.1007/s10916-010-9505-0 ↗
35. Budig, M., Keiner, M., Stoohs, R., Hoffmeister, M., and Höltke, V. (2021). Heart Rate and Distance Measurement of Two Multisport Activity Trackers and a Cellphone App in Different Sports: A Cross-Sectional Validation and Comparison Field Study. Sensors, 22.10.3390/s22010180 ↗
36. Cosoli, G., Antognoli, L., Veroli, V., and Scalise, L. (2022). Accuracy and Precision OfWearable Devices for Real-Time Monitoring of Swimming Athletes. Sensors, 22.10.3390/s22134726 ↗
37. Shcherbina, A., Mikael Mattsson, C., Waggott, D., Salisbury, H., Christle, J.W., Hastie, T., Wheeler, M.T., and Ashley, E.A. (2017). Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort. J. Pers. Med., 7.10.3390/jpm7020003 ↗
38. Hung, S.H., Serwa, K., Rosenthal, G., and Eng, J.J. (2025). Validity of Heart Rate Measurements in Wrist-Based Monitors across Skin Tones during Exercise. PLoS ONE, 20.10.1371/journal.pone.0318724 ↗
39. Maglischo, E. (2003). Swimming Fastest, Human Kinetics.
40. The Polar® OH1 Optical Heart Rate Sensor Is Valid during Moderate-Vigorous Exercise10.1055/a-0631-0920 ↗
41. Feasibility of Using an Armband Optical Heart Rate Sensor in Naturalistic Environment
42. Understanding Bland Altman Analysis10.11613/BM.2015.015 ↗