journal article·2024-08-13Open access

Experimental and Parametric Analysis of Pull-Out Resistance of Notched T-Perfobond Connectors

Zifa Dong, Shuangjie Zheng, Lizhe Jiao, Xiaoqing Xu, Yao Yao, Zhuoru Gao, Haifeng Li

Applied Sciences· Volume 14· Issue 16

Abstract

To enhance the uplift capacity and facilitate the installation of multi-row perfobond connectors at shallow burial depths, this study puts forward a novel notched T-perfobond connector. The design incorporates an integrated flange at the bottom of the connector and a notch at the edge of the hole. Through pull-out model tests on four notched T-perfobond connectors, this research investigates their failure mechanisms and pull-out capacities. Utilizing the explicit dynamics method in ABAQUS, a finite-element model of the pull-out resistance test for notched T-perfobond connectors is established and verified against experimental data. Furthermore, a detailed parametric analysis involving 54 models is conducted, examining crucial parameters such as rib dimensions, hole geometry, flange size, notch width, bar diameter, and material properties. Based on the combined experimental and numerical results, this paper assesses the suitability of current formulas for calculating the pull-out capacity of perfobond connectors and proposes a refined calculation method specifically for notched T-perfobond connectors. All the findings reported in this paper can serve as a reference in the design and construction of composite structures.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete · Structural Engineering and Vibration Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Civil Engineering, Huaqiao University, Xiamen 361021, China

Key Laboratory for Intelligent Infrastructure and Monitoring of Fujian Province, Huaqiao University, Xiamen 361021, China

Department of Bridge Engineering, Tongji University, Shanghai 200092, China

Funding

Natural Science Foundation of China · Fujian Provincial Natural Science Foundation of China · Promotion Program for Young and Middle-aged Teacher in Science and Technology Research of Huaqiao University · Huaqiao University Scientific Research Funding · College Students’ Innovation and Entrepreneurship Training Program Project

References (27)

Show source-provided references
1. Effective width evaluation for HSS-UHPC composite beams with perfobond strip connectors10.1016/j.engstruct.2023.116828 ↗
2. Experimental and analytical investigation on shear mechanism of steel-UHPC composite T-perfobond connectors10.1016/j.engstruct.2023.116061 ↗
3. Tensile stiffness of perfobond rib connectors in steel–concrete composite pylon of bridges10.1016/j.engstruct.2023.115931 ↗
4. Experimental investigation on mechanical behavior of T-type perfobond rib shear connectors under combined shear and tension10.1016/j.jobe.2023.106840 ↗
5. Experimental evaluation of the structural response of perfobond connectors10.1016/j.engstruct.2010.02.031 ↗
6. Experimental study of perfobond connectors in composite construction10.1016/j.jcsr.2012.11.002 ↗
7. Pull-Out Resistance Capacity of a New perfobond connector for Steel Pile Cap Strengthening10.1155/2016/1374689 ↗
8. Push-out tests for perfobond strip connectors with UHPC grout in the joints of steel-concrete hybrid bridge girders10.1016/j.engstruct.2017.01.008 ↗
9. Push-out test of large perfobond connectors in steel–concrete joints of hybrid bridges10.1016/j.jcsr.2018.09.002 ↗
10. Zheng, S., Liu, Y., Liu, Y., and Zhao, C. (2019). Experimental and parametric study on the pull-out resistance of a notched perfobond connector. Appl. Sci., 9.10.3390/app9040764 ↗
11. Numerical analysis of push-out specimens with perfobond rib connectors10.1016/S0045-7949(96)00270-2 ↗
12. Finite element simulation and parametric studies of perfobond rib connector10.3844/ajassp.2007.122.127 ↗
13. Parametric study on shear capacity of circular-hole and long-hole perfobond connector10.1016/j.jcsr.2015.09.012 ↗
14. Numerical simulation of Y-type perfobond rib shear connectors using finite element analysis
15. Karam, M.S., Yamamoto, Y., Nakamura, H., and Miura, T. (2020). Numerical evaluation of the perfobond (PBL) shear connector subjected to lateral pressure using coupled rigid body spring model (RBSM) and nonlinear solid finite element method (FEM). Crystals, 10.10.3390/cryst10090743 ↗
16. Ultimate shear strength of perfobond connectors subjected to fully reversed cyclic loading10.1016/j.engstruct.2021.113240 ↗
17. Experimental assessment of Perfobond and T-perfobond connectors’ structural response10.1016/j.jcsr.2008.02.011 ↗
18. An analytical study on dynamic strength evaluation of perfobond strip shear connectors10.4028/www.scientific.net/AMM.566.179 ↗
19. Shear behavior and analytical model of perfobond connectors10.12989/scs.2016.20.1.071 ↗
20. Zheng, S., Zhao, C., and Liu, Y. (2018). Analytical model for load–slip relationship of perfobond connector based on push-out test. Materials, 12.10.3390/ma12010029 ↗
21. Experimental and analytical investigation on pull-out performance of multihole thin-rib perfobond connectors10.1061/(ASCE)BE.1943-5592.0001400 ↗
22. Investigation on structural performance of perfobond strip connector group in steel-concrete joints10.1016/j.engstruct.2021.112571 ↗
23. Static behavior of small-rib-height perfobond connectors embedded in UHPC: Experimental and analytical studies10.1016/j.jobe.2024.108750 ↗
24. Three failure modes of high-strength steel (HSS) perfobond connector embedded in UHPC10.1016/j.engstruct.2023.116147 ↗
25. Experimental study on flexural performance of HSS-UHPC composite beams with perfobond strip connectors10.1061/(ASCE)ST.1943-541X.0003366 ↗
26. Dassault System (2010). ABAQUS Documentation, Version 6.10, Dassault System.
27. Tensile and tensile fatigue behaviour of concrete; experiments, modelling and analyses