Test-Retest and Inter-Rater Reliability of a Rotary Axis Encoder-Flywheel System for the Assessment of Hip Rotation Exercises
Source abstract
Abstract
Background: Flywheel devices have found extensive use as a resistance training method. Performance monitoring during functional exercises can be achieved through a coupled rotary axis encoder. However, the reliability of a rotary axis encoder-flywheel system remains underexplored for isolated movements. This study aims to assess test-retest and inter-rater reliability of a rotary axis encoder-flywheel system for assessing hip rotation movements. Methods: Twenty-nine physically active participants were included. The Conic Power Move® flywheel was used to perform hip internal and external rotation exercises. Mean and peak values for velocity, force, and power were collected using a Chronojump rotary axis encoder and the Chronojump software v.2.2.1. The intraclass correlation coefficient (ICC) and the coefficient of variation (CV) were calculated to assess relative and absolute reliability, respectively. Standard error of measurement and minimum detectable changes were also calculated. Results: Good to excellent ICCs (0.85–0.98) were achieved for test-retest and inter-rater reliability in all outcomes for both hip internal and external rotation exercises. There was acceptable test-retest absolute reliability (CV < 10%) for mean and peak velocity, and mean force of hip internal and external rotation (CV = 4.7–7%). Inter-rater absolute reliability was acceptable for mean and peak velocity, mean power, and mean force (CV = 4.7–9.8%). Conclusion: The rotational encoder-flywheel system demonstrated good to excellent relative reliability for assessing hip rotation exercises. Peak force and power values exhibit absolute reliability >10%, so the use of mean and peak velocity, mean force, and mean power seems more adequate for measurements with the rotary axis encoder-flywheel system.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Lower Extremity Biomechanics and Pathologies · Hip disorders and treatments · Sports injuries and prevention
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Health Sciences, University of Valladolid, C/Universidad s/n., 42004 Soria, Spain
Clinical Research in Health Sciences Group, Department of Surgery, Ophthalmology, Otorhinolaryngology and Physiotherapy, University of Valladolid, C/Universidad s/n., 42004 Soria, Spain
References (39)
Show source-provided references
1. Testing strength and power in soccer players: The application of conventional and traditional methods of assessment10.1519/JSC.0000000000000807 ↗
2. Effects of Different Inertial Load Settings on Power Output Using a Flywheel Leg Curl Exercise and its Inter-Session Reliability10.2478/hukin-2020-0029 ↗
3. Mentiplay, B.F., Perraton, L.G., Bower, K.J., Adair, B., Pua, Y.H., Williams, G.P., McGaw, R., and Clark, R.A. (2015). Assessment of lower limb muscle strength and power using hand-held and fixed dynamometry: A reliability and validity study. PLoS ONE, 10.10.1371/journal.pone.0140822 ↗
4. Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis10.1515/med-2017-0052 ↗
5. Intrarater reliability of hand held dynamometry in measuring lower extremity isometric strength using a portable stabilization device10.1016/j.math.2016.07.010 ↗
6. Standardised measurement of physical capacity in young and middle-aged active adults with hip-related pain: Recommendations from the first International Hip-related Pain Research Network (IHiPRN) meeting, Zurich, 201810.1136/bjsports-2019-101457 ↗
7. Validity and reliability of a flywheel squat test in sport10.1080/02640414.2020.1827530 ↗
8. Post-activation potentiation (PAP) in endurance sports: A review10.1080/17461391.2018.1438519 ↗
9. Validity of the iLOAD® app for resistance training monitoring
10. Maroto-Izquierdo, S., Nosaka, K., Alarcón-Gómez, J., and Martín-Rivera, F. (2023). Validity and Reliability of Inertial Measurement System for Linear Movement Velocity in Flywheel Squat Exercise. Sensors, 23.10.3390/s23042193 ↗
11. Flywheel Training Periodization in Team Sports10.3389/fphys.2021.732802 ↗
12. Use of concentric linear velocity to monitor flywheel exercise load10.3389/fphys.2022.961572 ↗
13. Muñoz-López, A., De Souza Fonseca, F., Ramírez-Campillo, R., Gantois, P., Javier Nuñez, F., and Nakamura, F.Y. (2021). The use of real-time monitoring during flywheel resistance training programmes: How can we measure eccentric overload? A systematic review and meta-analysis. Biol. Sport, 38.10.5114/biolsport.2021.101602 ↗
14. Clinical Applications of Iso-Inertial, Eccentric-Overload (YoYoTM) Resistance Exercise10.3389/fphys.2017.00241 ↗
15. Load Quantification and Testing Using Flywheel Devices in Sports10.3389/fphys.2021.739399 ↗
16. The Flywheel Leg-Curl Machine: Offering Eccentric Overload for Hamstring Development10.1123/ijspp.1.3.293 ↗
17. Eccentric Strength Assessment of Hamstring Muscles with New Technologies: A Systematic Review of Current Methods and Clinical Implications10.1186/s40798-021-00298-7 ↗
18. Spudić, D., Smajla, D., and Šarabon, N. (2020). Intra-session reliability of electromyographic measurements in flywheel squats. PLoS ONE, 15.10.1371/journal.pone.0243090 ↗
19. Ryan, S., Ramirez-Campillo, R., Browne, D., Moody, J.A., and Byrne, P.J. (2023). Intra- and Inter-Day Reliability of Inertial Loads with Cluster Sets When Performed during a Quarter Squat on a Flywheel Device. Sports, 11.10.3390/sports11060121 ↗
20. Test–retest reliability of cardinal plane isokinetic hip torque and EMG10.1016/j.jelekin.2008.07.005 ↗
21. Hip kinematics during single leg tasks in people with and without hip-related groin pain and the association among kinematics, hip muscle strength and bony morphology10.2519/jospt.2020.9150 ↗
22. Which exercises target the gluteal muscles while minimizing activation of the tensor fascia lata? Electromyographic assessment using fine-wire electrodes10.2519/jospt.2013.4116 ↗
23. Core Stability and Hip Exercises Improve Physical Function and Activity in Patients with Non-Specific Low Back Pain: A Randomized Controlled Trial10.1620/tjem.251.193 ↗
24. The relationship of hip rotation range, hip rotator strength and balance in healthy individuals10.3233/BMR-181299 ↗
25. The influence of abnormal hip mechanics on knee injury: A biomechanical perspective10.2519/jospt.2010.3337 ↗
26. Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed10.1016/j.jclinepi.2010.03.002 ↗
27. A Web-based Sample Size Calculator for Reliability Studies10.21315/eimj2018.10.3.8 ↗
28. Los Sesgos en Investigación Clínica10.4067/S0717-95022015000300056 ↗
29. Quantification of the forearm muscles mechanical properties using Myotonometer: Intra- and Inter-Examiner reliability and its relation with hand grip strength10.1016/j.jelekin.2022.102718 ↗
30. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research10.1016/j.jcm.2016.02.012 ↗
31. What is the best method for assessing lower limb force-velocity relationship?10.1055/s-0034-1385886 ↗
32. Validity of Various Methods for Determining Velocity, Force, and Power in the Back Squat10.1123/ijspp.2016-0627 ↗
33. Reliability and validity assessment of a linear position transducer
34. Reliability and validity of a linear position transducer for measuring jump performance
35. Effects of adding a weekly eccentric-overload training session on strength and athletic performance in team-handball players10.1080/17461391.2017.1282046 ↗
36. Characterising overload in inertial flywheel devices for use in exercise training10.1080/14763141.2018.1433715 ↗
37. The Flywheel Device Shaft Shape Determines Force and Velocity Profiles in The Half Squat Exercise10.2478/hukin-2022-0002 ↗
38. Influence of Different Inertial Loads on Basic Training Variables during the Flywheel Squat Exercise10.1123/ijspp.2017-0282 ↗
39. Reliability of work-related assessments