journal article·2020-03-01Open access

Additive manufacturing in radiation oncology: a review of clinical practice, emerging trends and research opportunities

Rance Tino, Martin Leary, Adam Yeo, Elizabeth Kyriakou, Tomas Kron, Milan Brandt

Abstract

Abstract The additive manufacturing (AM) process plays an important role in enabling cross-disciplinary research in engineering and personalised medicine. Commercially available clinical tools currently utilised in radiotherapy are typically based on traditional manufacturing processes, often leading to non-conformal geometries, time-consuming manufacturing process and high costs. An emerging application explores the design and development of patient-specific clinical tools using AM to optimise treatment outcomes among cancer patients receiving radiation therapy. In this review, we: • highlight the key advantages of AM in radiotherapy where rapid prototyping allows for patient-specific manufacture • explore common clinical workflows involving radiotherapy tools such as bolus, compensators, anthropomorphic phantoms, immobilisers, and brachytherapy moulds; and • investigate how current AM processes are exploited by researchers to achieve patient tissue-like imaging and dose attenuations. Finally, significant AM research opportunities in this space are highlighted for their future advancements in radiotherapy for diagnostic and clinical research applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Radiotherapy Techniques · Anatomy and Medical Technology · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (98)

Show source-provided references
1. Stereolithographic biomodelling in surgery10.14264/uql.2018.730 ↗
2. Bionic mechanical design of titanium bone tissue implants and 3D printing manufacture10.1016/j.matlet.2017.04.128 ↗
3. Anatomical reproducibility through 3D printing in cranio-maxillo-facial defects10.4067/S0717-95022015000300003 ↗
4. Next-generation biomedical implants using additive manufacturing of complex, cellular and functional mesh arrays10.1098/rsta.2010.0010 ↗
5. Fabrication methods of porous metals for use in orthopaedic applications10.1016/j.biomaterials.2005.12.002 ↗
6. Development of individual three-dimensional bone substitutes using ‘selective laser melting’10.1007/s00068-003-1332-2 ↗
7. Applications of additive manufacturing in dentistry: a review10.1002/jbm.b.33961 ↗
8. Selective laser melting in dentistry
9. Direct digital manufacturing of complex dental prostheses10.1007/978-0-387-47683-4_7 ↗
10. Rapid manufacture of removable partial denture frameworks10.1108/13552540610652438 ↗
11. A TPMS-based method for modeling porous scaffolds for bionic bone tissue engineering10.1038/s41598-018-25750-9 ↗
12. 3D printing of bone tissue engineering scaffolds10.3969/j.issn.2095-4344.2015.25.027 ↗
13. New paradigms in internal architecture design and freeform fabrication of tissue engineering porous scaffolds10.1016/j.medengphy.2012.05.008 ↗
14. Mathematically defined tissue engineering scaffold architectures prepared by stereolithography10.1016/j.biomaterials.2010.05.068 ↗
15. Engineering functionally graded tissue engineering scaffolds10.1016/j.jmbbm.2007.11.002 ↗
16. Solid freeform fabrication of three-dimensional scaffolds for engineering replacement tissues and organs10.1016/S0142-9612(03)00030-9 ↗
17. Fused deposition modeling of novel scaffold architectures for tissue engineering applications10.1016/S0142-9612(01)00232-0 ↗
18. The use of wedge filters to improve dose distribution with the partial rotation technique10.1148/117.2.441 ↗
19. The effects of cutouts on output, mean energy and percentage depth dose of 12 and 14 MeV electrons10.4103/0971-6203.89970 ↗
20. Assessment of skin dose for breast chest wall radiotherapy as a function of bolus material10.1088/0031-9155/53/10/010 ↗
21. Design of compensators for breast radiotherapy using electronic portal imaging10.1016/0167-8140(95)01617-P ↗
22. Immobilizing and positioning patients for radiotherapy10.1016/S1053-4296(95)80004-2 ↗
23. Fractionated high dose rate brachytherapy moulds—a precise treatment for carcinoma of the pinna10.1016/S0167-8140(98)00059-0 ↗
24. Design and implementation of an anthropomorphic quality assurance phantom for intensity-modulated radiation therapy for the radiation therapy oncology group10.1016/j.ijrobp.2005.05.021 ↗
25. The tissue-equivalence of the Alderson Rando anthropomorphic phantom for x-rays of diagnostic qualities10.1088/0031-9155/26/1/013 ↗
26. Anthropomorphic phantoms
27. Anatomically and functionally accurate soft tissue phantoms and method for generating same
28. Khan · 2012
29. Quality assurance in radiotherapy. European society for therapeutic radiology and oncology advisory report to the commission of the European union for the ‘Europe against cancer programme10.1016/0167-8140(95)01549-V ↗
30. The ESTRO-QUALity assurance network (EQUAL)10.1016/S0167-8140(99)00101-2 ↗
31. Critical impact of radiotherapy protocol compliance and quality in the treatment of advanced head and neck cancer: results from TROG 02.0210.1200/JCO.2009.27.4498 ↗
32. Treatment planning method and apparatus for radiosurgery and radiation therapy
33. New technique for developing a proton range compensator with use of a 3-dimensional printer10.1016/j.ijrobp.2013.10.024 ↗
34. A customized bolus produced using a 3-dimensional printer for radiotherapy10.1371/journal.pone.0110746 ↗
35. Individualized 3D scanning and printing for non-melanoma skin cancer brachytherapy: a financial study for its integration into clinical workflow10.5114/jcb.2017.68134 ↗
36. Patient specific 3D printed phantom for IMRT quality assurance10.1088/0031-9155/59/19/5763 ↗
37. A framework for clinical commissioning of 3D-printed patient support or immobilization devices in photon radiotherapy10.1002/acm2.12408 ↗
38. A feasibility study for using ABS plastic and a low-cost 3D printer for patient-specific brachytherapy mould design10.1007/s13246-015-0356-3 ↗
39. Effects on skin dose from unwanted air gaps under bolus in photon beam radiotherapy10.1016/S1350-4487(99)00276-0 ↗
40. System and method for manufacturing bolus for radiotherapy using a three-dimensional printer
41. Clinical implementation of 3D printing in the construction of patient specific bolus for electron beam radiotherapy for non-melanoma skin cancer10.1016/j.radonc.2016.07.011 ↗
42. Use of 3D printers to create a patient-specific 3D bolus for external beam therapy10.1120/jacmp.v16i3.5247 ↗
43. Workload implications for clinic workflow with implementation of three-dimensional printed customized bolus for radiation therapy: a pilot study10.1371/journal.pone.0204944 ↗
44. Utilization of a 3D printer to fabricate boluses used for electron therapy of skin lesions of the eye canthi10.1002/acm2.12013 ↗
45. A patient-specific polylactic acid bolus made by a 3D printer for breast cancer radiation therapy10.1371/journal.pone.0168063 ↗
46. Design and production of 3D printed bolus for electron radiation therapy10.1120/jacmp.v15i4.4831 ↗
47. Dosimetric characterization of 3D printed bolus at different infill percentage for external photon beam radiotherapy10.1016/j.ejmp.2017.06.004 ↗
48. 3D printed bolus with flexible materials: treatment planning accuracy and practical aspects10.1016/j.ijrobp.2017.06.2279 ↗
49. Bio-compatible patient-specific elastic bolus for clinical implementation10.1088/1361-6560/ab1c93 ↗
50. 2019
51. Tissue compensators made of solid water or lead for megavoltage x-ray radiotherapy10.1016/0958-3947(89)90137-4 ↗
52. Polyethylene-lead tissue compensators for megavoltage radiotherapy10.1016/S0958-3947(98)90108-X ↗
53. Compensators: an alternative IMRT delivery technique10.1120/jacmp.v5i3.1965 ↗
54. Tungsten filled 3D printed field shaping devices for electron beam radiation therapy10.1371/journal.pone.0217757 ↗
55. Proton therapy—present and future10.1016/j.addr.2016.11.006 ↗
56. A depth-sensing technique on 3D-printed compensator for total body irradiation patient measurement and treatment planning10.1118/1.4964452 ↗
57. Total body irradiation with a compensator fabricated using a 3D optical scanner and a 3D printer10.1088/1361-6560/aa6866 ↗
58. Use of 3D-printers to create intensity-modulated radiotherapy compensator blocks10.1109/EMBC.2012.634729 ↗
59. Potential of 3D printing technologies for fabrication of electron bolus and proton compensators10.1120/jacmp.v16i3.4959 ↗
60. 2019
61. 2019
62. A systematic review on 3D-printed imaging and dosimetry phantoms in radiation therapy10.1177/1533033819870208 ↗
63. Recent advances on the development of phantoms using 3D printing for imaging with CT, MRI, PET, SPECT, and ultrasound10.1002/mp.13058 ↗
64. Using 3D printing techniques to create an anthropomorphic thorax phantom for medical imaging purposes10.1002/mp.12644 ↗
65. Three-dimensional printer-generated patient-specific phantom for artificial in vivo dosimetry in radiotherapy quality assurance10.1016/j.ejmp.2017.10.005 ↗
66. Evaluation of 3D printing materials for fabrication of a novel multi-functional 3D thyroid phantom for medical dosimetry and image quality10.1016/j.radphyschem.2017.02.009 ↗
67. Feasibility of a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance of intensity-modulated radiotherapy10.1371/journal.pone.0181560 ↗
68. Development of a 3D printed anthropomorphic lung phantom for image quality assessment in CT10.1016/j.ejmp.2018.11.015 ↗
69. 3D printer generated thorax phantom with mobile tumor for radiation dosimetry10.1063/1.4923294 ↗
70. Paper-based 3D printing of anthropomorphic CT phantoms: feasibility of two construction techniques10.1007/s00330-018-5654-1 ↗
71. A radiopaque 3D printed, anthropomorphic phantom for simulation of CT-guided procedures10.1007/s00330-018-5481-4 ↗
72. Technical Note: an algorithm and software for conversion of radiotherapy contour-sequence data to ready-to-print 3D structures10.1002/mp.13452 ↗
73. Additive manufacture of custom radiation dosimetry phantoms: an automated method compatible with commercial polymer 3D printers10.1016/j.matdes.2015.07.052 ↗
74. Additive manufacture of lung equivalent anthropomorphic phantoms: a method to control hounsfield number utilizing partial volume effect10.1115/1.4044460 ↗
75. Gyroid structures for 3D-printed heterogeneous radiotherapy phantoms10.1088/1361-6560/ab48ab ↗
76. A novel 3D printing method for accurate anatomy replication in patient-specific phantoms10.1002/mp.13154 ↗
77. An anthropomorphic phantom representing a prematurely born neonate for digital x-ray imaging using 3D printing: proof of concept and comparison of image quality from different systems10.1038/s41598-019-50925-3 ↗
78. Dosimetric evaluation of respiratory gated volumetric modulated arc therapy for lung stereotactic body radiation therapy using 3D printing technology10.1371/journal.pone.0208685 ↗
79. A new system for patient fixation in radiotherapy10.1016/S0167-8140(87)80168-8 ↗
80. Personalized fixation using a vacuum consolidation technique10.1259/0007-1285-54-639-257 ↗
81. Whole-body-casts for patient immobilization in mantle treatment, treatment of the inverted-Y and moving strip10.1016/0360-3016(77)90068-2 ↗
82. Positioning and immobilization device for patients receiving radiation therapy for carcinoma of the breast10.1016/0958-3947(90)90059-Q ↗
83. Positioning and immobilization of patients undergoing radiation therapy for Hodgkin’s disease10.1016/0958-3947(91)90120-Q ↗
84. A modification of the HS3 thoracic Alpha Cradle for breast/chestwall patients10.1016/0958-3947(90)90063-N ↗
85. Technical aspects in the use of ‘belly boards’ for small bowel minimization10.1016/0958-3947(90)90061-L ↗
86. Medulloblastoma immobilization and treatment considerations10.1016/0958-3947(90)90060-U ↗
87. Alpha cradles in breast cancer treatment: easy immobilization for the potentially difficult breast set up10.1016/0958-3947(90)90064-O ↗
88. Clinical applications of patient’s positioning and immobilization using the rigid urethane foam
89. Improvement of the immobilization method in combination with a rigid urethane foam supporter and a thermoplastic cast
90. Development of the head and neck immobilization device, using rigid polyurethane foam
91. The use of thermal plastics for immobilization10.1016/0360-3016(82)90601-0 ↗
92. Simple but sophisticated immobilization casts10.1016/0360-3016(78)90027-5 ↗
93. Treatment planning with head and neck immobilization shell
94. Precise positioning of patients for radiation therapy10.1016/0360-3016(82)90530-2 ↗
95. Immobilization and reproducibility in radiotherapy for cancer of the larynx and pharynx using simplified shell and bite-block
96. On-line radiotherapy imaging with an array of fiber-optic image reducers10.1016/0360-3016(90)90324-D ↗
97. Current status of cranial stereotactic radiosurgery in the UK10.1259/bjr.20150452 ↗
98. Psychological functioning in cancer patients treated with radiotherapy10.1016/S0738-3991(03)00021-1 ↗