journal article·2023-06-14Open access

Optimal Buccal Site for Mini-Implant Placement on Attached Gingiva of Posterior Maxilla: A CBCT Study

Georgios Vasoglou, Konstantinos Apostolopoulos, Michail Vasoglou

Applied Sciences· Volume 13· Issue 12

Abstract

This research aims to investigate the optimal buccal site on the attached gingiva of the posterior maxilla for mini-implant placement for anchorage purposes in orthodontics. In 23 female patients, mini-implants were implemented between the roots of the first molar and second premolar, in the maxilla, for anchorage purposes. A CBCT was acquired for diagnostic purposes, and intraoral scanning was performed. Using the digital model that was the result of combining the DICOM and STL files, the cortical bone thickness and density, as well as the trabecular bone density, were measured on three axial bone slices corresponding to the three defined height levels (lower, middle, upper) on the attached gingiva, in the interradicular area. Pearson and eta correlation tests were performed in order to investigate possible correlations between height in the attached gingiva, and the corresponding cortical bone thickness and density, as well as the corresponding trabecular bone density. The correlations regarding the height level in the attached gingiva were medium for the cortical bone thickness, and weak for the cortical bone density, while a strong correlation was found between the cortical bone thickness and density. The upper level of the attached gingiva, between the second premolar and the first molar in the maxilla, is the optimal site for mini-implant placement, as the cortical bone thickness and density are probably greater than in the lower and middle level.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Dental Implant Techniques and Outcomes · Dental Radiography and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Private Orthodontic Practice, 17676 Athens, Greece

Orthodontics Department, School of Dental Medicine, Case Western Reserve University, Cleveland, OH 44106, USA

Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, 11527 Athens, Greece

References (55)

Show source-provided references
1. Mini-implant for orthodontic anchorage
2. Miniscrews as orthodontic anchorage: A preliminary report
3. Immediate loading of implants used for orthodontic anchorage10.1034/j.1600-0544.2000.030105.x ↗
4. Development of orthodontic micro-implants for intraoral anchorage
5. Influence of cortical bone thickness and implant length on implant stability at the time of surgery-clinical, prospective, biomechanical, and imaging study10.1016/j.bone.2005.06.019 ↗
6. Insertion Angle Impact on Primary Stability of Orthodontic Mini-Implants10.2319/100707-484.1 ↗
7. Parameters Affecting Primary Stability of Orthodontic Mini-implants10.1007/s00056-006-0611-z ↗
8. Resonance frequency analysis and damping capacity assessment. Part 2: Peri-implant bone loss follow-up. An in vitro study with the Periotest and Osstell instruments10.1111/j.1600-0501.2005.01174.x ↗
9. A Newly Designed Resonance Frequency Analysis Device for Dental Implant Stability Detection10.4012/dmj.26.665 ↗
10. Design of a stability-detecting device for dental implants10.1243/095441105X9336 ↗
11. Resonance frequency analysis measurements of implants at placement surgery
12. Relationships between bone density values from cone beam computed tomography, maximum insertion torque, and resonance frequency analysis at implant placement: A pilot study
13. In Vitro Assessment of Primary Stability of Straumann® Implant Designs10.1111/j.1708-8208.2012.00464.x ↗
14. Correlation of cone beam CT-derived bone density parameters with primary implant stability assessed by peak insertion torque and periotest in the maxilla10.1016/j.jcms.2019.01.002 ↗
15. The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone10.1016/j.ijom.2008.09.006 ↗
16. Risks and complications of orthodontic miniscrews10.1016/j.ajodo.2006.04.027 ↗
17. Effects of cortical bone thickness and rabecular bone density on primary stability of orthodontic mini-implants10.1016/j.jds.2019.06.002 ↗
18. Correlating implant stability to bone structure10.1111/j.1600-0501.2009.01745.x ↗
19. A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results10.1007/s003300050586 ↗
20. Cone-beam computed tomography and three-dimensional orthodontics. Where we are and future perspectives10.1177/1465312519840029 ↗
21. Comparison of two cone beam computed tomographic systems versus panoramic imaging for localization of impacted maxillary canines and detection of root resorption10.1093/ejo/cjq034 ↗
22. Kapila, S. (2014). Cone Beam Computed Tomography in Orthodontics: Indications, Insights and Innovations, Wiley-Blackwell.10.1002/9781118674888 ↗
23. Quantitative evaluation of cortical bone thickness with computed tomographic scan-ning for orthodontic implants10.1016/j.ajodo.2006.02.026 ↗
24. Quantitative CBCT evaluation of maxillary and mandibular cortical bone thickness and density variability for ortho-dontic miniplate placement
25. Buccal cortical bone thickness for mini-implant placement10.1016/j.ajodo.2007.10.045 ↗
26. Cortical bone thickness in the buccal posterior region for orthodontic mini-implants10.1016/j.ijom.2008.01.005 ↗
27. Quantitative evaluation of maxillary interradicular bone with cone-beam computed tomography for bicortical placement of orthodontic mini-implants10.1016/j.ajodo.2015.02.018 ↗
28. Optimal sites for orthodontic mini-implant placement assessed by cone beam computed tomography10.2319/121009-709.1 ↗
29. Bone classification: An objective scale of bone density using the computerized tomography scan10.1034/j.1600-0501.2001.012001079.x ↗
30. Bone density assessments of oral implant sites using computerized tomography10.1111/j.1365-2842.2006.01689.x ↗
31. Bone density assessments of dental implant sites: 2. Quantitative cone-beam computerized tomography
32. Bone density changes around teeth during orthodontic treatment10.1007/s00784-010-0410-1 ↗
33. Evaluation of relationship between preoperative bone density values derived from cone beam computed tomography and implant stability parameters: A clinical study10.1111/clr.12219 ↗
34. Assessment of Maxillary Bone Density by the Tomodensitometric Scale in Cone-Beam Computed Tomography (CBCT)
35. Assessment of jaw bone density in terms of Hounsfield units using cone beam computed tomography for dental implant treatment planning10.51253/pafmj.v71i1.3907 ↗
36. Misch, C.E. Density of bone: Effect on treatment planning, surgical approach, and healing. Proceedings of the Contemporary Implant Dentistry.
37. Hard and soft tissue considerations at mini-implant insertion sites10.1179/1465313314Y.0000000104 ↗
38. Newman, M.G., Takeim, H., Klokkevold, P.R., and Carranza, F.A. (2006). Carranza’s Clinical Periodontology, Saunders Publishers. [10th ed.].
39. Surgical extension of vestibular depth. On the results in various regions of the mouth in periodontal patients
40. Assessment of the width of attached gingiva using different methods in various age groups: A clinical study10.4103/0972-124X.152106 ↗
41. Intra- and Inter-Examiner Reproducibility in Keratinized Tissue Width Assessment with 3 Methods for Mucogingival Junction Determination10.1902/jop.2001.72.2.134 ↗
42. Hulley, S.B., Cummings, S.R., Browner, W.S., Grady, D., and Newman, T.B. (2013). Designing Clinical Research: An Epidemiologic Approach, Lippincott Williams & Wilkins. [4th ed.].
43. Soft-tissue and cortical-bone thickness at orthodontic implant sites10.1016/j.ajodo.2004.12.024 ↗
44. Assessment of the cortical bone thickness by CT-scan and its association with orthodontic implant position in a young adult Eastern Mediterranean population: A cross sectional study10.1016/j.ortho.2020.02.001 ↗
45. Cortical bone thickness of the alveolar process measured with cone-beam computed tomography in patients with different facial types10.1016/j.ajodo.2012.09.013 ↗
46. Cortical bone thickness at common miniscrew implant placement sites10.1016/j.ajodo.2009.03.057 ↗
47. Evaluation of alveolar cortical bone thickness and density for orthodontic mini-implant placement10.4317/jced.51228 ↗
48. Analysis of CBCT Bone Density Using the Hounsfield Scale10.3390/prosthesis4030033 ↗
49. Cone-beam computed tomography and digital model analysis of maxillary buccal alveolar bone thickness for vertical temporary skeletal anchorage device placement10.1016/j.ajodo.2021.12.013 ↗
50. Interradicular sites and cortical bone thickness for miniscrew insertion: A systematic review with meta-analysis10.1016/j.ajodo.2020.05.011 ↗
51. A CBCT atlas of buccal cortical bone thickness in interradicular spaces10.2319/082214-593.1 ↗
52. Analysis of intensity variability in multislice and cone beam computed tomography10.1111/j.1600-0501.2010.02076.x ↗
53. Bone mineral density in cone beam computed tomography: Only a few shades of gray10.4329/wjr.v6.i8.607 ↗
54. Assessments of jaw bone density at implant sites using 3D cone-beam computed to-mography
55. Cortical bone thickness and density: Inter-relationship at different orthodontic implant positions10.1080/13440241.2021.2024013 ↗