Study on Transverse Seismic Response Characteristics of Large Diameter Vertical Double-Layer Overlapping Pipe Jacking in the Soil-Rock Composite Stratum
Source abstract
Abstract
The sharp change of stiffness in the soil–rock combination stratum is the weak point in the seismic design of the pipe jacking structure. To study the seismic response characteristics of vertical double-layer overlapping pipe jacking, based on the typical soil–rock combination strata in Jinan, two electric power pipe jacking tunnels of 3.6 m diameter were studied as the research objects, where the upper pipe jacking is located in the soil and the lower pipe jacking is located in the composite stratum of half soil and half rock. The soil–rock-overlapping tunnel system was deemed as a plane strain problem. By using the dynamic time history method and considering the non-linearity of material, the seismic response characteristics of a vertical overlapping pipe jacking tunnel under seismic wave were discussed from five aspects, acceleration response, displacement response, stress response, soil interlayer response and the influence of soil–rock combination stratum. The results indicate that under the action of ground motion, the peak acceleration and relative horizontal displacement of the upper pipe jacking are greater than those of the lower pipe jacking; small pipe jacking spacing will lead to the aggravating earthquake failure effect; due to the stiffness difference, the relative horizontal displacement and stress of pipe jacking structure at the soil–rock interface change abruptly. The vertical double-layer arrangement of the pipe jacking increases the buried depth, and the stratum is prone to be uneven hardness. Therefore, the seismic design and relevant structural measures of large diameter vertical overlapping pipe jacking structure should be strengthened.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Geotechnical Engineering and Underground Structures · Geotechnical Engineering and Analysis · Geotechnical Engineering and Soil Stabilization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Civil Engineering, Shandong Jianzhu University, Jinan 250101, China
Key Laboratory of Building Structural Retrofitting and Underground Space Engineering, Ministry of Education, Jinan 250101, China
Jinan Rail Transit Group Co., Ltd., Jinan 250014, China
Funding
Key Program of National Natural Science Foundation of China · Innovation Team Development Program of the Ministry of Education
References (25)
Show source-provided references
1. Influence of construction sequence and different types of pipes on ground surface settlement caused by the construction of two-layer jacking-pipes
2. Research on varying regularity of soil vertical deformation caused by the construction of two-layer jacking-pipe
3. Seismic damage classification and risk assessment of mountain tunnels with a validation for the 2008 Wenchuan earthquake10.1016/j.soildyn.2012.11.002 ↗
4. Research progress of underground engineering seismic analysis methods and performance evaluation
5. Model test of seismic behavior of fiber concrete lining at the interface between soft and hard surrounding rock of tunnel
6. Seismic response of double-layer vertical overlapping subway tunnel under strong ground motion near fault
7. Seismic response characteristics of double-layer vertical overlapping subway tunnel subjected to near-field and far-field vibrations
8. Yang, N.B. (2013). Analysis of the Earthquake Reaction and Influencing Factors of the Shield Tunnel, Institute of Engineering Mechanics.
9. Zhang, W.J., and Yuan, D.J. (2009). Earthquake Research and Examples of Shield Tunnel, China Architecture & Building Press.
10. Yu, Y.S. (2015). Analysis of the Power Response of the Shield Tunnel under the Strong Earthquake, Dalian University of Technology.
11. Earthquake damage mechanism analysis and aseismic study of tunnel structure with soft and hard interface of soil and rock
12. Wang, W. (2015). Study on the Characteristics of the Earthquake Response Characteristics of Soft and Hard Mutations on the Earth Shield Tunnel, Southwest Jiaotong University.
13. Shaking table test of longitudinal seismic response of shield tunnel passing through soft and hard abrupt strata
14. Shaking table test and numerical simulation on ultra-large diameter shield tunnel passing through soft-hard stratum10.1016/j.soildyn.2021.106790 ↗
15. Shaking table test on the seismic response of the portal section in soft and hard rock junction
16. Analysis and research on dynamic response law and seismic measures of mountain tunnel in high intensity earthquake region
17. Finite element method accuracy for wave propagation problems10.1061/JSFEAQ.0001885 ↗
18. GTS NX (2015). General Geotechnical Finite Element Software Theoretical Analysis Manual, Beijing Midas Co., Ltd.
19. Huang, S.M., and Wang, Y.Y. (2016). Code for Seismic Design of Buildings, GB50011-2010, China Architecture and Building Press.
20. (2014). Code for Seismic Design of Urban Rail Transit Structures (Standard No. GB50909-2014).
21. (2015). Seismic Ground Motion Parameter Zonation Map of China (Standard No. GB18306-2015).
22. Study on seismic response characteristics of shield tunnel in soil-rock combination stratum10.1155/2022/7504347 ↗
23. Chen, L., Chen, G.X., and Chen, S. (2010, January 23). 3D Nonlinear Seismic Response Analysis of Intersecting MetroTunnels Under Far-Field Ground Motion of Large Earthquake. Low-carbon economy and civil engineering science and technology innovation—2011 China (Beijing) International Architectural Science and Technology Conference Paper III. Proceedings of the 10th International Conference on Contemporary Problems of Architecture and Construction, Beijing, China.
24. Seismic damage analysis of tunnel structure in Wenchuan earthquake
25. A Study of the Dynamic Response Characteristics of a Tunnel Structure Through an Interface of Soft and Hard Rock