Biomechanical Evaluation of a Novel Expandable Vertebral Augmentation System Using Human Cadaveric Vertebrae
Source abstract
Abstract
Unacceptable sagittal alignment and cement leakage are major concerns of percutaneous vertebroplasty when treating patients with painful vertebral osteoporotic compression fractures. To maintain the restored vertebral height and reduce the reliance on cement as the major stabilizer, an expandable vertebral augment system (EVA®) made of titanium alloy consisting of a rigid tube encased by a barrel with an anterior expansion mechanism was developed. The aim of the current study was to determine whether this novel design is as effective as existing procedures in terms of height restoration and biomechanical performance. Eight osteoporotic vertebrae (T12-L3) confirmed by dual-energy X-ray absorptiometry from two fresh-frozen human cadavers (70- and 72-year-old females) were used. Twenty-five percent reduced anterior wedge vertebral compression fractures were created using a material testing machine. Four randomized specimens were augmented with EVA® (Chang Gu Biotechnology Co. Ltd., Taipei city, Taiwan), and another four randomized specimens were augmented with OsseoFix® (AlphaTec Spine Inc., Carlsbad, CA, USA). The implant size and cement volume were controlled. The anterior vertebral body height (VBH) ratio and pre/postaugmented ultimate strength and stiffness were measured and compared. The mean anterior VBH restoration ratio was 8.54% in the EVA® group and 8.26% in the OsseoFix® groups. A significant difference from augmentation was measured in both groups (p < 0.05), but there was no significant difference between the EVA® and OsseoFix® groups in anterior VBH restoration. The ultimate strengths of the EVA® and OsseoFix® groups were 6071.4 ± 352.6 N and 6262.9 ± 529.2 N, respectively, both of which were statistically significantly higher than that of the intact group (4589.9 ± 474.6 N) (p < 0.05). The stiffnesses of the EVA®, OsseoFix®, and intact groups were 1087.2 ± 176.9, 1154.9 ± 168.9, and 1637.3 ± 340.8 N/mm, respectively, indicating that the stiffness was significantly higher in the intact group than in both the EVA® and OsseoFix® groups (p < 0.05). No significant differences were observed between the two augmentation procedures in height restoration or ultimate strength and stiffness. This novel EVA® system showed comparable height restoration and biomechanical performance to those of existing implants for human cadaveric osteoporotic compression fractures. Potential advantages of preventing cement posterior leakage and promoting cement interdigitation are expected with this ameliorated design.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Spinal Fractures and Fixation Techniques · Spine and Intervertebral Disc Pathology · Scoliosis diagnosis and treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Orthopedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital, Taoyuan 333, Taiwan
Department of Mechanical Engineering, Chang Gung University, Taoyuan 333, Taiwan
Department of Biomedical Engineering, Chang Gung University, Taoyuan 333, Taiwan
Funding
Ministry of Science and Technology in Taiwan
References (50)
Show source-provided references
1. Advances in Vertebral Augmentation Systems for Osteoporotic Vertebral Compression Fractures10.1155/2020/3947368 ↗
2. Clinical outcome and subsequent sequelae of cement extravasation after percutaneous kyphoplasty and vertebroplasty: A comparative review10.1177/0284185117732599 ↗
3. Management of the Elderly With Vertebral Compression Fractures10.1227/NEU.0000000000000947 ↗
4. Current Concepts in the Management of Vertebral Compression Fractures10.1007/s11916-020-00849-9 ↗
5. Treatment of osteoporotic vertebral fractures10.1016/j.otsr.2020.102779 ↗
6. Vertebroplasty and Kyphoplasty for Osteoporotic Vertebral Fractures: What Are the Latest Data?10.3174/ajnr.A5458 ↗
7. Vertebroplastie und Kyphoplastie10.1007/s00117-020-00651-z ↗
8. Vertebroplasty and Kyphoplasty10.1016/j.pmr.2022.01.008 ↗
9. Risk factors of neurological deficit and pulmonary cement embolism after percutaneous vertebroplasty10.1186/s13018-019-1459-4 ↗
10. Risk Factors for Cement Leakage After Vertebroplasty or Kyphoplasty: A Meta-Analysis of Published Evidence10.1016/j.wneu.2017.01.124 ↗
11. Baek, I.-H., Park, H.-Y., Kim, K.-W., Jang, T.-Y., and Lee, J.-S. (2021). Paraplegia due to intradural cement leakage after vertebroplasty: A case report and literature review. BMC Musculoskelet. Disord., 22.10.1186/s12891-021-04625-7 ↗
12. Comparison between vertebroplasty with high or low viscosity cement augmentation or kyphoplasty in cement leakage rate for patients with vertebral compression fracture: A systematic review and network meta-analysis10.1007/s00586-020-06636-9 ↗
13. Embolismo pulmonar asintomático secundario a fuga de cemento tras vertebroplastia10.1016/j.reuma.2019.11.006 ↗
14. Current concepts of percutaneous balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures: Evidence-based review10.4103/2319-4170.112544 ↗
15. Pain management: The rising role of interventional oncology10.1016/j.diii.2017.06.015 ↗
16. Minding the Gap in Vertebroplasty: Vertebral Body Fracture Clefts and Cement Nonunion
17. Kuo, Y.-R., Cheng, T.-A., Chou, P.-H., Liu, Y.-F., Chang, C.-J., Chuang, C.-F., Su, P.-F., Lin, R.-M., and Lin, C.-L. (2022). Healing of Vertebral Compression Fractures in the Elderly after Percutaneous Vertebroplasty—An Analysis of New Bone Formation and Sagittal Alignment in a 3-Year Follow-Up. J. Clin. Med., 11.10.3390/jcm11030708 ↗
18. Vertebroplasty comparing injectable calcium phosphate cement compared with polymethylmethacrylate in a unique canine vertebral body large defect model10.1016/j.spinee.2006.12.007 ↗
19. Biomechanical behavior of MRI-signal-inducing bone cements after vertebroplasty in osteoporotic vertebral bodies: An experimental cadaver study10.1016/j.clinbiomech.2014.03.002 ↗
20. Osseofix® System for Percutaneous Stabilization of Osteoporotic and Tumorous Vertebral Compression Fractures—Clinical and Radiological Results After 12 Months10.1055/s-0033-1355504 ↗
21. Third-generation percutaneous vertebral augmentation systems10.21037/jss.2016.02.01 ↗
22. An ex vivo biomechanical comparison of a novel vertebral compression fracture treatment system to kyphoplasty10.1016/j.clinbiomech.2011.11.001 ↗
23. Looped suture properties: Implications for multistranded flexor tendon repair10.1177/1753193413516245 ↗
24. Height restoration of osteoporotic vertebral compression fractures using different intravertebral reduction devices: A cadaveric study10.1016/j.spinee.2013.06.094 ↗
25. Biomechanical Evaluation of an Injectable Radiopaque Polypropylene Fumarate Cement for Kyphoplasty in a Cadaveric Osteoporotic Vertebral Compression Fracture Model10.1097/BSD.0b013e318040ad73 ↗
26. Local osteo-enhancement of osteoporotic vertebra with a triphasic bone implant material increases strength—A biomechanical study10.1007/s00402-020-03382-x ↗
27. Fracture care using percutaneously applied titanium mesh cages (OsseoFix®) for unstable osteoporotic thoracolumbar burst fractures is able to reduce cement-associated complications—Results after 12 months10.1186/s13018-015-0322-5 ↗
28. Cementless Fixation of Osteoporotic VCFs Using Titanium Mesh Implants (OsseoFix): Preliminary Results10.1155/2014/853897 ↗
29. Percutaneous Vertebroplasty and Kyphoplasty: Current Status, New Developments and Old Controversies10.1007/s00270-017-1779-x ↗
30. Expandable Intravertebral Implants: A Narrative Review on the Concept, Biomechanics, and Outcomes in Traumatology
31. Vertebral body stenting: A new method for vertebral augmentation versus kyphoplasty10.1007/s00586-010-1341-x ↗
32. Vertebral augmentation with the SpineJack® in chronic vertebral compression fractures with major kyphosis10.1007/s00330-018-5544-6 ↗
33. Clinical and radiological outcomes in thoracolumbar fractures using the SpineJack device. A prospective study of seventy-four patients with a two point three year mean of follow-up10.1007/s00264-019-04391-1 ↗
34. Use of the SpineJack direct reduction for treating type A2, A3 and A4 fractures of the thoracolumbar spine: A retrospective case series10.1136/neurintsurg-2021-017682 ↗
35. The implantation of a Nickel-Titanium shape memory alloy ameliorates vertebral body compression fractures: A cadaveric study
36. A biomechanical comparison of kyphoplasty using a balloon bone tamp versus an expandable polymer bone tamp in a deer spine model10.1302/0301-620X.89B2.17928 ↗
37. Efficacy of a Novel Vertebral Body Augmentation System in the Treatment of Patients with Symptomatic Vertebral Body Fractures10.1007/s00270-020-02658-4 ↗
38. Ender, S.A., Wetterau, E., Ender, M., Kühn, J.-P., Merk, H.R., and Kayser, R. (2013). Percutaneous Stabilization System Osseofix® for Treatment of Osteoporotic Vertebral Compression Fractures—Clinical and Radiological Results after 12 Months. PLoS ONE, 8.10.1371/journal.pone.0065119 ↗
39. Kyphoplasty Versus Vertebroplasty: Restoration of vertebral body height and correction of kyphotic deformity with special attention to the shape of the fractured vertebrae10.1097/BSD.0b013e318224a6e6 ↗
40. Kyphoplasty Restores the Global Sagittal Balance of the Spine Independently from Pain Reduction10.1038/s41598-020-65798-0 ↗
41. Pain, Quality of Life, and Safety Outcomes of Kyphoplasty for Vertebral Compression Fractures: Report of a Task Force of the American Society for Bone and Mineral Research10.1002/jbmr.3170 ↗
42. Does Percutaneous Vertebroplasty or Balloon Kyphoplasty for Osteoporotic Vertebral Compression Fractures Increase the Incidence of New Vertebral Fractures? A Meta-Analysis10.36076/ppj.2017.1.E13 ↗
43. A meta-analysis of the secondary fractures for osteoporotic vertebral compression fractures after percutaneous vertebroplasty10.1097/MD.0000000000025396 ↗
44. Adjacent vertebral fractures after percutaneous vertebral augmentation of osteoporotic vertebral compression fracture: A comparison of balloon kyphoplasty and vertebroplasty10.1007/s00402-010-1106-3 ↗
45. Cement injection and postoperative vertebral fractures during vertebroplasty10.1186/s13018-019-1273-z ↗
46. Xiong, Y.-C., Guo, W., Xu, F., Zhang, C.-C., Liang, Z.-P., Wu, L., Chen, S., and Zeng, X.-W. (2021). Refracture of the cemented vertebrae after percutaneous vertebroplasty: Risk factors and imaging findings. BMC Musculoskelet. Disord., 22.10.1186/s12891-021-04355-w ↗
47. Vertebroplasty Versus Kyphoplasty: Biomechanical Behavior Under Repetitive Loading Conditions10.1097/01.brs.0000231714.15876.76 ↗
48. Biomechanical Comparison of Augmentation Techniques for Insufficiency Fractures10.1097/01.brs.0000224546.29268.d1 ↗
49. Vertebral body stent augmentation to reconstruct the anterior column in neoplastic extreme osteolysis10.1136/neurintsurg-2018-014231 ↗
50. Safety and clinical performance of kyphoplasty and SpineJack® procedures in the treatment of osteoporotic vertebral compression fractures: A pilot, monocentric, investigator-initiated study10.1007/s00198-016-3494-x ↗