Design of 3D Structure Membrane for the Increased Sensitivity in Enzyme Linked Immunosorbent Assay (mELISA)
Source abstract
Abstract
The Enzyme Linked Immunosorbent Assay (ELISA) technique has been widely used for the identification and quantification of biochemical markers. The typical ELISA requires a number of washing steps to eliminate the unbound proteins which sometimes cause the desorption of protein due to their weak bonding between protein and well plate. In this study, we have developed a meshed type of plastic membrane in order to increase the reliable binding efficiency between proteins and the membrane surface, and to provide easy steps of washing. The use of our developed solid membrane has significantly increased the binding capacity of the biomolecules because this membrane ELISA (mELISA) provides 3D binding surfaces which increases the surface area when compared to the conventional 2D surface well plate. The columns were pretreated to form a self-assembled layer (SAM) on the surface for the stable conjugation of a target antibody. The SAM-coated membranes could be stored for one month without any further deterioration of stability. The measured optical density (O.D.) shows a 1.2-fold increase in IgG antigen (25 μg/mL) from the plastic membrane as compared with the conventional ELISA method. The concentrations of thyroid stimulating hormone were also monitored using the mELISA method and it shows good linearity against the concentrations.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Biosensing Techniques and Applications · Monoclonal and Polyclonal Antibodies Research · Advanced biosensing and bioanalysis techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Integrative Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul 06974, Korea
Funding
Ministry of Trade, Industry and Energy · Chung-Ang University
References (11)
Show source-provided references
1. Development of a flow-through immunoassay system10.1016/S0925-4005(98)00125-7 ↗
2. Effect of gamma ray on optical characteristics of (pmma/ps) polymer blends10.1007/s40094-017-0259-7 ↗
3. Detection of staphylococcus enterotoxin B at picogram levels using piezoelectric-excited millimeter-sized cantilever sensors10.1016/j.snb.2007.03.021 ↗
4. Specific detection of proteins using nanomechanical resonators10.1016/j.snb.2008.06.003 ↗
5. Self-assembled monolayers as the coating in a quartz piezoelectric crystal immunosensor to detect salmonella in aqueous solution10.1021/ac010655y ↗
6. Rapid detection of campylobacter coli, c. Jejuni, and salmonella enterica on poultry carcasses by using pcr-enzyme-linked immunosorbent assay10.1128/AEM.69.6.3492-3499.2003 ↗
7. Protein adsorption on polymer particles
8. Thiolated salmonella antibody immobilization onto the gold surface of piezoelectric quartz crystal10.1016/S0956-5663(98)00067-0 ↗
9. Increased sensitivity of 3d-well enzyme-linked immunosorbent assay (ELISA) for infectious disease detection using 3D-printing fabrication technology
10. Biochemical testing of the thyroid: TSH is the best and, oftentimes, only test needed – a review for primary care10.3121/cmr.2016.1309 ↗
11. TSH comparison between chemiluminescence (Architect) and electrochemiluminescence (Cobas) immunoassays: An indian population perspective10.1007/s12291-013-0339-7 ↗