Biomechanical Evaluation of Attachment and Trimline Modifications in Maxillary Molar Distalization Using Clear Aligners
Source abstract
Abstract
Upper molar distalization using clear aligners requires optimal force direction and control to ensure effective and predictable tooth movement. This study aimed to evaluate the biomechanical effects of different aligner trimline lengths (trimline ending at the gingival margin vs. 2 mm extended) and attachment designs (no attachment, vertical rectangular, 25-degree beveled vertical, and double horizontal) on maxillary first molar distalization using finite element analysis. A three-dimensional maxillary model was constructed from CBCT data, and eight different aligner configurations were simulated under identical distalizing force. The stress distribution within the periodontal ligament of the maxillary first molar and displacement of crown and root landmarks in three axes were analyzed. The models with no attachments and trimlines ending at the gingival margin exhibited the highest degree of uncontrolled tipping and uneven stress distribution. In contrast, models combining extended trimlines with either beveled vertical or double horizontal attachments demonstrated more controlled bodily movement, reduced palatal root mesial displacement, and more uniform vertical movement. Overall, extended trimlines were associated with increased total distalization and improved force transmission. These findings provide biomechanical insight into optimizing aligner configuration for upper molar distalization and may guide clinicians and manufacturers in improving treatment precision and predictability.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthodontics and Dentofacial Orthopedics · dental development and anomalies · Temporomandibular Joint Disorders
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Orthodontics, Faculty of Dentistry, Ankara Yildirim Beyazit University, Ankara 06220, Türkiye
Funding
Scientific Research Projects Coordination Unit of Ankara Yıldırım Beyazıt University, Türkiye
References (44)
Show source-provided references
1. Differential diagnosis of Class II malocclusions: Part 1. Facial types associated with Class II malocclusions10.1016/0002-9416(80)90299-7 ↗
2. Evaluation of maxillary molar distalization with the distal jet: A comparison with other contemporary methods
3. A clinical report for distalizing maxillary molars by using super-elastic wires10.1007/BF02190485 ↗
4. A cephalometric appraisal of edgewise Class II nonextraction treatment with extraoral force10.1016/0889-5406(88)90162-X ↗
5. Asymmetric maxillary expansion appliance (ABHE)10.1597/1545-1569_1993_030_0416_ameaa_2.3.co_2 ↗
6. The effects of premolar-extraction: A long-term comparison of outcomes in “clear-cut” extraction and nonextraction Class II patients
7. Treatment outcome and efficacy of an aligner technique—Regarding incisor torque, premolar derotation and molar distalization10.1186/1472-6831-14-68 ↗
8. A systematic review of the accuracy and efficiency of dental movements with Invisalign®10.4041/kjod.2019.49.3.140 ↗
9. Effectiveness of composite attachments in controlling upper-molar movement with aligners
10. The effects of lingual buttons, precision cuts, and patient-specific attachments during maxillary molar distalization with clear aligners: Comparison of finite element analysis10.1016/j.ajodo.2022.10.010 ↗
11. Treatment effects of intraoral appliances with conventional anchorage designs for non-compliance maxillary molar distalization: A literature review10.1093/ejo/cjn047 ↗
12. Miniscrew anchorage versus Class II elastics for maxillary arch distalization using clear aligners10.2319/110723-743.1 ↗
13. Computational design and engineering of polymeric orthodontic aligners10.1002/cnm.2839 ↗
14. Clear aligner orthodontic therapy of rotated mandibular round-shaped teeth: A finite element study10.2319/020719-86.1 ↗
15. Initial force systems during bodily tooth movement with plastic aligners and composite attachments: A three-dimensional finite element analysis10.2319/050714-330.1 ↗
16. Effects of variable composite attachment shapes in controlling upper molar distalization with aligners: A nonlinear finite element study
17. Rossini, G., Schiaffino, M., Parrini, S., Sedran, A., Deregibus, A., and Castroflorio, T. (2020). Upper second molar distalization with clear aligners: A finite element study. Appl. Sci., 10.10.3390/app10217739 ↗
18. Forces and moments delivered by the PET-G aligner to a maxillary central incisor for palatal tipping and intrusion10.2319/090216-666.1 ↗
19. Cowley, D.P. (2012). Effect of Gingival Margin Design on Retention of Thermoformed Orthodontic Aligners. [Master’s Thesis, University of Nevada].
20. Effect of trimming line design and edge extension of orthodontic aligners on force transmission: A 3D finite element study10.1016/j.jmbbm.2023.105741 ↗
21. Kim, W.H., Hong, K., Lim, D., Lee, J.H., Jung, Y.J., and Kim, B. (2020). Optimal position of attachment for removable thermoplastic aligner on the lower canine using finite element analysis. Materials, 13.10.3390/ma13153369 ↗
22. A biomechanical case study on the optimal orthodontic force on the maxillary canine tooth based on finite element analysis10.1631/jzus.B1700195 ↗
23. The effects of different types of periodontal ligament material models on stresses computed using finite element models10.1016/j.ajodo.2022.09.008 ↗
24. Experiment and hydro-mechanical coupling simulation study on the human periodontal ligament10.1016/j.cmpb.2013.12.011 ↗
25. The finite element method: A tool to study orthodontic tooth movement10.1177/154405910508400506 ↗
26. Effects of different distalization directions and methods on maxillary total distalization with clear aligners: A finite element study10.2319/072622-519.1 ↗
27. Effectiveness of the attachment position in molar intrusion with clear aligners: A finite element study10.1186/s12903-022-02472-z ↗
28. Intraoral ageing of aligners and attachments: Adverse effects on clinical efficiency and release of biologically-active compounds10.4041/kjod24.085 ↗
29. Biomechanics of clear aligner therapy: Assessing the influence of tooth position and flat trimline height in translational movements10.1111/ocr.12796 ↗
30. Distalization of maxillary molars with Invisalign aligners in nonextraction patients with Class II malocclusion10.1016/j.ajodo.2022.07.007 ↗
31. Orthodontic tooth movement with clear aligners
32. Relationship of the maxillary first permanent molar in normal occlusion and malocclusion: An intraoral study10.1016/0002-9416(56)90128-2 ↗
33. The problem of the rotated maxillary first permanent molar10.1016/0002-9416(61)90124-5 ↗
34. Nucera, R., Dolci, C., Bellocchio, A.M., Costa, S., Barbera, S., Rustico, L., Farronato, M., Militi, A., and Portelli, M. (2022). Effects of composite attachments on orthodontic clear aligners therapy: A systematic review. Materials, 15.10.3390/ma15020533 ↗
35. Influence of attachments and interproximal reduction on the accuracy of canine rotation with Invisalign: A prospective clinical study10.2319/0003-3219(2008)078[0682:IOAAIR]2.0.CO;2 ↗
36. Efficiency evaluation of maxillary molar distalization using Invisalign based on palatal rugae registration10.1016/j.ajodo.2021.11.012 ↗
37. Mamani, J., Sessirisombat, C., Hotokezaka, H., Yoshida, N., and Sirisoontorn, I. (2024). Effectiveness of Clear Aligners on Sequential Maxillary Molar Distalization: Discrepancy between Treatment Goal and Outcome. J. Clin. Med., 13.10.3390/jcm13144216 ↗
38. Impact of molar teeth distalization with clear aligners on occlusal vertical dimension: A retrospective study10.1186/s12903-019-0880-8 ↗
39. Park, T.H., Shen, C., Chung, C.-H., and Li, C. (2024). Vertical Control in Molar Distalization by Clear Aligners: A Systematic Review and Meta-Analysis. J. Clin. Med., 13.10.3390/jcm13102845 ↗
40. The Six Keys to Normal Occlusion10.1016/S0002-9416(72)90268-0 ↗
41. The Significance of the First Molar in Occlusion
42. Biomechanical Effects of Different Auxiliary-Aligner Designs for the Extrusion of an Upper Central Incisor: A Finite Element Analysis10.1155/2019/9687127 ↗
43. Validation of Finite Element Models for Orthodontic Aligners10.1016/j.jmbbm.2022.105404 ↗
44. Loberto, L., Perrotti, G., Testa, M., Di Carlo, S., Marzo, G., Pilloni, A., and D’Addona, A. (2023). Anchorage Loss Evaluation during Maxillary Molars Distalization Performed by Clear Aligners: A Retrospective Study on 3D Digital Casts. Appl. Sci., 13.10.3390/app13063646 ↗