journal article·2024-11-07Open access

Study on Quality Assessment Methods for Enhanced Resolution Graph-Based Reconstructed Images in 3D Capacitance Tomography

Robert Banasiak, Mateusz Bujnowicz, Anna Fabijańska

Applied Sciences· Volume 14· Issue 22

Abstract

This paper proposes a novel approach to assessing the quality of 3D Electrical Capacitance Tomography (ECT) images. Such images are typically represented as irregular graphs. Thus, image quality metrics typically used with raster images do not straightforwardly apply to them. However, given the recent advancements in Graph Convolutional Neural Networks (GCNs) for improving ECT image reconstruction, reliable Quality Assessment methods are essential for comparing the performance of different GCN models. To address this need, this paper applied some existing image quality and similarity assessment methods designed for raster images to the graph-based representation of 3D ECT images. Specifically, attention was paid to the Peak Signal-to-Noise Ratio (PSNR), the Structural Similarity Index Measure (SSIM), and measures based on image histograms. The proposed adaptations resulted in the development of tailored Graph Quality Assessment (GQA) techniques specifically designed for the graph-based nature of ECT images. The proposed GQA techniques were validated on 1042 phantoms and their corresponding Low-Quality (LQ) and High-Quality (HQ) reconstructions through a robust GQA benchmarking system, enabling a systematic comparison of various GQA methods. The evaluation of the proposed methods’ performances across this diverse dataset, by analyzing overall trends and specific case studies, is presented and discussed. Finally, we present our conclusions regarding the effectiveness of the proposed GQA methods, and we identify the most promising approach for assessing the quality of graph-based ECT images.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrical and Bioimpedance Tomography · Advanced X-ray and CT Imaging · Advanced MRI Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Applied Computer Science, Lodz University of Technology, 18 Stefanowskiego Str., 90-537 Lodz, Poland

Institute of Information Technology, Lodz University of Technology, 8 Al. Politechniki Str., 93-590 Lodz, Poland

References (26)

Show source-provided references
1. Yang, W., Ren, Z., Takei, M., and Yao, J. (2018, January 16–18). Medical applications of electrical tomography. Proceedings of the 2018 IEEE International Conference on Imaging Systems and Techniques (IST), Krakow, Poland.10.1109/IST.2018.8577200 ↗
2. Huang, J., Chen, F., Wang, K., and Chen, S. (2024). Research on electrical capacitance tomography (ECT) detection of cerebral hemorrhage based on symmetrical cancellation method. Front. Phys., 12.10.3389/fphy.2024.1392767 ↗
3. Graph Convolutional Networks for Enhanced Resolution 3D Electrical Capacitance Tomography Image Reconstruction10.1016/j.asoc.2021.107608 ↗
4. Wang, Z., and Bovik, A.C. (2006). Modern Image Quality Assessment, Morgan & Claypool.10.1007/978-3-031-02238-8 ↗
5. Non-Invasive Process Imaging – Principles and Applications of Industrial Process Tomography10.1002/ceat.200390107 ↗
6. Image reconstruction algorithms for electrical capacitance tomography10.1088/0957-0233/14/1/201 ↗
7. Spatial imaging with 3D capacitance measurements10.1088/0957-0233/17/8/009 ↗
8. Warsito, W., and Fan, L.S. (2003, January 2–5). Development of three-dimensional electrical capacitance tomography. Proceedings of the 3rd World Congress on Industrial Process Tomography, Banff, AB, Canada.
9. Three-dimensional nonlinear inversion of electrical capacitance tomography data using a complete sensor model10.2528/PIER09111201 ↗
10. Nonlinear Image Reconstruction for Electrical Capacitance Tomography Using Experimental Data10.1088/0957-0233/16/10/014 ↗
11. Application of Electrical Capacitance Tomography for Measurement of Gas-Solids Flow Characteristics in a Pneumatic Conveying System10.1088/0957-0233/12/8/317 ↗
12. Majchrowicz, M., Kapusta, P., Jackowska-Strumillo, L., Banasiak, R., and Sankowski, D. (2020). Multi-GPU, Multi-Node Algorithms for Acceleration of Image Reconstruction in 3D Electrical Capacitance Tomography in Heterogeneous Distributed System. Sensors, 20.10.3390/s20020391 ↗
13. Neural networks and stochastic search methods applied to industrial capacitive tomography10.1016/S0967-0661(98)00139-7 ↗
14. A review of statistical modelling and inference for electrical capacitance tomography10.1088/0957-0233/20/5/052002 ↗
15. A novel Gauss-Newton image reconstruction algorithm for Electrical Capacitance Tomography System
16. An Autoencoder Based Image Reconstruction for Electrical Capacitance Tomography10.1109/JSEN.2018.2836337 ↗
17. Deep Learning-Based Inversion Method for Imaging Problems in Electrical Capacitance Tomography10.1109/TIM.2018.2811228 ↗
18. Zheng, J., Ma, H., and Peng, L. (2019, January 9–10). A CNN-Based Image Reconstruction for Electrical Capacitance Tomography. Proceedings of the 2019 IEEE International Conference on Imaging Systems and Techniques (IST), Abu Dhabi, United Arab Emirates.10.1109/IST48021.2019.9010096 ↗
19. ECT Image Reconstruction Algorithm Based on Multiscale Dual-Channel Convolutional Neural Network
20. Electrical capacitance tomography with a non-circular sensor using the dbar method10.1088/0957-0233/21/1/015502 ↗
21. The use of the multi-sequential LSTM in electrical tomography for masonry wall moisture detection10.1016/j.measurement.2024.114860 ↗
22. Kulisz, M., Kłosowski, G., Rymarczyk, T., Słoniec, J., Gauda, K., and Cwynar, W. (2024). Optimizing the Neural Network Loss Function in Electrical Tomography to Increase Energy Efficiency in Industrial Reactors. Energies, 17.10.3390/en17030681 ↗
23. A Novel Image Reconstruction Strategy for ECT: Combining Two Algorithms With a Graph Cut Method10.1109/TIM.2019.2905282 ↗
24. Deabes, W., Abdel-Hakim, A.E., Bouazza, K.E., and Althobaiti, H. (2022). Adversarial Resolution Enhancement for Electrical Capacitance Tomography Image Reconstruction. Sensors, 22.10.3390/s22093142 ↗
25. Electrical Capacitance Volume Tomography: Design and Applications10.3390/s100301890 ↗
26. Image quality assessment: From error visibility to structural similarity10.1109/TIP.2003.819861 ↗