journal article·2024-09-27Open access

Test–Retest Reliability of Concentric and Eccentric Muscle Strength in Knee Flexion–Extension Controlled by Functional Electromechanical Dynamometry in Female Soccer

Oscar Andrades-Ramírez, David Ulloa-Díaz, Angela Rodríguez-Perea, Sergio Araya-Sierralta, Francisco Guede-Rojas, Gustavo Muñoz-Bustos, Luis-Javier Chirosa-Ríos

Applied Sciences· Volume 14· Issue 19

Abstract

In the field of sports performance, sports medicine, and physical rehabilitation, there is a great interest in the development of protocols and reliable techniques and instruments for the evaluation of strength produced by athletes. In the last ten years, women’s football has increased its popularity and participation in numerous countries, which has contributed to players developing more professionally and requiring more specific muscle strength training to improve their performance. The aim of this study was to analyze the absolute and relative test–retest reliabilities of peak muscle strength in knee flexion (FLE) and extension (EXT) controlled using a functional electromechanical dynamometer (FEMD) in a group of seventeen professional female soccer players (age = 18.64 ± 0.62 years; weight = 54.72 ± 7.03 kg; height = 1.58 ± 0.04 m; BMI = 21.62 ± 2.70 kg/m2). Peak muscle strength was measured with knee flexion (FLE) and extension (EXT) movements at a speed of 0.4 m·s−1 unilaterally in a concentric phase (CON) and an eccentric phase (ECC). No significant mean differences were found in the test–retest analysis (p > 0.05; effect size < 0.14), and high reliability was reported for peak muscle strength assessments in both the CON (ICC) = 0.90–0.95) and the ECC (ICC = 0.85–0.97). Furthermore, stable repeatability was presented for extension in the CON (CV = 7.39–9.91%) and ECC (CV = 8.65–13.64). The main findings of this study show that peak muscle strength in knee flexion and extension in CON and ECC is a measure with acceptable absolute reliability and extremely high relative reliability using the FEMD in professional female soccer players.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Sports Performance and Training · Sports injuries and prevention · Lower Extremity Biomechanics and Pathologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, 18011 Granada, Spain

Facultad de Salud y Ciencias Sociales, Escuela de Ciencias de la Actividad Física, Universidad de las Américas, Concepción 4030000, Chile

Department of Sports Sciences and Physical Conditioning, Universidad Católica de la Santísima Concepción, Concepción 4030000, Chile

Strength & Conditioning Laboratory, CTS-642 Research Group, Department of Physical Education and Sports, Faculty of Sport Sciences, University of Granada, 18011 Granada, Spain

Department of Physical and Sport Education, University of León, 24071 León, Spain

Facultad de Humanidades y Educación, Universidad de Atacama, Copiapó 1531772, Chile

Exercise and Rehabilitation Sciences Institute, School of Physical Therapy, Faculty of Rehabilitation Sciences, Universidad Andres Bello, Santiago 7591538, Chile

Facultad de Salud, Escuela de Nutrición y Dietética, Universidad Santo Tomas, Iquique 1100000, Chile

References (40)

Show source-provided references
1. McBride, L., James, R.S., Alsop, S., and Oxford, S.W. (2023). Intra and Inter-Rater Reliability of a Novel Isometric Test of Neck Strength. Sports, 11.10.3390/sports11010002 ↗
2. Venegas-Carro, M., Kramer, A., Moreno-Villanueva, M., and Gruber, M. (2022). Test–Retest Reliability and Sensitivity of Common Strength and Power Tests over a Period of 9 Weeks. Sports, 10.10.3390/sports10110171 ↗
3. The periodization of resistance training in soccer players: Changes in maximal strength, lower extremity power, body composition and muscle volume
4. Effects of High-Velocity Resistance Training on Athletic Performance in Prepuberal Male Soccer Athletes10.1519/JSC.0000000000001433 ↗
5. Transfer of a resistance training program to sprinting and vertical jump in youth soccer players: Squats vs. lunges10.47197/retos.v46.93296 ↗
6. Match Physical Performance of Elite Female Soccer Players during International Competition10.1519/JSC.0000000000001575 ↗
7. Effects of 6 weeks in-season flywheel squat resistance training on strength, vertical jump, change of direction and sprint performance in professional female soccer players10.5114/biolsport.2023.118022 ↗
8. Brígido-Fernández, I., García-Muro San José, F., Charneco-Salguero, G., Cárdenas-Rebollo, J.M., Ortega-Latorre, Y., Carrión-Otero, O., and Fernández-Rosa, L. (2022). Knee Isokinetic Profiles and Reference Values of Professional Female Soccer Players. Sports, 10.10.3390/sports10120204 ↗
9. McFarland, I.T., Dawes, J.J., Elder, C.L., and Lockie, R.G. (2016). Relationship of Two Vertical Jumping Tests to Sprint and Change of Direction Speed among Male and Female Collegiate Soccer Players. Sports, 4.10.3390/sports4010011 ↗
10. Fédération Internationale de Footbal Association (2020, May 01). Women’s Football across the National Associations. Available online: https://www.uefa.com/MultimediaFiles/Download/OfficialDocument/uefaorg/Women%27sfootball/02/43/13/56/2431356_DOWNLOAD.pdf.
11. Physiological Characteristics of Female Soccer Players and Health and Performance Considerations: A Narrative Review10.1007/s40279-021-01458-1 ↗
12. Pardos-Mainer, E., Lozano, D., Torrontegui-Duarte, M., Cartón-Llorente, A., and Roso-Moliner, A. (2021). Effects of Strength vs. Plyometric Training Programs on Vertical Jumping, Linear Sprint and Change of Direction Speed Performance in Female Soccer Players: A Systematic Review and Meta-Analysis. Int. J. Environ. Res. Public Health, 18.10.3390/ijerph18020401 ↗
13. Chirosa-Ríos, L.J., Chirosa-Ríos, I.J., Martínez-Marín, I., Román-Montoya, Y., and Vera-Vera, J.F. (2023). The Role of the Specific Strength Test in Handball Performance: Exploring Differences across Competitive Levels and Age Groups. Sensors, 23.10.3390/s23115178 ↗
14. del-Cuerpo, I., Jerez-Mayorga, D., Delgado-Floody, P., Morenas-Aguilar, M., and Chirosa-Ríos, L. (2023). Test–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise. Int. J. Environ. Res. Public Health, 20.10.3390/ijerph20021289 ↗
15. Behavior of the muscle quality index and isometric strength in elderly women10.1016/j.physbeh.2020.113145 ↗
16. Reliability and concurrent validity of a functional electromechanical dynamometer device for the assessment of movement velocity
17. Vega, E.C., Jerez-Mayorga, D., Payer, R.M., Jara, C.C., Guzman-Guzman, I., Ponce, A.R., and Chirosa, L.J. (2018). Validity and reliability of evaluating hip abductor strength using different normalization methods in a functional electromechanical device. PLoS ONE, 13.10.1371/journal.pone.0202248 ↗
18. Andrades-Ramírez, O., Ulloa-Díaz, D., Alfaro Castillo, B., Arroyo-Jofré, P., Castillo-Paredes, A., and Chirosa-Ríos, L. (2024). Test–Retest Reliability of an Isometric and Isometric/Vibratory Muscular Strength Protocol with Functional Electro-Mechanical Dynamometry. Sports, 12.10.3390/sports12070175 ↗
19. Concurrent validity and reliability of a functional electromechanical dynamometer to assess isometric mid-thigh pull performance
20. Jerez-Mayorga, D., Huerta-Ojeda, A., Chirosa-Ríos, L., Guede-Rojas, F., Guzmán-Guzmán, I., Intelangelo, L., Miranda-Fuentes, C., and Delgado-Floody, P. (2021). Test-Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults. Int. J. Environ. Res. Public Health, 18.10.3390/ijerph18136829 ↗
21. Reliability of a standing isokinetic shoulder rotators strength test using a functional electromechanical dynamometer: Effects of velocity10.7717/peerj.9951 ↗
22. Test-retest reliability of a functional electromechanical dynamometer on swing eccentric hamstring exercise measures in soccer players10.7717/peerj.11743 ↗
23. World Medical Association (2013). World Medical Association Declaration of Helsinki: Ethical principles for medical research involving human subjects. JAMA, 310, 2191–2194.10.1001/jama.2013.281053 ↗
24. Spreadsheets for analysis of validity and reliability
25. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM
26. A review of the reliability of biomechanical variables produced during the isometric mid-thigh pull and isometric squat and the reporting of normative data10.1080/14763141.2018.1452968 ↗
27. Validity and test-retest reliability of the 1080 quantum system for bench press exercise10.1519/JSC.0000000000003184 ↗
28. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine10.2165/00007256-199826040-00002 ↗
29. Progressive statistics for studies in sports medicine and exercise science10.1249/MSS.0b013e31818cb278 ↗
30. Test-retest reliability of isokinetic concentric knee extension and flexion10.1136/bjsm.2010.078972.80 ↗
31. Reliability of knee extension and flexion measurements using the Con-Trex isokinetic dynamometer10.1111/j.1475-097X.2007.00758.x ↗
32. Multiple-Joint Isokinetic Dynamometry: A Critical Review10.1519/JSC.0000000000002982 ↗
33. Reliability of isometric and isokinetic trunk flexor strength using a functional electromechanical dynamometer10.7717/peerj.7883 ↗
34. Reyes-Ferrada, W., Rodríguez-Perea, Á., Chirosa-Ríos, L., Martínez-García, D., and Jerez-Mayorga, D. (2022). Muscle Quality and Functional and Conventional Ratios of Trunk Strength in Young Healthy Subjects: A Pilot Study. Int. J. Environ. Res. Public Health, 19.10.3390/ijerph191912673 ↗
35. Rodríguez-Perea, A., Jerez-Mayorga, D., Morenas-Aguilar, M., Martínez-García, D., Chirosa-Ríos, I., Chirosa-Ríos, L., and Reyes-Ferrada, W. (2023). Influence of Sex and Dominant Side on the Reliability of Two Trunk Rotator Exercises. Appl. Sci., 13.10.3390/app13042441 ↗
36. García-Buendía, G., Rodríguez-Perea, Á., Chirosa-Ríos, I., Chirosa-Ríos, L.J., and Martínez-García, D. (2024). Reliability of Dynamic Shoulder Strength Test Battery Using Multi-Joint Isokinetic Device. Sensors, 24.10.3390/s24113568 ↗
37. Reproducibility of shoulder short range of motion isokinetic and in isometric strength testing10.1016/j.jesf.2012.10.005 ↗
38. Isokinetic dynamometry applied to shoulder rotators–Velocity limitations in eccentric evaluations10.1016/j.jsams.2011.05.002 ↗
39. The effect of velocity and familiarization on the reproducibility of isokinetic dynamometry10.3233/IES-150582 ↗
40. Predictive Value of Technical Throwing Skills on Nomination Status in Youth and Long-Term Career Attainment in Handball10.1186/s40798-021-00397-5 ↗