journal article·2024-08-30Open access

The Essential Role of Monte Carlo Simulations for Lung Dosimetry in Liver Radioembolization with 90Y Microspheres

Edoardo d’Andrea, Nico Lanconelli, Marta Cremonesi, Vincenzo Patera, Massimiliano Pacilio

Applied Sciences· Volume 14· Issue 17

Abstract

This study compares various methodologies for lung dosimetry in radioembolization using Monte Carlo (MC) simulations. A voxelized anthropomorphic phantom, created from a real patient’s CT scan, preserved the actual density distribution of the lungs. Lung dosimetry was evaluated for five lung-shunt (LS) cases using traditional methods: the mono-compartmental organ-level approach (MIRD), local energy deposition (LED), and convolution with voxel S-values, either with local density corrections (SVOX_L) or without (SVOX_ST). Additionally, a novel voxel S-value (VSV) kernel for lung tissue with an ICRU density of 0.296 g/cm3 was developed. Calculations were performed using either the ICRU lung density (Lung_296), the average lung density of the phantom (Lung_221), or the local density (Lung_L). The comparison revealed significant underestimations in the mean absorbed dose (AD) for the classical approaches: approximately −40% for MIRD, −27% for LED, −28% for SVOX_L, and −88% for SVOX_ST. Similarly, calculations with the lung VSV kernel showed underestimations of about −62% for Lung_296, −50% for Lung_221, and −35% for Lung_L. Given the high heterogeneity of lung tissue, traditional dosimetric methods fail to provide accurate estimates of the mean AD for the lungs. Therefore, MC dosimetry based on patient images is recommended as the preferred method for precise assessment of lung AD during radioembolization.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Radiotherapy Techniques · Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Postgraduate School of Medical Physics, Azienda Ospedaliero-Universitaria Policlinico Umberto I, 00161 Rome, Italy

Department of Medical Physics, Azienda Ospedaliero-Universitaria Policlinico Umberto I, 00161 Rome, Italy

Department of Physics and Astronomy, Università di Bologna, 40126 Bologna, Italy

Medical Physics Unit, IEO, European Institute of Oncology IRCCS, 20141 Milan, Italy

Department of Basic and Applied Science for Engineering, University of Roma “Sapienza”, 00161 Rome, Italy

Sezione di Roma I, Istituto Nazionale di Fisica Nucleare, 00161 Rome, Italy

References (42)

Show source-provided references
1. Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries10.3322/caac.21492 ↗
2. Recommendations of the American Association of Physicists in Medicine on dosimetry, imaging, and quality assurance procedures for 90Y microsphere brachytherapy in the treatment of hepatic malignancies10.1118/1.3608909 ↗
3. EANM procedure guideline for the treatment of liver cancer and liver metastases with intra-arterial radioactive compounds10.1007/s00259-021-05600-z ↗
4. (2024, August 13). Sirtex: SIR-Spheres® Microspheres. Available online: https://www.sirtex.com/ap/products/sir-spheres-y-90-resin-microspheres/about-sir-spheres/approved-indication/.
5. (2024, August 13). BTG: TheraSphere® Yttrium-90 Glass Microspheres, Available online: https://www.nrc.gov/docs/ML1427/ML14279A535.pdf.
6. International recommendations for personalised selective internal radiation therapy of primary and metastatic liver diseases with yttrium-90 resin microspheres10.1007/s00259-020-05163-5 ↗
7. Clinical, dosimetric, and reporting considerations for Y-90 glass microspheres in hepatocellular carcinoma: Updated 2022 recommendations from an international multidisciplinary working group10.1007/s00259-022-05956-w ↗
8. To 1000 Gy and back again: A systematic review on dose-response evaluation in selective internal radiation therapy for primary and secondary liver cancer10.1007/s00259-021-05340-0 ↗
9. The use of neoadjuvant lobar radioembolization prior to major hepatic resection for malignancy results in a low rate of post hepatectomy liver failure10.21037/jgo-20-507 ↗
10. Yttrium-90 radioembolization as a bridge to liver transplantation: A single-institution experience10.1016/j.jvir.2013.07.026 ↗
11. Kim, H.C., and Kim, G.M. (2023). Radiation pneumonitis following Yttrium-90 radioembolization: A Korean multicenter study. Front. Oncol., 13.10.3389/fonc.2023.977160 ↗
12. Milano, A., Gil, A.V., Fabrizi, E., Cremonesi, M., Veronese, I., Gallo, S., and Pacilio, M. (2021). In Silico Validation of MCID Platform for Monte Carlo-Based Voxel Dosimetry Applied to 90Y-Radioembolization of Liver Malignancies. Appl. Sci., 11.10.3390/app11041939 ↗
13. Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for (90)Y microsphere selective internal radiation therapy
14. Capotosti, A., Moretti, R., Vaccaro, M., Ribeiro, C.D.A., Placidi, L., Nardini, M., Meffe, G., Cusumano, D., Zagaria, L., and De Risi, M. (2024). The Role of Lung Density in the Voxel-Based Dosimetry of 90Y-TARE Evaluated with the Voxel S-Value (VSV) Method and Fast Monte Carlo Simulation. Appl. Sci., 14.10.3390/app14031019 ↗
15. Study of the impact of tissue density heterogeneities on 3-dimensional abdominal dosimetry: Comparison between dose kernel convolution and direct Monte Carlo methods10.2967/jnumed.112.105825 ↗
16. Lung dosimetry for radioiodine treatment planning in the case of diffuse lung metastases
17. Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation
18. User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability10.1016/j.neuroimage.2006.01.015 ↗
19. 3D Slicer as an image computing platform for the Quantitative Imaging Network10.1016/j.mri.2012.05.001 ↗
20. Meijering, E.H.W., Niessen, W.J., Pluim, J.P., and Viergever, M.A. (1999, January 19–22). Quantitative Comparison of Sinc-Approximating Kernels for Medical Image Interpolation. International Conference on Medical Image Computing and Computer-Assisted Intervention. Proceedings of the Medical Image Computing and Computer-Assisted Intervention–MICCAI’99: Second International Conference, Cambridge, UK.10.1007/10704282_23 ↗
21. ICRU (1989). Tissue Substitutes in Radiation Dosimetry and Measurement, International Commission on Radiation Units and Measurements. ICRU Report No 44.
22. ICRU (1992). Photon, Electron, Proton, and Neutron Interaction Data for Bodytissues, International Commission on Radiation Units and Measurements. ICRU Report No 46.
23. EANM dosimetry committee series on standard operational procedures: A unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres
24. MIRD Pamphlet No. 21: A Generalized Schema for Radiopharmaceutical Dosimetry—Standardization of Nomenclature10.2967/jnumed.108.056036 ↗
25. MIRD pamphlet No. 17: The dosimetry of nonuniform activity distributions--radionuclide S values at the voxel level. Medical Internal Radiation Dose Committee
26. A free database of radionuclide voxel S values for the dosimetry of nonuniform activity distributions10.1088/0031-9155/57/2/517 ↗
27. Differences in 3D dose distributions due to calculation method of voxel S-values and the influence of image blurring in SPECT10.1088/0031-9155/60/5/1945 ↗
28. Lung density as measured by computerized tomography: Implications for radiotherapy10.1016/0360-3016(82)90587-9 ↗
29. Jan, S., Santin, G., Strul, D., Staelens, S., Assié, K., Autret, D., and Morel, C. (2004). GATE: A simulation toolkit for PET and SPECT. Phys. Med. Biol., 49.10.1088/0031-9155/49/19/007 ↗
30. Reporting and analyzing statistical uncertainties in Monte Carlo-based treatment planning10.1016/j.ijrobp.2006.03.039 ↗
31. Berger, M., Coursey, J., and Zucker, M. (2024, August 13). ESTAR, PSTAR, and ASTAR: Computer Programs for Calculating Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions (Version 1.21), Available online: http://physics.nist.gov/Star.
32. Chen, G., Lu, Z., Jiang, H., Lin, K.H., and Mok, G.S. (2023). Voxel-S-Value based 3D treatment planning methods for Y-90 microspheres radioembolization based on Tc-99m-macroaggregated albumin SPECT/CT. Sci. Rep., 13.10.1038/s41598-023-30824-4 ↗
33. Using an Assumed Lung Mass Inaccurately Estimates the Lung Absorbed Dose in Patients Undergoing Hepatic 90Yttrium Radioembolization Therapy10.1007/s00270-022-03197-w ↗
34. Reassessment of the lung dose limits for radioembolization10.1097/MNM.0000000000001439 ↗
35. Auditore, L., Amato, E., Boughdad, S., Meyer, M., Testart, N., Cicone, F., and Gnesin, S. (2020). Monte Carlo 90Y PET/CT dosimetry of unexpected focal radiation-induced lung damage after hepatic radioembolisation. Phys. Med. Biol., 65.10.1088/1361-6560/abbc80 ↗
36. A deep-learning-based prediction model for the biodistribution of 90Y microspheres in liver radioembolization10.1002/mp.15270 ↗
37. Contemporary applications of Y90 for the treatment of hepatocellular carcinoma10.1097/HC9.0000000000000288 ↗
38. Fred: A GPU-accelerated fast-Monte Carlo code for rapid treatment plan recalculation in ion beam therapy10.1088/1361-6560/aa8134 ↗
39. GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications10.1088/0031-9155/60/13/4987 ↗
40. 90Y post-radioembolization clinical assessment with whole-body Biograph Vision Quadra PET/CT: Image quality, tumor, liver and lung dosimetry10.1007/s00259-024-06650-9 ↗
41. Lee, M.S., Hwang, D., Kim, J.H., and Lee, J.S. (2019). Deep-dose: A voxel dose estimation method using deep convolutional neural network for personalized internal dosimetry. Sci. Rep., 9.10.1038/s41598-019-46620-y ↗
42. DblurDoseNet: A deep residual learning network for voxel radionuclide dosimetry compensating for single-photon emission computerized tomography imaging resolution10.1002/mp.15397 ↗