journal article·2024-05-28Open access

CycleGAN-Driven MR-Based Pseudo-CT Synthesis for Knee Imaging Studies

Daniel Vallejo-Cendrero, Juan Manuel Molina-Maza, Blanca Rodriguez-Gonzalez, David Viar-Hernandez, Borja Rodriguez-Vila, Javier Soto-Pérez-Olivares, Jaime Moujir-López, Carlos Suevos-Ballesteros, Javier Blázquez-Sánchez, José Acosta-Batlle, Angel Torrado-Carvajal

Applied Sciences· Volume 14· Issue 11

Abstract

In the field of knee imaging, the incorporation of MR-based pseudo-CT synthesis holds the potential to mitigate the need for separate CT scans, simplifying workflows, enhancing patient comfort, and reducing radiation exposure. In this work, we present a novel DL framework, grounded in the development of the Cycle-Consistent Generative Adversarial Network (CycleGAN) method, tailored specifically for the synthesis of pseudo-CT images in knee imaging to surmount the limitations of current methods. Upon visually examining the outcomes, it is evident that the synthesized pseudo-CTs show an excellent quality and high robustness. Despite the limited dataset employed, the method is able to capture the particularities of the bone contours in the resulting image. The experimental Mean Absolute Error (MAE), Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), Zero-Normalized Cross Correlation (ZNCC), Mutual Information (MI), Relative Change (RC), and absolute Relative Change (|RC|) report values of 30.4638 ± 7.4770, 28.1168 ± 1.5245, 0.9230 ± 0.0217, 0.9807 ± 0.0071, 0.8548 ± 0.1019, 0.0055 ± 0.0265, and 0.0302 ± 0.0218 (median ± median absolute deviation), respectively. The voxel-by-voxel correlation plot shows an excellent correlation between pseudo-CT and ground-truth CT Hounsfield units (m = 0.9785; adjusted R2 = 0.9988; ρ = 0.9849; p < 0.001). The Bland–Altman plot shows that the average of the differences is low ((HUCT−HUpseudo−CT = 0.7199 ± 35.2490; 95% confidence interval [−68.3681, 69.8079]). This study represents the first reported effort in the field of MR-based knee pseudo-CT synthesis, shedding light to significantly advance the field of knee imaging.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Generative Adversarial Networks and Image Synthesis · Radiomics and Machine Learning in Medical Imaging · Cell Image Analysis Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Medical Image Analysis and Biometry Laboratory, Universidad Rey Juan Carlos, 28933 Móstoles, Spain

Department of Radiology, Hospital Universitario Ramón y Cajal, IRYCIS, 28034 Madrid, Spain

Funding

Fundación para la Investigación Biomédica del Hospital Universitario Ramón y Cajal · Ministerio de Ciencia e Investigación (MCIN)/Agencia Estatal de Investigación (AEI)

References (34)

Show source-provided references
1. Davies, M., James, S., and Botchu, R. (2023). Imaging of the Knee: Techniques and Applications, Springer.10.1007/978-3-031-29731-1 ↗
2. 3D MRI in musculoskeletal imaging: Current and future applications10.1007/s40134-018-0287-3 ↗
3. MRI Advancements in Musculoskeletal Clinical and Research Practice10.1148/radiol.230531 ↗
4. Computed tomography: State-of-the-art advancements in musculoskeletal imaging10.1097/RLI.0000000000000908 ↗
5. Musculoskeletal CT Imaging: State-of-the-Art Advancements and Future Directions10.1148/radiol.230344 ↗
6. Emerging technology in musculoskeletal MRI and CT10.1148/radiol.220634 ↗
7. Positron emission tomography with 18F-FDG in osteoarthritic knee10.1016/j.joca.2006.12.010 ↗
8. PET/computed tomography shows association between subjective pain in knee joints and fluorine-18-fluorodeoxyglucose uptake10.1097/MNM.0000000000001143 ↗
9. [11C]-PBR28 Positron Emission Tomography Signal as an Imaging Marker of Joint Inflammation in Knee Osteoarthritis10.1097/j.pain.0000000000003114 ↗
10. Long-term efficacy of low-dose radiation therapy on symptoms in patients with knee and hand osteoarthritis: Follow-up results of two parallel randomised, sham-controlled trials10.1016/S2665-9913(19)30096-7 ↗
11. Low-dose RaDiation therapy for patients with KNee osteoArthritis (LoRD-KNeA): A protocol for a sham-controlled randomised trial10.1136/bmjopen-2022-069691 ↗
12. Chong, L., Lee, K., and Sim, F. (2021). 3D MRI with CT-like bone contrast—An overview of current approaches and practical clinical implementation. Eur. J. Radiol., 143.10.1016/j.ejrad.2021.109915 ↗
13. Magnetic Resonance Imaging Versus Computed Tomography for Three-Dimensional Bone Imaging of Musculoskeletal Pathologies: A Review10.1002/jmri.28067 ↗
14. VIBE MRI: An alternative to CT in the imaging of sports-related osseous pathology?10.1259/bjr.20170815 ↗
15. Zero Echo Time Musculoskeletal MRI: Technique, Optimization, Applications, and Pitfalls10.1148/rg.220029 ↗
16. Synthetic CT in Musculoskeletal Disorders: A Systematic Review10.1097/RLI.0000000000000916 ↗
17. Pseudo-CT generation in brain MR-PET attenuation correction: Comparison of several multi-atlas methods10.1186/2197-7364-2-S1-A29 ↗
18. A multi-centre evaluation of eleven clinically feasible brain PET/MRI attenuation correction techniques using a large cohort of patients10.1016/j.neuroimage.2016.12.010 ↗
19. Magnetic resonance-based attenuation correction and scatter correction in neurological positron emission tomography/magnetic resonance imaging—Current status with emerging applications10.3389/fphy.2019.00243 ↗
20. Deep learning based synthetic-CT generation in radiotherapy and PET: A review10.1002/mp.15150 ↗
21. Deep learning methods to generate synthetic CT from MRI in radiotherapy: A literature review10.1016/j.ejmp.2021.07.027 ↗
22. Vera-Olmos, J., Torrado-Carvajal, A., Prieto-de-la Lastra, C., Catalano, O.A., Rozenholc, Y., Mazzeo, F., Soricelli, A., Salvatore, M., Izquierdo-Garcia, D., and Malpica, N. (2022). How to Pseudo-CT: A Comparative Review of Deep Convolutional Neural Network Architectures for CT Synthesis. Appl. Sci., 12.10.3390/app122211600 ↗
23. Martinez-Girones, P.M., Vera-Olmos, J., Gil-Correa, M., Ramos, A., Garcia-Ca namaque, L., Izquierdo-Garcia, D., Malpica, N., and Torrado-Carvajal, A. (2021). Franken-CT: Head and neck mr-based pseudo-CT synthesis using diverse anatomical overlapping MR–CT scans. Appl. Sci., 11.10.3390/app11083508 ↗
24. Dixon-VIBE deep learning (DIVIDE) pseudo-CT synthesis for pelvis PET/MR attenuation correction10.2967/jnumed.118.209288 ↗
25. Evaluation of Deep Learning–Based Approaches to Segment Bowel Air Pockets and Generate Pelvic Attenuation Maps from CAIPIRINHA-Accelerated Dixon MR Images10.2967/jnumed.120.261032 ↗
26. Augmented deep learning model for improved quantitative accuracy of MR-based PET attenuation correction in PSMA PET-MRI prostate imaging10.1007/s00259-020-04816-9 ↗
27. MRI-only radiotherapy planning for nasopharyngeal carcinoma using deep learning10.3389/fonc.2021.713617 ↗
28. Jabbarpour, A., Mahdavi, S.R., Sadr, A.V., Esmaili, G., Shiri, I., and Zaidi, H. (2022). Unsupervised pseudo CT generation using heterogenous multicentric CT/MR images and CycleGAN: Dosimetric assessment for 3D conformal radiotherapy. Comput. Biol. Med., 143.10.1016/j.compbiomed.2022.105277 ↗
29. Pseudo-CT generation for MRI-only radiation therapy treatment planning: Comparison among patch-based, atlas-based, and bulk density methods10.1016/j.ijrobp.2018.10.002 ↗
30. Comparison of deep learning-based and patch-based methods for pseudo-CT generation in MRI-based prostate dose planning10.1016/j.ijrobp.2019.08.049 ↗
31. Zhu, J.Y., Park, T., Isola, P., and Efros, A.A. (2017, January 22–29). Unpaired image-to-image translation using cycle-consistent adversarial networks. Proceedings of the IEEE International Conference on Computer Vision, Venice, Italy.10.1109/ICCV.2017.244 ↗
32. Dc-cyclegan: Bidirectional ct-to-mr synthesis from unpaired data10.1016/j.compmedimag.2023.102249 ↗
33. Kikinis, R., Pieper, S.D., and Vosburgh, K.G. (2013). Intraoperative Imaging and Image-Guided Therapy, Springer.
34. Elastix: A toolbox for intensity-based medical image registration10.1109/TMI.2009.2035616 ↗