journal article·2024-03-14Open access

Estimation of Systolic and Diastolic Blood Pressure for Hypertension Identification from Photoplethysmography Signals

Hygo Sousa De Oliveira, Rafael Albuquerque Pinto, Eduardo James Pereira Souto, Rafael Giusti

Applied Sciences· Volume 14· Issue 6

Abstract

Continuous monitoring plays a crucial role in diagnosing hypertension, characterized by the increase in Arterial Blood Pressure (ABP). The gold-standard method for obtaining ABP involves the uncomfortable and invasive technique of cannulation. Conversely, ABP can be acquired non-invasively by using Photoplethysmography (PPG). This non-invasive approach offers the advantage of continuous BP monitoring outside a hospital setting and can be implemented in cost-effective wearable devices. PPG and ABP signals differ in scale values, which creates a non-linear relationship, opening avenues for the utilization of algorithms capable of detecting non-linear associations. In this study, we introduce Neural Model of Blood Pressure (NeuBP), which estimates systolic and diastolic values from PPG signals. The problem is treated as a binary classification task, distinguishing between Normotensive and Hypertensive categories. Furthermore, our research investigates NeuBP’s performance in classifying different BP categories, including Normotensive, Prehypertensive, Grade 1 Hypertensive, and Grade 2 Hypertensive cases. We evaluate our proposed method by using data from the publicly available MIMIC-III database. The experimental results demonstrate that NeuBP achieves results comparable to more complex models with fewer parameters. The mean absolute errors for systolic and diastolic values are 5.02 mmHg and 3.11 mmHg, respectively.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Heart Rate Variability and Autonomic Control · Hemodynamic Monitoring and Therapy

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Computing, Federal University of Amazonas, Manaus 69077-000, AM, Brazil

Funding

Samsung Electronics of Amazonia Ltda · Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil (CAPES) · Amazonas State Research Support Foundation—FAPEAM

References (38)

Show source-provided references
1. World Health Organization cardiovascular disease risk charts: Revised models to estimate risk in 21 global regions10.1016/S2214-109X(19)30318-3 ↗
2. Athaya, T., and Choi, S. (2021). An Estimation Method of Continuous Non-Invasive Arterial Blood Pressure Waveform Using Photoplethysmography: A U-Net Architecture-Based Approach. Sensors, 21.10.3390/s21051867 ↗
3. 2020 International Society of Hypertension global hypertension practice guidelines10.1161/HYPERTENSIONAHA.120.15026 ↗
4. An optimal filter for short photoplethysmogram signals10.1038/sdata.2018.76 ↗
5. Hypertension—A Silent Killer Without Global Bounds: What Next10.1016/j.jacc.2022.05.043 ↗
6. 2021 World Health Organization guideline on pharmacological treatment of hypertension: Policy implications for the region of the Americas
7. The use of photoplethysmography for assessing hypertension10.1038/s41746-019-0136-7 ↗
8. Complications of invasive monitoring10.1016/S0889-8537(02)00004-4 ↗
9. Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients10.1097/01.CCM.0000053650.12025.1A ↗
10. Principles and techniques of blood pressure measurement10.1016/j.ccl.2010.07.006 ↗
11. Zhang, X., Wang, C., Zheng, T., Wu, H., Wu, Q., and Wang, Y. (2023). Wearable optical fiber sensors in medical monitoring applications: A review. Sensors, 23.10.3390/s23156671 ↗
12. Chu, Y., Tang, K., Hsu, Y.C., Huang, T., Wang, D., Li, W., Savitz, S.I., Jiang, X., and Shams, S. (2023). Non-invasive arterial blood pressure measurement and SpO2 estimation using PPG signal: A deep learning framework. BMC Med. Inform. Decis. Mak., 23.10.1186/s12911-023-02215-2 ↗
13. Jeyhani, V., Mahdiani, S., Peltokangas, M., and Vehkaoja, A. (2015, January 25–29). Comparison of HRV parameters derived from photoplethysmography and electrocardiography signals. Proceedings of the 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy.10.1109/EMBC.2015.7319747 ↗
14. Cardiologist-level arrhythmia detection and classification in ambulatory electrocardiograms using a deep neural network10.1038/s41591-018-0268-3 ↗
15. Rundo, F., Conoci, S., Ortis, A., and Battiato, S. (2018). An advanced bio-inspired photoplethysmography (PPG) and ECG pattern recognition system for medical assessment. Sensors, 18.10.3390/s18020405 ↗
16. Pervasive blood pressure monitoring using Photoplethysmogram (PPG) sensor10.1016/j.future.2019.02.032 ↗
17. Wearables and the Internet of Things (IoT), applications, opportunities, and challenges: A Survey10.1109/ACCESS.2020.2986329 ↗
18. Liang, Y., Chen, Z., Ward, R., and Elgendi, M. (2018). Hypertension assessment via ECG and PPG signals: An evaluation using MIMIC database. Diagnostics, 8.10.3390/diagnostics8030065 ↗
19. Slapničar, G., Mlakar, N., and Luštrek, M. (2019). Blood pressure estimation from photoplethysmogram using a spectro-temporal deep neural network. Sensors, 19.10.3390/s19153420 ↗
20. A review of methods for non-invasive and continuous blood pressure monitoring: Pulse transit time method is promising?10.1016/j.irbm.2014.07.002 ↗
21. Nabeel, P., Joseph, J., Awasthi, V., and Sivaprakasam, M. (2016, January 16–20). Single source photoplethysmograph transducer for local pulse wave velocity measurement. Proceedings of the 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA.10.1109/EMBC.2016.7591667 ↗
22. Cuffless blood pressure estimation algorithms for continuous health-care monitoring10.1109/TBME.2016.2580904 ↗
23. Su, P., Ding, X.R., Zhang, Y.T., Liu, J., Miao, F., and Zhao, N. (2018, January 4–7). Long-term blood pressure prediction with deep recurrent neural networks. Proceedings of the 2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI), Las Vegas, NV, USA.10.1109/BHI.2018.8333434 ↗
24. Schlesinger, O., Vigderhouse, N., Eytan, D., and Moshe, Y. (2020, January 4–8). Blood pressure estimation from PPG signals using convolutional neural networks and Siamese network. Proceedings of the ICASSP IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), Barcelona, Spain.10.1109/ICASSP40776.2020.9053446 ↗
25. Zhang, Y., and Feng, Z. (2017, January 24–26). A SVM method for continuous blood pressure estimation from a PPG signal. Proceedings of the 9th International Conference on Machine Learning and Computing, Singapore.10.1145/3055635.3056634 ↗
26. Xie, Q., Wang, G., Peng, Z., and Lian, Y. (2018, January 19–21). Machine learning methods for real-time blood pressure measurement based on photoplethysmography. Proceedings of the 2018 IEEE 23rd International Conference on Digital Signal Processing (DSP), Shanghai, China.10.1109/ICDSP.2018.8631690 ↗
27. University of Queensland vital signs dataset: Development of an accessible repository of anesthesia patient monitoring data for research10.1213/ANE.0b013e318241f7c0 ↗
28. Kurylyak, Y., Lamonaca, F., and Grimaldi, D. (2013, January 6–9). A Neural Network-based method for continuous blood pressure estimation from a PPG signal. Proceedings of the 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Minneapolis, MN, USA.10.1109/I2MTC.2013.6555424 ↗
29. MIMIC-III, a freely accessible critical care database10.1038/sdata.2016.35 ↗
30. Liang, Y., Chen, Z., Ward, R., and Elgendi, M. (2018). Photoplethysmography and deep learning: Enhancing hypertension risk stratification. Biosensors, 8.10.3390/bios8040101 ↗
31. Continuous blood pressure estimation from PPG signal
32. Harfiya, L.N., Chang, C.C., and Li, Y.H. (2021). Continuous blood pressure estimation using exclusively photopletysmography by LSTM-based signal-to-signal translation. Sensors, 21.10.3390/s21092952 ↗
33. Qin, K., Huang, W., and Zhang, T. (2021). Deep generative model with domain adversarial training for predicting arterial blood pressure waveform from photoplethysmogram signal. Biomed. Signal Process. Control, 70.10.1016/j.bspc.2021.102972 ↗
34. Ibtehaz, N., Mahmud, S., Chowdhury, M.E., Khandakar, A., Salman Khan, M., Ayari, M.A., Tahir, A.M., and Rahman, M.S. (2022). PPG2ABP: Translating photoplethysmogram (PPG) signals to arterial blood pressure (ABP) waveforms. Bioengineering, 9.10.3390/bioengineering9110692 ↗
35. Rekabdar, B., and Mousas, C. (2018, January 4–7). Dilated convolutional neural network for predicting driver’s activity. Proceedings of the 2018 21st International Conference on Intelligent Transportation Systems (ITSC), Maui, HI, USA.10.1109/ITSC.2018.8569818 ↗
36. Forsyth, D.A., Mundy, J.L., di Gesú, V., Cipolla, R., LeCun, Y., Haffner, P., Bottou, L., and Bengio, Y. (1999). Shape, Contour and Grouping in Computer Vision, Springer.10.1007/3-540-46805-6 ↗
37. O’Shea, K., and Nash, R. (2015). An introduction to convolutional neural networks. arXiv.
38. Oord, A.V.D., Dieleman, S., Zen, H., Simonyan, K., Vinyals, O., Graves, A., Kalchbrenner, N., Senior, A., and Kavukcuoglu, K. (2016). Wavenet: A generative model for raw audio. arXiv.