journal article·2024-01-25Open access

The Role of Lung Density in the Voxel-Based Dosimetry of 90Y-TARE Evaluated with the Voxel S-Value (VSV) Method and Fast Monte Carlo Simulation

Amedeo Capotosti, Roberto Moretti, Maria Vaccaro, Cintia De Almeida Ribeiro, Lorenzo Placidi, Matteo Nardini, Guenda Meffe, Davide Cusumano, Luca Zagaria, Marina De Risi, Germano Perotti, Lucia Leccisotti, Marco De Spirito, Roberto Iezzi, Luca Indovina

Applied Sciences· Volume 14· Issue 3

Abstract

(1) Background: In 90Y-TARE treatments, lung-absorbed doses should be calculated according to the manufacturer’s instructions, using the MIRD-scheme. This scheme is derived from the assumption that 90Y-microspheres deliver the dose in a water-equivalent medium. Since the density of the lungs is quite different from that of the liver, the absorbed dose to the lungs could vary considerably, especially at the liver/lungs interface. The aim of this work is to compare the dosimetric results obtained by two dedicated software packages implementing a water-equivalent dose calculation and a Monte Carlo (MC) simulation, respectively. (2) Methods: An anthropomorphic IEC phantom and a retrospective selection of 24 patients with a diagnosis of HCC were taken into account. In the phantom study, starting from a 90Y-PET/CT acquisition, the liver cavity was manually fixed with a uniform activity concentration on PET series, while the lung compartment was manually expanded on a CT series to simulate a realistic situation in which the liver and lungs are adjacent. These steps were performed by using MIM 90Y SurePlan. Then, a first simulation was carried out with only the liver cavity filled, while a second one was carried out, in which the lung compartment was also manually fixed with a uniform activity concentration corresponding to 10% lung shunt fraction. MIM 90Y SurePlan was used to obtain Voxel S-Value (VSV) approach dose values; instead, Torch was used to obtain MC approach dose values for both the phantom and the patients. (3) Results: In the phantom study, the percentage mean dose differences (∆D%) between VSV and MC in the first and second simulation, respectively were found to be 1.2 and 0.5% (absolute dose variation, ∆D, of 0.7 and 0.3 Gy) for the liver, −56 and 70% (∆D of −0.3 and −16.2 Gy) for the lungs, and −48 and −60% (∆D of −4.3 and −16.5 Gy) for the Liver/Lungs Edge region. The patient study reports similar results with ∆D% between VSV and MC of 7.0%, 4.1% and 6.7% for the whole liver, healthy liver, and tumor, respectively, while the result was −61.2% for the left lung and −61.1% for both the right lung and lungs. (4) Conclusion: Both VSV and MC allowed accurate radiation dose estimation with small differences (<7%) in regions of uniform water-equivalent density (i.e., within the liver). Larger differences between the two methods (>50%) were observed for air-equivalent regions in the phantom simulation and the patient study.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Radiotherapy Techniques · Radiation Therapy and Dosimetry · Medical Imaging Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy

Dipartimento di Ingegneria dell’Informazione, Università di Padova, 35122 Padova, Italy

Dipartimento di Neuroscienze, Università Cattolica del Sacro Cuore, 00168 Rome, Italy

References (40)

Show source-provided references
1. Yttrium-90 Radioembolization: Current Indications and Outcomes10.1007/s11605-022-05559-8 ↗
2. Transcatheter Intraarterial Therapies: Rationale and Overview10.1148/radiol.11081489 ↗
3. Bradford, R., and McKinney, J.M. (2017). Handbook of Radioembolization: Physics, Biology, Nuclear Medicine, and Imaging, CRC Press.
4. Yttrium-90 Microsphere Therapy for Hepatic Malignancy: Devices, Indications, Technical Considerations, and Potential Complications10.1148/rg.25si055515 ↗
5. Recommendations for radioembolization of hepatic malignancies using Yttrium-90 microsphere brachytherapy: A consensus panel report from the Radioembolization Brachytherapy Oncology Consortium (REBOC)10.1016/j.brachy.2007.02.130 ↗
6. Recommendations of the American Association of Physicists in Medicine on dosimetry, imaging, and quality assurance procedures for 90Y microsphere brachytherapy in the treatment of hepatic malignancies: AAPM recommendations 90Y microsphere brachytherapy10.1118/1.3608909 ↗
7. Radiation pneumonitis after selective internal radiation treatment with intraarterial 90Yttrium-microspheres for inoperable hepatic tumors10.1016/0360-3016(95)00039-3 ↗
8. Correlation of dosimetric factors and radiation pneumonitis for non–small-cell lung cancer patients in a recently completed dose escalation study10.1016/j.ijrobp.2005.03.026 ↗
9. Dosimetric Techniques in 90Y-Microsphere Therapy of Liver Cancer: The MIRD Equations for Dose Calculations
10. The MIRD schema: From organ to cellular dimensions
11. A Comparison of Techniques for 90Y PET/CT Image-Based Dosimetry Following Radioembolization with Resin Microspheres10.3389/fonc.2014.00121 ↗
12. A dosimetric treatment planning strategy in radioembolization of hepatocarcinoma with 90Y glass microspheres
13. Dose point kernels for 2174 radionuclides10.1002/mp.13789 ↗
14. Scientific Developments in Imaging and Dosimetry for Molecular Radiotherapy10.1016/j.clon.2020.11.005 ↗
15. Development of a voxel S-value database for patient internal radiation dosimetry10.1016/j.ejmp.2022.102519 ↗
16. Voxel-S-value methods adapted to heterogeneous media for quantitative Y-90 microsphere radioembolization dosimetry10.1016/j.zemedi.2022.11.003 ↗
17. Development of a dose estimation code for BNCT with GPU accelerated Monte Carlo and collapsed cone Convolution method10.1016/j.net.2021.11.010 ↗
18. Development of a collapsed cone convolution/superposition dose calculation algorithm with a mass density-specific water kernel for magnetic resonance-guided radiotherapy10.1093/jrr/rrad011 ↗
19. Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for 90Y microsphere selective internal radiation therapy10.1186/s40658-015-0119-y ↗
20. Study of the Impact of Tissue Density Heterogeneities on 3-Dimensional Abdominal Dosimetry: Comparison Between Dose Kernel Convolution and Direct Monte Carlo Methods10.2967/jnumed.112.105825 ↗
21. Fifty years of Monte Carlo simulations for medical physics10.1088/0031-9155/51/13/R17 ↗
22. A general-purpose Monte Carlo particle transport code based on inverse transform sampling for radiotherapy dose calculation10.1038/s41598-020-66844-7 ↗
23. Fast Monte Carlo simulation for patient-specific CT/CBCT imaging dose calculation10.1088/0031-9155/57/3/577 ↗
24. Fred: A GPU-accelerated fast-Monte Carlo code for rapid treatment plan recalculation in ion beam therapy10.1088/1361-6560/aa8134 ↗
25. Li, Y., Sun, W., Liu, H., Ding, S., Wang, B., Huang, X., and Song, T. (2022). Development of a GPU-superposition Monte Carlo code for fast dose calculation in magnetic fields. Phys. Med. Biol., 67.10.1088/1361-6560/ac7194 ↗
26. Commissioning of GPU–Accelerated Monte Carlo Code FRED for Clinical Applications in Proton Therapy10.3389/fphy.2020.567300 ↗
27. Capotosti, A., Moretti, R., Milano, A., Nardini, M., Cusumano, D., Annunziata, S., Capogni, M., D’arienzo, M., Placidi, L., and Indovina, L. (2022). Up-to-Date Optimization of the 90Y-PET/CT Reconstruction Protocol for Volumetric Quantification in Trans-Arterial RadioEmbolization (TARE) Procedures in the Era of Theranostics. Appl. Sci., 12.10.3390/app12178418 ↗
28. Berger, M.J., and Seltzer, S.M. (2024, January 18). Stopping Powers and Ranges of Electrons and Positrons. Dic. 1982. Consultato: 4 Luglio 2023. [Online]. Available online: https://ui.adsabs.harvard.edu/abs/1982spre.reptR....B.10.6028/NBS.IR.82-2550 ↗
29. MIRD Pamphlet No. 17: The Dosimetry of Nonuniform Activity Distributions—Radionuclide S Values at the Voxel Level
30. Nelson, A., Swallen, A., Arpidone, M., and Nelson, D. (2017). Dosimetry for Yttrium-90 Microsphere Brachytherapy, MIM Software Inc.
31. DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations10.1088/0031-9155/45/8/315 ↗
32. Comparison of methods: Passing and Bablok regression
33. An interactive website for analytical method comparison and bias estimation10.1016/j.clinbiochem.2017.08.008 ↗
34. Calculation of lung mean dose and quantification of error for 90Y-microsphere radioembolization using 99m Tc-MAA SPECT/CT and diagnostic chest CT10.1002/mp.13575 ↗
35. Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization10.1186/s13550-014-0033-7 ↗
36. Lopez, B., Mahvash, A., Long, J., Lam, M., and Kappadath, S. (2020). Medical Physics, Wiley.
37. Lung shunt and lung dose calculation methods for radioembolization treatment planning10.23736/S1824-4785.20.03287-2 ↗
38. EANM dosimetry committee series on standard operational procedures: A unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres10.1186/s40658-021-00394-3 ↗
39. 90Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction: 90Y -PET quantification10.1118/1.4922685 ↗
40. A new internal pair production branching ratio of 90Y: The development of a non-destructive assay for 90Y and 90Sr10.1016/j.apradiso.2006.08.009 ↗