Partial Discharge Inception Modelling of Insulating Materials and Systems: Contribution of Electrodes to Electric Field Profile Calculation
Source abstract
Abstract
Partial discharge inception modeling is a powerful tool for material investigation and insulation system design in order to achieve the objective of PD-free operation of insulation systems. Model validation, however, requires accurate and repeatable testing conditions, and the aim of this paper is to look at the influence of electrodes and electric field simulation on partial discharge inception model prediction accuracy. Awareness of the geometric electrode configuration is important to forecast both the typology of discharge and the corresponding partial discharge inception voltage value. It is shown, in fact, that inaccurate evaluation of electrode shape (e.g., its flat part and contour) might impact significantly on electric field estimation, the typology of incepted discharges, and, thus, on model accuracy, i.e., on partial discharge inception voltage prediction, which is the basis for the partial discharge-free design of insulating materials and systems. In particular, small electrode curvature radius variations do not significantly affect the PDIV value or PD typology identification. However, worsening electrode/insulation specimen contact can significantly impact PD inception and typology evaluation.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: High voltage insulation and dielectric phenomena · Power Transformer Diagnostics and Insulation · Lightning and Electromagnetic Phenomena
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Dipartimento di Ingegneria Industriale, Università degli Studi di Padova, 35131 Padova, Italy
Center for Advanced Power Systems, Florida State University, Tallahassee, FL 32310, USA
References (21)
Show source-provided references
1. Partial discharge diagnostics and electrical equipment insulation condition assessment10.1109/TDEI.2005.1522184 ↗
2. Partial discharge signal interpretation for generator diagnostics10.1109/TDEI.2005.1430399 ↗
3. Kreuger, F.H. (1990). Partial Discharge Detection in High-Voltage Equipment, Butterworth-Heinemann.
4. (2011). Evaluation and Qualification of Electrical Insulation Systems (Standard No. IEC 60505).
5. (2018). Partial Discharge Free Electrical Insulation Systems (Type I) Used in Rotating Electrical Machines Fed from Voltage Converters—Qualification and Quality Control Tests (Standard No. IEC 60034-18-41).
6. (2017). Off-Line Measurement of Partial Discharge Inception Voltage on Winding Insulation under Repetitive Impulse Voltage (Standard No. IEC 60034-27-5).
7. Nya, B.H., Brombach, J., and Schulz, D. (2012, January 16–18). Benefits of Higher Voltage Levels in Aircraft Electrical Power Systems. Proceedings of the 2012 Electrical Systems for Aircraft, Railway and Ship Propulsion, Bologna, Italy.10.1109/ESARS.2012.6387381 ↗
8. Zhang, X., and Haran, K.S. (2016, January 18–22). High-specific-power electric machines for electrified transportation applications-technology options. Proceedings of the IEEE Energy Conversion Congress and Exposition (ECCE), Milwaukee, WI, USA.10.1109/ECCE.2016.7855164 ↗
9. A Comprehensive Overview of Power Converter Applied in High-Power Wind Turbine: Key Challenges and Potential Solutions10.1109/TPEL.2023.3234221 ↗
10. A new approach to the design of surface subsystems of polymeric insulators for HV and MV apparatus under AC voltage10.1049/hve2.12334 ↗
11. Lizcano, M., Williams, T.S., Shin, E.E., Santiago, D., and Nguyen, D. (2022). Aerospace Environmental Challenges for Electrical Insulation and Recent Developments for Electrified Aircraft. Materials, 15.10.3390/ma15228121 ↗
12. (2014). Electrical Insulating Materials—A.C. Voltage Endurance Evaluation (Standard No. IEC 61251).
13. (2013). Parts 1–7, Guide for the Determination of Thermal Endurance Properties of Electrical Insulating Materials (Standard No. IEC 60216).
14. (2007). Guide for the Statistical Analysis of Electrical Insulation Breakdown Data (Standard No. IEC 62539).
15. A generalized approach to partial discharge modeling10.1109/94.407017 ↗
16. Derivation of a Surface Discharge Model for the Design of the Surface Components of Insulation Systems used in Industrial Electronics Environments10.1109/JESTIE.2022.3221001 ↗
17. Montanari, G.C., Schwartz, S., Yang, Q., Nath, D., Ghosh, R., and Cuzner, R. (2022, January 13–18). Towards Partial Discharge Automatic and Unsupervised Monitoring: A Technological Breakthrough for MV Electrical Asset Condition Monitoring and Diagnostics. Proceedings of the 2022 9th International Conference on Condition Monitoring and Diagnosis (CMD), Kitakiushu, Japan.10.23919/CMD54214.2022.9991273 ↗
18. Digital detection and fuzzy classification of partial discharge signals10.1109/TDEI.2002.1007695 ↗
19. Partial discharges in DC electrical insulation during voltage transients and steady state: Noise rejection, discharge source identification and life estimation10.1016/j.epsr.2021.107117 ↗
20. (2015). High-Voltage Test Techniques—Partial Discharge Measurements (Standard No. IEC 60270).
21. BIPM, IEC, IFCC, ILAC, ISO, IUPAC, IUPAP, and OIML (2011). Guide to the Expression of Uncertainty in Measurement, Morgan & Claypool Publishers. GUM 1995 with Minor Corrections; Joint Committee for Guides in Metrology, JCGM 100:2008.