journal article·2022-05-19Open access

Finite Element Comparative Analysis of Von Mises Stress Levels in Unilateral Removable Partial Denture with and without Distal Implant

Oana Cella Andrei, Livia Alice Tănăsescu, Ioana Daniela Tărlungeanu, Magdalena Natalia Dina, Mircea Horia Tierean

Applied Sciences· Volume 12· Issue 10

Abstract

The aim of this paper is to compare von Mises stress levels and displacements between two possible designs of a class II Kennedy unilateral removable partial denture. Finite element analysis was used to compare two unilateral class II Kennedy removable partial dentures replacing a mandibular second premolar, and first and second molars and with the same design, except a distal implant. The 3D model was created for a mandibular RPD with three artificial teeth and double ball attachment on the abutment teeth and a horizontal ball attachment for the implant, using Autodesk Inventor 2022 software. On the saddle, significant differences appear only when force is applied on the second molar. Association with implant increases von Mises stresses on the acrylic saddle, where displacements values are similar, and decreases von Mises stresses on the muco-osseous support, where displacements values are also similar. Regarding metal reinforcement of the denture, von Mises stress values are greater for forces applied on the second premolar in the implant situation, and smaller for forces applied on the first and second molars. Association with implant decreases von Mises stresses on the metal reinforcement of the denture only if the force is applied distally, on the two molars; in this case, the metal reinforcement is more stressed above the mesial double ball attachment, where displacements values are similar. Regarding the artificial teeth, adding a distal implant does not significantly influence the stress and displacements values, except on the second premolar where the von Mises stresses values are greater, where displacements values are similar. Although an association with an implant increases the risk of fracture for the denture, the results demonstrate that in the posterior area of the edentulous space, the denture exerts less pressure on the mucosa and subjacent bone, protecting the area against resorption.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Removable Prosthodontics, Faculty of Dentistry, University of Medicine and Pharmacy “Carol Davila” Bucharest, 37 Dionisie Lupu Street, 020021 Bucharest, Romania

Department of Dental Techniques, Faculty of Midwifery and Nursing, University of Medicine and Pharmacy “Carol Davila” Bucharest, 37 Dionisie Lupu Street, 020021 Bucharest, Romania

Materials Engineering and Welding Department, Transilvania University of Brasov, 29 Eroilor Blvd., 500036 Brasov, Romania

References (23)

Show source-provided references
1. Comparative study of two different designs of partial over denture supported with distal implant for the treatment of mandibular Kennedy class II cases10.1016/j.tdj.2013.08.002 ↗
2. Connectors and attachments in oral rehabilitation10.4103/2277-8632.117205 ↗
3. Implant-assisted removable partial denture: An approach to switch Kennedy Class I to Kennedy Class III10.4103/0972-4052.179262 ↗
4. Clinical effectiveness of implant support for distal extension removable partial dentures: Functional evaluation using occlusal force measurement and masticatory efficiency10.1186/s40729-021-00381-4 ↗
5. Technical tips for improved retention and stabilization of a unilateral removable partial denture10.1563/1548-1336(2007)33[344:TTFIRA]2.0.CO;2 ↗
6. Effects of rigid and nonrigid extracoronal attachments on supporting tissues in extension base partial removable dental prostheses: A nonlinear finite element study10.1016/S0022-3913(11)60066-8 ↗
7. Wang, S., Shen, Y., Fuh, L., Peng, S., Tsai, M., Huang, H., and Hsu, J. (2020). Relationship between Cortical Bone Thickness and Cancellous Bone Density at Dental Implant Sites in the Jawbone. Diagnostics, 10.10.3390/diagnostics10090710 ↗
8. Misch, C.E. (2008). Contemporary Implant Dentistry, Mosby Elsevier. [3rd ed.].
9. Determination of tangential and normal components of oral forces10.1590/S1678-77572007000100015 ↗
10. Influence of loading positions of mandibular unilateral distal extension removable partial dentures on movements of abutment tooth and denture base
11. Comparative analysis of unilateral removable partial denture and classical removable partial denture by using finite element method10.2298/SARH1012706R ↗
12. Andrei, O.C., Dăguci, C., Ţierean, M.H., Farcaşiu, T.A., Farcaşiu, C., and Tănăsescu, L.A. (2015, January 19–21). Compared stress levels of removable partial dentures with attachments with and without distal implants—A finite element analysis. Proceedings of the 2015 E-Health and Bioengineering Conference (EHB), Iasi, Romania.10.1109/EHB.2015.7391503 ↗
13. Three-dimensional finite element analysis of implant-assisted removable partial dentures10.1016/j.prosdent.2016.09.021 ↗
14. Free-end saddle length influence on stress level in unilateral complex partial denture abutment teeth and retention elements10.2298/VSP110603028P ↗
15. Biomechanics in Removable Partial Dentures: A Literature Review of FEA-Based Studies10.1155/2021/5699962 ↗
16. Mechanical behavior of implant assisted removable partial denture for Kennedy class II10.4317/medoral.56533 ↗
17. Effect of Implant Position and Edentulous Span Length on Stresses Around Implants Assisting Claspless Distal Extension Partial Overdentures: An In Vitro Study10.1563/aaid-joi-D-16-00075 ↗
18. Implant-supported mandibular removable partial dentures: Functional, clinical and radiographical parameters in relation to implant position10.1111/cid.12484 ↗
19. Complication and management of implant-assisted removable partial denture with distal extension: A clinical report10.14368/jdras.2016.32.4.338 ↗
20. Effect of Two Implant-supported Partial Overdenture Attachment Design on the Periodontal Health10.5005/jp-journals-10024-2730 ↗
21. Treatment outcomes of implant-assisted removable partial denture with distal extension based on the Kennedy classification and attachment type: A systematic review10.1186/s40729-021-00394-z ↗
22. Prognosis of Combining Remaining Teeth and Implants in Double-Crown-Retained Removable Dental Prostheses: A Systematic Review and Meta-Analysis10.11607/jomi.5796 ↗
23. Prognosis of implants and abutment teeth under combined tooth-implant-supported and solely implant-supported double-crown-retained removable dental prostheses10.1111/clr.12197 ↗