journal article·2026-04-28Open access

Drying Shrinkage of Cast-In-Situ Concrete in Half-Precast Concrete System Under Restraint Conditions

Sun-Jin Han, Seung-Ho Choi, Hyo Eun Joo, Hyun Kang, Kang Su Kim

Abstract

In half-precast concrete (PC) systems, the drying shrinkage of cast-in-place (CIP) concrete is significantly greater than that of PC slabs, which are typically manufactured in factories using well-controlled steam curing. In actual construction, however, the drying shrinkage of the CIP concrete is restrained by surrounding structural elements. Despite its importance, research involving field measurements of drying shrinkage in actual half-PC construction sites remains limited. Thus, in this study, field measurements were performed to investigate the effects of restraint by reinforcing bars in topping slab, PC slab, and PC column on drying shrinkage of CIP concrete. To this end, strain gauges for measuring drying shrinkage and thermocouples for recording temperature changes were embedded in a real construction site where the half-PC system was applied. Drying shrinkage was then measured over a period of 508 days. The results demonstrated that KDS 14 20 standard provided the most accurate predictions on the free shrinkage, and that the drying shrinkage of CIP concrete decreased by 30–67% compared to the free shrinkage. This indicates that drying shrinkage in actual construction environments can be reduced due to restraint provided by surrounding structural elements. Based on the measurement results, this study proposed a simple model capable of considering the effect of restraints, and its validity was investigated by comparing analysis and field measurement results. Consequently, it appeared that when the axial stiffness of the reinforcing bars was reflected, the closest prediction results were obtained with an average error of 30.7%. However, the applicable range of the proposed model should be limited to specific structural conditions due to modeling assumptions and insufficient field data. The model is suitable for one-way half-PC systems with simple reinforcement layout, where the reinforcement ratio of the CIP concrete ranges from 0.0017 to 0.002, the topping slab thickness is less than 100 mm, and the PC column dimensions are within 500 mm × 500 mm. Additionally, the top surface of the PC slab must be intentionally roughened to ensure full composite action with the topping concrete.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete Properties and Behavior · Innovations in Concrete and Construction Materials · Construction Engineering and Safety

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. ACI 209R. (2008). Prediction of creep, shrinkage, and temperature effects in concrete structures, ACI 209R-92. American Concrete Institute, Farmington Hills.
2. Comité Euro-International du Béton (CEB). (1993). CEB-FIP model code 1990. Comité Euro-International du Béton.10.1680/ceb-fipmc1990.35430 ↗
3. Han, C. G., Han, M. C., Song, S. H., & Yoon, S. (2006). Drying shrinkage of concrete combining expansive additives and shrinkage reducing agent. Journal of the Korea Concrete Institute, 18(3), 397–404. https://doi.org/10.4334/JKCI.2006.18.3.39710.4334/JKCI.2006.18.3.397 ↗
4. Han, S., Joo, H. E., Kim, J. H., Heo, I., & Kim, K. S. (2024). Web-shear capacities of composite hollow-core slabs with core-filling and topping concretes. Structural Concrete, 25(4), 2624–2642. https://doi.org/10.1002/suco.20230033410.1002/suco.202300334 ↗
5. Han, S.-J., Lee, D., & Kim, K. S. (2021). Web-shear capacity of prestressed composite inverted multi-tee slabs. ACI Structural Journal, 118(3), 295–304. https://doi.org/10.14359/5173053810.14359/51730538 ↗
6. International Federation for Structural Concrete (fib). (2024), fib model code for concrete structures (2020). Lausanne, Switzerland: Comité Euro-International du Béton
7. Ju, H., Han, S.-J., Joo, H. E., Cho, H.-C., Kim, K. S., & Oh, Y.-H. (2018). Shear performance of optimized-section precast slab with tapered cross section. Sustainability, 11(1), Article 163. https://doi.org/10.3390/su1101016310.3390/su11010163 ↗
8. Kipkemboi, B., & Miyazawa, S. (2025). Evaluating the influence of drying shrinkage on cracking resistance of massive self-compacting concrete with blast furnace slag using finite element method. Infrastructures, 10(1), Article 11. https://doi.org/10.3390/infrastructures1001001110.3390/infrastructures10010011 ↗
9. Korea Concrete Institute. (2021). Explanation of standards for concrete structure design. Korea Concrete Institute.
10. Korean Design Standard. (2021). KDS 14 20 01—General standards for design of concrete structures (ultimate strength design method). Korea Construction Standards Center.
11. Lee, D. K., Lee, K. C., Lee, C. D., & Shin, K. J. (2019). Study on ECC tensile behavior due to constrained drying shrinkage. Journal of the Korean Recycled Construction Resources Institute, 7(4), 367–374.
12. MacGregor, J. G., & Wight, J. K. (2006). Reinforced Concrete Mechanics and Design (4th ed.). Prentice-Hall.
13. Tokyo Measuring Instruments Laboratory. (2025). TML STRAIN GAUGES. (Ltd. Tokyo Measuring Instruments Laboratory Co., Ed.). Tokyo, Japan.
14. Tongaroonsri, S. (2009). Prediction of autogenous shrinkage, drying shrinkage and shrinkage cracking in concrete (Master Thesis). Bangkok, Thailand: Thammasat University.
15. Yang, E.-I., Kim, I.-S., Yi, S.-T., & Lee, K.-M. (2010). Comparison of measurement methods and prediction models for drying shrinkage of concrete. Journal of the Korea Concrete Institute, 22(1), 85–91. https://doi.org/10.4334/JKCI.2010.22.1.08510.4334/JKCI.2010.22.1.085 ↗
16. Yoo, D.-Y., Park, J.-J., Kim, S.-W., & Yoon, Y.-S. (2011). Characteristics of early-age restrained shrinkage and tensile creep of ultra-high performance cementitious composites (UHPCC). Journal of the Korea Concrete Institute, 23(5), 581–590. https://doi.org/10.4334/JKCI.2011.23.5.58110.4334/JKCI.2011.23.5.581 ↗