Effects of Variation of Axial Load on Seismic Performance of Shear Deficient RC Exterior BCJs
Source abstract
Abstract
The focus of this paper is to investigate the effect of column axial load levels on the performance of shear deficient reinforced concrete beam column joints (BCJs) under monotonic and cyclic loading. The problem of interaction between shear stress in BCJ and axial load on column has been addressed in this work by initially postulating a mechanistic model and substantiated by an experimental test program. This was achieved by conducting appropriate tests on seven BCJ sub-assemblies subjected to monotonic and reversed cyclic loading, with varying levels of the column axial load. Experimental results were further validated using a finite element model in an ABAQUS environment. The effect of variation of compressive strength of concrete was considered in a subsequent parametric study, in order to obtain sufficient data, and utilized to develop a new shear strength model for BCJs which includes influences of all the important parameters required to predict the shear strength of BCJs. The results showed that column axial load affects the seismic performance of BCJs significantly. Experimental results demonstrated that at initial stages of loading, increase in axial load enhances the shear capacity of the joint and reduces its ductility. However, when the column axial load/axial strength ratio increases to about 0.6–0.7, shear strength starts to decrease rapidly, leading to pure axial failure of the joint. The magnitude of axial load/axial capacity ratio also dictates the failure mode and development of crack patterns in BCJs. Results of reverse cyclic tests on BCJs showed that high value of axial load/axial capacity ratio increases the initial stiffness of BCJ but rate of stiffness degradation is accelerated after peak strength attenuation.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Seismic Performance and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. ACI Committee, 318-14. (2014). Building code requirements for structural concrete and commentary.
2. ACI-ASCE Committee 352. (2002). Recommendations for design of beam-column connections in monolithic reinforced concrete structures. Farmington Hills: American Concrete Institute.
3. Al-Osta, M., Al-Khatib, A., Baluch, M., Azad, A., & Rahman, M. (2017). Performance of hybrid beam-column joint cast with high strength concrete. Earthquakes and Structures, 12(6), 603–617.
4. Antonopoulos, C. P., & Triantafillou, T. C. (2003). Experimental investigation of FRP strengthened RC beam-column joints. ACSE Journal of Composites for Construction, 7(1), 39–49.10.1061/(ASCE)1090-0268(2003)7:1(39) ↗
5. Bakir, P. G., & Boduroglu, H. M. (2002). A new design equation for predicting the joint shear strength of monotonically loaded exterior beam-column joints. Engineering Structures, 24(8), 1105–1117.10.1016/S0141-0296(02)00038-X ↗
6. Barnes, M. & Jigoral, S. (2008). Exterior non-ductile beam column joints. University of California, Berkeley, PEER/NEESREU Research Report.
7. Birtel V., & Mark P. (2006). Parameterized finite element modeling of RC beam shear failure. ABAQUS Users’ Conference.
8. Clyde, C., Pantelides, C. P., & Reaveley, L. D. (2000). Performance-based evaluation of exterior reinforced concrete building joints for seismic excitation. PEER Report 2000/05 University of California, Berkeley.
9. Ghobarah, A., & Said, A. (2001). Seismic rehabilitation of beam-column joints using FRP laminates. Journal of Earthquake Engineering, 5(1), 113–129.
10. Hakuto, S., Park, R., & Tanaka, H. (2000). Seismic load tests on interior and exterior beam-column joints with substandard reinforcing details. ACI, Structural Journal, 97(1), 11–25.
11. International Federation for Structural Concrete (fib). (2010). Fib model code for concrete structures, 1.
12. Li, B., Lam, E. S. S., Wu, B., & Wang, Y. (2015). Effect of high axial load on seismic behavior of reinforced concrete beam-column joints with and without strengthening. ACI, Structural Journal, 112(6), 713–723.10.14359/51687938 ↗
13. Masi, A., Santarsiero, G., Mossucca, A., & Nigro, D. (2014). Influence of axial load on the seismic behavior of RC beam-column joints with wide. Applied Mechanics and Materials, 508, 208–214.10.4028/www.scientific.net/AMM.508.208 ↗
14. Masi, A., Santarsiero, G., & Nigro, D. (2013). Cyclic tests on external RC beam-column joints: role of seismic design level and axial load value on the ultimate capacity. Journal of Earthquake Engineering, 17(1), 110–136.10.1080/13632469.2012.707345 ↗
15. Pantelides, C. P., Clyde, C., & Reaveley, D. L. (2002). performance-based evaluation of exterior reinforced concrete building joints for seismic excitation. Earthquake Spectra, 18(3), 449–480.10.1193/1.1510447 ↗
16. Pantelides, C., Okahashi, Y., & Reaveley, L. (2008). Seismic rehabilitation of reinforced concrete frame interior beam-column joints with FRP composites. ASCE, Journal of Composites for Construction, 12(4), 435–445.10.1061/(ASCE)1090-0268(2008)12:4(435) ↗
17. Sarsam, K. F., & Phillips, M. E. (1985). The shear design of in situ reinforced beam-column joints subjected to monotonic loading. Magazine of Concrete Research, 37(130), 16–28.10.1680/macr.1985.37.130.16 ↗
18. Tran, M. T. (2016). Influence factors for the shear strength of exterior and interior reinforced concrete beam-column joints. Sustainable Development of Civil, Urban and Transportation Engineering Conference, Procedia Engineering, 142, 63–70.
19. Vollum, R. L., & Newman, J. B. (1999). The design of external, reinforced concrete beam column joints. The Structural Engineer, 77(23–24), 21–27.
20. Wong, H.F. (2005). Shear strength and seismic performance of non-seismically designed reinforced concrete beam-column joints. PhD Dissertation, Department of Civil Engineering, the Hong Kong University of Science and Technology.