journal article·2018-12Open access

Investigation of Thermal Behaviour of a Hybrid Precasted Concrete Floor using Embedded Sensors

Shane Newell, Jamie Goggins

Abstract

Concrete structures expand and contract in response to temperature changes which can result in structural strain and cracking. However, there is a limited amount of robust field data on hybrid concrete floor structures. Shortage of such data impacts on our understanding of how concrete structures respond to thermal effects and ultimately the overall design of concrete structures. Thus, a comprehensive structural and environmental monitoring strategy was implemented by the authors during the construction of an educational building. Sensors were embedded in the precast and in situ components of a hybrid concrete lattice girder flat slab so that the thermal response of the floor during the manufacture, construction and operational stages could be investigated. Many aspects of the thermal behaviour of the floor during the construction phase were monitored using the embedded sensors. The early-age thermal effects during curing and the impact of the variation of ambient temperature (daily and seasonal) and solar radiation on the behaviour of concrete floor is explored in the paper. Values for restraint factors and the in situ restrained coefficient of thermal expansion of concrete are calculated using the data from the embedded sensors. Numerical modelling of the thermal behaviour of the hybrid concrete floor was undertaken and validated using the real-time field measurements. The data presented and analysed in this paper can be used to improve the understanding and modelling of the thermal behaviour of a hybrid concrete floor. This will assist with improved design of sustainable buildings as it allows the environmental performance of the floor to be optimised with respect to controlling the internal environment, thermal mass and energy efficiency.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Health Monitoring Techniques · Concrete Corrosion and Durability · Smart Materials for Construction

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. ACI (American Concrete Institute). (2002). ACI 207.2R-95 Effect of restraint, volume change, and reinforcement on cracking of mass concrete reported by ACI committee 207, (pp. 1–26). Farmington Hills, MI: ACI.
2. Anson, M., & Rowlinson, P. M. (1988). Early-age strain and temperature measurements in concrete tank walls. Magazine of Concrete Research, 40(145), 216–226.10.1680/macr.1988.40.145.216 ↗
3. Azenha, M., Faria, R., & Ferreira, D. (2009). Identification of early-age concrete temperatures and strains: Monitoring and numerical simulation. Cement and Concrete Composites, 31(6), 369–378.10.1016/j.cemconcomp.2009.03.004 ↗
4. Bamforth, P. (1980). In situ measurement of the effect of partial portland cement replacement using either fly ash or ground granulated blast-furnance slag on the preformance of mass concrete. Proceedings of the Institution of Civil Engineers, 69(2), 777–800.10.1680/iicep.1980.2377 ↗
5. Bamforth, P. (2007). CIRIA report C660: Early-age thermal crack control in concrete. London: CIRIA.
6. Bamforth, P., Chisholm, D., Gibbs, J., & Harrison, T. (2008). Properties of concrete for use in eurocode 2. London: The Concrete Centre.
7. Bentz, D.P. (2000). A computer model to predict the surface temperature and time-of-wetness of concrete pavements and bridge decks, NIST internal report 6551. Maryland, USA: National Institute of Standards and Technology (NIST).
8. Boulay, C., & Paties, C. (1993). Mesure des deformations du beton au jeune. Materials and Structures, 26, 307–311.10.1007/BF02472953 ↗
9. BSI (British Standards Institution). (1985). BS 8110: Structural use of concrete. Part 2: Code of practice for special circumstances. London, UK: BSI.
10. BSI (British Standards Institution). (1998). BS EN 1770: Products and systems for the protection and repair of concrete structures. Test methods. Determination of the coefficient of thermal expansion. London, UK: BSI.
11. BSI (British Standards Institution). (2004). BS EN 1992: Eurocode 2: Design of concrete structures: Part 1-1: General rules and rules for buildings. London, UK: BSI.
12. BSI (British Standards Institution). 2006. BS EN 1992: Eurocode 2: Design of concrete structures. Part 3: Liquid retaining and containment structures. London, UK: BSI.
13. BSI (British Standards Institution). (2009). BS EN 12390-2: Testing hardened concrete. Making and curing specimens for strength tests. London, UK: BSI.
14. Buenfeld, N. R., Davies, R., Karimi, A., & Gilbertson, A. (2008). CIRIA report C661: Intelligent monitoring of concrete structures. London: CIRIA.
15. Crank, J. (1975). The Mathematics of diffusion. Oxford: Clarendon Press.
16. Cusson, D., & Hoogeveen, T. (2007). An experimental approach for the analysis of early-age behaviour of high-performance concrete structures under restrained shrinkage. Cement and Concrete Research, 37(2), 200–209.10.1016/j.cemconres.2006.11.005 ↗
17. DeSchutter, L., & Taerwe, G. (1995). Specific heat and thermal diffusivity of hardening concrete. Magazine of Concrete Research, 47(172), 203–208.10.1680/macr.1995.47.172.203 ↗
18. Dhir, R. K., Zheng, L., & Paine, K. (2008). Measurement of early-age temperature rises in concrete made with blended cements, 60(2), 109–118.
19. Duffó, G. S., & Farina, S. B. (2009). Development of an embeddable sensor to monitor the corrosion process of new and existing reinforced concrete structures. Construction and Building Materials, 23(8), 2746–2751.10.1016/j.conbuildmat.2009.04.001 ↗
20. Ge, Y., Elshafie, M. Z. E. B., Dirar, S., & Middleton, C. R. (2014). The response of embedded strain sensors in concrete beams subjected to thermal loading. Construction and Building Materials, 70, 279–290.10.1016/j.conbuildmat.2014.07.102 ↗
21. Hajdukiewicz, M., Byrne, D., Keane, M., & Goggins, J. (2015). Real-time monitoring framework to investigate the environmental and structural performance of buildings. Building and Environment, 86, 1–16.10.1016/j.buildenv.2014.12.012 ↗
22. Hoseggen, R., Mathisen, H. M., & Hanssen, S. O. (2009). The Effect of suspended ceilings on energy performance and thermal comfort. Energy and Buildings, 41(2), 234–245.10.1016/j.enbuild.2008.09.006 ↗
23. Hover, K. C. (2010). Using human senses to guide concrete construction practice, with examples from the climate of New Zealand. Construction and Building Materials, 24(5), 854–861.10.1016/j.conbuildmat.2009.10.001 ↗
24. IRUSE (Informatics Research Unit for Sustainable Engineering). (2017, August 01). Informatics Research Unit for Sustainable Engineering NUI Galway Weather Website. IRUSE National University of Ireland Galway, Galway, Ireland. Retrieved from http://weather.nuigalway.ie/
25. ISIS Canada (Intelligent Sensing for Innovative Structures). (2005). An introduction to structural health monitoring. ISIS Educational Module No. 5. Winnipeg, Canada: ISIS.
26. Liu, P., Yu, Z., Guo, F., Chen, Y., & Sun, P. (2015). Temperature response in concrete under natural environment. Construction and Building Materials, 98, 713–721.10.1016/j.conbuildmat.2015.07.070 ↗
27. Newell, S., & Goggins, J. (2017). Real-time monitoring of concrete–lattice-girder slabs during construction. Proceedings of the Institution of Civil Engineers-Structures and Buildings, 170(12), 885–900.10.1680/jstbu.16.00198 ↗
28. Newell, S., Goggins, J., Hajdukiewicz, M., & Holleran, D. (2016a). Behaviour of hybrid concrete lattice girder flat slab system using in situ structural health monitoring. In Proceedings of Civil Engineering Research in Ireland Conference (CERI 2016). National University of Ireland, Galway.
29. Newell, S., Hajdukiewicz, M., & Goggins, J. (2016b). Real-time monitoring to investigate structural performance of hybrid precast concrete educational buildings. Journal of Structural Integrity and Maintenance, 1(4), 147–155.10.1080/24705314.2016.1240525 ↗
30. Pour-Ghaz, M., Isgor, O. B., & Ghods, P. (2009). The effect of temperature on the corrosion of steel in concrete. Part 1: simulated polarization resistance tests and model development. Corrosion Science, 51(2), 415–425.10.1016/j.corsci.2008.10.034 ↗
31. Ross, A. D., & Bray, J. W. (1949). The prediction of temperatures in mass concrete by numerical computation. Magazine of Concrete Research, 1(1), 9–20.10.1680/macr.1959.1.1.9 ↗
32. Sofi, M., Mendis, P., Baweja, D., & Mak, S. (2014). Influence of ambient temperature on early age concrete behaviour of Anchorage Zones. Construction and Building Materials, 53, 1–12.10.1016/j.conbuildmat.2013.11.051 ↗
33. The Concrete Society. (2004). In situ concrete strength an investigation into the relationship between core strength and standard cube strength; Project Report No. 3. Camberley, UK: The Concrete Society.
34. Vitharana, N.,& Sakai, K. (1995). Early-age behaviour of concrete sections under strain-induced loadings. In K Satai, N Banthai, & O E Gjorv (Eds.), Proceedings of the 2nd International Conference on Concrete under Severe Conditions CONSEC’95 (pp. 1571–1581). Sapporro, Japan, 2–4 August 1995.
35. Xia, Y., Hao, H., Zanardo, G., & Deeks, A. (2006). Long term vibration monitoring of an rc slab: temperature and humidity effect. Engineering Structures, 28(3), 441–452.10.1016/j.engstruct.2005.09.001 ↗
36. Yuen, K. V., & Kuok, S. C. (2010). Ambient interference in long-term monitoring of buildings. Engineering Structures, 32(8), 2379–2386.10.1016/j.engstruct.2010.04.012 ↗