journal article·2019-12Open access

Transfer Lengths in Pretensioned Concrete Measured Using Various Sensing Technologies

Se-Jin Jeon, Ho Shin, Sang-Hyun Kim, Sung Yong Park, Jun-Mo Yang

Abstract

Although pretensioned concrete structures have increasingly been used worldwide, a number of design issues need to be addressed to further improve the structural performance. Transfer length of pretensioned members was investigated with several test variables in this study by adopting various sensing technologies including the Smart Strands with embedded fiber optic sensors. The effect of increased strength in 2360 MPa high-strength strand on the transfer length was also analyzed. Representative provisions widely used in design were compared with the test results for consistency and appropriate conservatism. The strain distribution required for the transfer length depended partly on the type and location of sensors, which suggests the challenges associated with reasonable determination of the transfer length. According to the results of the analysis, the predictive equation in ACI 318 was relatively accurate and conservative under various conditions including high-strength strands. However, the transfer lengths based on the strand strains rather than the conventional surface strains of concrete require further investigation depending on the bonding behavior between the strand and the surrounding concrete inside a member. Thus, this study also introduces a new sensing technology utilizing the Smart Strand to reliably measure the strain distribution along a strand.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Fiber Optic Sensors · Structural Health Monitoring Techniques · Geotechnical Engineering and Underground Structures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. ACI Committee 318. (2019). Building code requirements for structural concrete (ACI 318-19). Farmington Hills: American Concrete Institute (ACI).
2. ACI Committee 408. (2003). Bond and development of straight reinforcing bars in tension (ACI 408R-03). Farmington Hills: American Concrete Institute (ACI).
3. American Association of State Highway and Transportation Officials (AASHTO). (2017). AASHTO LRFD bridge design specifications (8th ed.). Washington, D.C.: AASHTO.
4. American Society for Testing and Materials (ASTM). (2018). Standard specification for low-relaxation, seven-wire strand for prestressed concrete (ASTM A416/A416M-18). West Conshohocken: ASTM.
5. Bao, Y., Huang, Y., Hoehler, M. S., & Chen, G. (2019). Review of fiber optic sensors for structural fire engineering. Sensors, 19, 877.10.3390/s19040877 ↗
6. Briere, V., Harries, K. A., Kasan, J., & Hager, C. (2013). Dilation behavior of seven-wire prestressing strand—The Hoyer effect. Constr Build Mater, 40, 650–658.10.1016/j.conbuildmat.2012.11.064 ↗
7. British Standards Institution (BSI). (1997). Structural use of concrete (BS 8110). London: BSI.
8. European Committee for Standardization (CEN). (2004). Design of concrete structures (Eurocode 2). Brussels: CEN.
9. Fan, L., Bao, Y., Meng, W., & Chen, G. (2019). In-situ monitoring of corrosion-induced expansion and mass loss of steel bar in steel fiber reinforced concrete using a distributed fiber optic sensor. Compos B Eng, 165, 679–689.10.1016/j.compositesb.2019.02.051 ↗
10. Han, S. J., Park, M. K., Chung, J. H., Kim, K. S., & Seo, S. Y. (2019). Experimental study on transfer length of prestressing strands in UHPC members. J Korea Concr Inst, 31(1), 41–48.10.4334/JKCI.2019.31.1.041 ↗
11. Hayek, C., & Kang, T. H. K. (2017). Elongation tolerance for short tendons in post-tensioned building structures. ACI Struct J, 114(4), 795–802.10.14359/51689619 ↗
12. Huang, Y., Bao, Y., Chen, G., & Zhou, Z. (2019). A constrained cylinder model of strain transfer for packaged fiber Bragg grating sensors embedded in inelastic medium. Struct Contr Health Monit, 26, 2335.10.1002/stc.2335 ↗
13. Huang, Y., & Kang, T. H. K. (2018). Modeling of sliding behavior of unbonded tendons in post-tensioned concrete members. ACI Struct J, 115(4), 1153–1164.10.14359/51702066 ↗
14. Kim, M. S., Han, S. J., Cho, H. C., Oh, J. Y., & Kim, K. S. (2016a). Prediction of transfer lengths in pretensioned concrete members using neuro-fuzzy system. J Korea Concr Inst, 28(6), 723–731.10.4334/JKCI.2016.28.6.723 ↗
15. Kim, S. T., Park, Y. H., Park, S. Y., Cho, K. H., & Cho, J. R. (2015). A sensor-type PC strand with an embedded FBG sensor for monitoring prestress forces. Sensors, 15, 1060–1070.10.3390/s150101060 ↗
16. Kim, S. H., Park, S. Y., Park, Y. H., & Jeon, S. J. (2019). Friction characteristics of post-tensioning tendons in full-scale structures. Eng Struct, 183, 389–397.10.1016/j.engstruct.2019.01.026 ↗
17. Kim, J. K., Yang, J. M., & Yim, H. J. (2016b). Experimental evaluation of transfer length in pretensioned concrete beams using 2,400-MPa prestressed strands. J Struct Eng, 142(11), 04016088.10.1061/(ASCE)ST.1943-541X.0001567 ↗
18. Korea Concrete Institute (KCI). (2012). Structural concrete design code. Seoul: KCI.
19. Korea Institute of Civil Engineering and Building Technology (KICT). (2013). Development of smart prestressing and monitoring technologies for prestressed concrete bridges, KICT 2013-167. Goyang-si: KICT.
20. Korea Road and Transportation Association (KRTA). (2010). Design code for highway bridges. Seoul: KRTA.
21. Korea Road and Transportation Association (KRTA). (2015). Design code for highway bridges (Limit state design). Seoul: KRTA.
22. Korean Agency for Technology and Standards (KATS). (2018). Uncoated stress-relieved steel wires and strands for prestressed concrete (KS D 7002). Seoul: Korean Standards Association (KSA).
23. Martí-Vargas, J. R., García-Taengua, E., & Serna, P. (2013). Influence of concrete composition on anchorage bond behavior of prestressing reinforcement. Constr Build Mater, 48, 1156–1164.10.1016/j.conbuildmat.2013.07.102 ↗
24. Oh, B. H., & Kim, E. S. (2000). Realistic evaluation of transfer lengths in pretensioned, prestressed concrete members. ACI Struct J, 97(6), 821–830.
25. Park, H. (2015). Behavior and analysis of transfer zone in pretensioned prestressed concrete members. Ph.D. Dissertation, Seoul National University, Seoul.
26. Park, H., Din, Z. U., & Cho, J. Y. (2012). Methodological aspects in measurement of strand transfer length in pretensioned concrete. ACI Struct J, 109(5), 625–633.
27. Paul, H. K., Robert, W. L., & Mark, A. M. (1963). Influence of concrete strength on strand transfer length. PCI J, 8(2), 47–67.
28. Precast/Prestressed Concrete Institute (PCI). (2017). PCI design handbook: Precast and prestressed concrete (8th ed.), MNL-120-17. Chicago: PCI.
29. Russell, B. W., & Burns, N. H. (1996). Measured transfer lengths of 0.5 and 0.6 in. strands in pretensioned concrete. PCI J, 41(5), 44–65.10.15554/pcij.09011996.44.65 ↗
30. The International Federation for Structural Concrete (fib). (2013). fib model code for concrete structures 2010. Lausanne: fib.