journal article·2020-06-23Open access

Numerical Analysis of Urine Flow with Multiple Sizes of Double-J Stents

Hyoung-Ho Kim, Kyung-wuk Kim, Young Ho Choi, Seung Bae Lee, Yasutaka Baba

Applied Sciences· Volume 10· Issue 12

Abstract

This study investigated which sizes of double-J stents are more effective in achieving an acceptable urine flow through stenotic and stented ureters. Sixty four computational fluid dynamics models of the combinations of two different gauge ureters (4.57 mm and 5.39 mm in diameter) with four different levels of ureteral and four different sizes of double-J stents were developed for the numerical analysis of urine flow in the ureter. Luminal, extraluminal, and total flow rates along the ureter were measured, and the flow patterns around the ports and side holes were investigated. For the 4.57-mm ureter, the total flow rate for each gauge of stent was 23–63 mL/h (5 Fr), 20–47 mL/h (6 Fr), 17–35 mL/h (7 Fr), and 16–26 mL/h (8 Fr) and for the 5.39-mm ureter, the total flow rate for each gauge of stent was 43–147 mL/h (5 Fr), 36–116 mL/h (6 Fr), 29–92 mL/h (7 Fr), and 26–71 mL/h (8 Fr). With a 74% stenosis, all stents allowed a low flow rate, and the differences in flow rates between the stents were small. At the other levels of stenosis, 5 Fr stents allowed greater flow rates than the 8 Fr stents. The luminal flow rate increased just before the area of stenosis and decreased after the stenosis because of the increase and decrease in the luminal flow through the side holes before and after the stenosis. Therefore, a larger double-J stent is not favorable in achieving an acceptable urine flow through the stenotic and stented ureters. The results in this study could not be necessarily correlated with clinical situation because peristalsis, viscosity of the urine and real format of the ureter were not considered in our model. In vivo experiments are necessary for confirmation of our findings. Double J stents are commonly used in the ureteral stenosis or occlusion, especially due to ureter stones which obstruct the flow of urine. Clinicians choose the size of double J stent on the basis of their clinical experience. Here, we tried to know which sizes of double J stents are better for sufficient urine flow. According to various documents that try to determine the optimal shape of double J stents to increase the urine flow through the ureter, mostly bigger stent is recommended to occur maximum urine flow. However, in case of ureter with stenosis or occlusion, the right size of the double J stent may vary depending on the degree of stenosis in the ureter. To find appropriate stent size for the ureter with stenosis, computational fluid dynamics was conducted. This study shows that smaller diameter stents are more appropriate than larger diameter stents depending on the situation.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Pediatric Urology and Nephrology Studies · Kidney Stones and Urolithiasis Treatments · Ureteral procedures and complications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Mechanical Engineering, Gyeongnam National University of Science And Technology, Gyeongnam, Jinju 52725, Korea

Department of Mechanical Engineering, Soongsil University, Seoul, 06978 Korea

Department of Radiology, Seoul National University, Boramae Hospital, Seoul 07061, Korea

Department of Urology, Seoul National University, Boramae Hospital, Seoul 07061, Korea

Department of Radiology, Saitama medical University, Hidaka-City 1397-1, Japan

Funding

Seoul Metropolitan Government Seoul National University Boramae Medical Center · National Research Foundation of Korea

References (24)

Show source-provided references
1. Vahidi, B., Fatouraee, N., Imanparast, A., and Moghadam, A.N. (2011). A mathematical simulation of the ureter: Effects of the model parameters on ureteral pressure/flow relations. J. Biomech. Eng., 133.10.1115/1.4003316 ↗
2. A biomechanical simulation of ureteral flow during peristalsis using intraluminal morphometric data10.1016/j.jtbi.2011.12.019 ↗
3. Management of nephrostomy drains and ureteral stents10.1053/j.tvir.2009.09.003 ↗
4. Polymers as ureteral stents10.1089/end.2009.0516 ↗
5. Ureteral stents: New ideas, new designs10.1177/1756287210370699 ↗
6. Ureteral stenting and urinary stone management: A systematic review10.1016/j.juro.2007.09.026 ↗
7. Multicenter experience of the newly designed covered metallic ureteral stent for malignant ureteral occlusion: Comparison with double J stent insertion10.1007/s00270-013-0675-2 ↗
8. Nephroureteral stents: Principles and techniques. In: Seminars in interventional radiology
9. Experience with new double J ureteral catheter stent10.1016/S0022-5347(17)57326-7 ↗
10. Double-J and diversion stents10.1016/S0094-0143(21)00719-9 ↗
11. In vitro evaluation of ureteral stent compression10.1016/j.urology.2005.10.038 ↗
12. Mechanism of ureteral stent flow: A comparative in vivo study10.1089/end.1999.13.269 ↗
13. Numerical analysis of the urine flow in a stented ureter with no peristalsis10.3233/BME-151308 ↗
14. McFedries, P. (2007). Formulas and Functions with Microsoft Office Excel USA.
15. The diagnosis of upper urinary tract obstruction10.1046/j.1464-410x.1999.00118.x ↗
16. Kim, K.W., Choi, Y.H., Lee, S.B., Baba, Y., Kim, H.H., and Suh, S.H. (2017). Analysis of Urine Flow in Three Different Ureter Models. Comput. Math. Methods Med.10.1155/2017/5172641 ↗
17. Ansys Inc. (2016). ANSYS-CFX Release 16, Ansys Inc.
18. Investigating the flow dynamics in the obstructed and stented ureter by means of a biomimetic artificial model10.1371/journal.pone.0087433 ↗
19. Kim, K.W., Kim, H.H., Choi, Y.H., Lee, S.B., and Baba, Y. (2020). Urine flow analysis using double J stents of various sizes in in vitro ureter models. Int. J. Numer. Methods Biomed. Eng., e3294.10.1002/cnm.3294 ↗
20. The use of metallic stents to bypass ureteral strictures secondary to metastatic prostate cancer: Experience with 8 patients10.1097/00005392-199707000-00014 ↗
21. Impact on ureteral peristalsis in a stented ureter. An experimental study in the pig10.1007/s00240-002-0258-1 ↗
22. Impact of a double-pigtail stent on ureteral peristalsis in the porcine model: Initial studies using a novel implantable magnetic sensor10.1089/end.2005.19.170 ↗
23. Ureteric drainage and peristalsis after stenting studied using colour Doppler ultrasound10.1046/j.1464-410X.1996.09298.x ↗
24. The effects of double J stenting on unobstructed ureters. An experimental and clinical study10.1111/j.1464-410X.1985.tb07021.x ↗