The OptoGait Motion Analysis System for Clinical Assessment of 2D Spatio-Temporal Gait Parameters in Young Adults: A Reliability and Repeatability Observational Study
Source abstract
Abstract
Background: Walking clinical assessments are commonly used to check for possible gait modifications in healthy subjects, in patients with trauma or neurological conditions, or after a surgical procedure. Spatio-temporal walking variables are studied in depth to achieve a complete evaluation. The purpose of this study was to perform an observational study of the reliability and repeatability of the OptoGait portable photoelectric cell system. Methods: An observational study of the reliability and repeatability of the OptoGait portable photoelectric cell system was carried out. Results: Walking point, walking point gap, step width, and walking base variables, which are deeply related to gait and posture, have an almost perfect reliability. Conclusion: The OptoGait motion analysis device is a reliable system for clinical assessment of static and dynamic foot pressures. Clinicians should feel confident adding this analysis system to their daily professional tools where repeatable measures of gait measurements are important for diagnosis and treatment selection, and also compare efficacy or testing differences between different pathologic conditions. Further, these obtained data can be formed as a baseline for future studies, and to check a right sample size for new research that use the OptoGait motion analysis system.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Diabetic Foot Ulcer Assessment and Management · Lower Extremity Biomechanics and Pathologies · Non-Invasive Vital Sign Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Health Sciences, Universidad Rey Juan Carlos, 28922 Alcorcon, Spain
School of Nursing, Physiotherapy and Podiatry, Universidad Complutense de Madrid, 28040 Madrid, Spain
Department of Psychology, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain
References (14)
Show source-provided references
1. Agreement between spatiotemporal parameters from a photoelectric system with different filter settings and high-speed video analysis during running on a treadmill at comfortable velocity10.1016/j.jbiomech.2019.06.017 ↗
2. Agreement Between the Spatiotemporal Gait Parameters of Healthy Adults From the OptoGait System and a Traditional Three-Dimensional Motion Capture System10.1115/1.4041619 ↗
3. Validation of the OptoGait System for Monitoring Treatment and Recovery of Post-Concussion Athletes10.1016/j.jcm.2016.12.001 ↗
4. Interrater reliability of videotaped observational gait-analysis assessments10.1093/ptj/71.6.465 ↗
5. Reliability of observational kinematic gait analysis10.1093/ptj/65.7.1027 ↗
6. In defence of gait analysis. Observation and measurement in gait assessment10.1302/0301-620X.67B2.3980533 ↗
7. The influence of childhood obesity on spatio-temporal gait parameters10.1016/j.gaitpost.2019.03.031 ↗
8. Intra-rater and inter-rater reliability of gait measurements with CODA mpx30 motion analysis system10.1016/S0966-6362(02)00051-6 ↗
9. Concurrent validity and test-retest reliability of the OptoGait photoelectric cell system for the assessment of spatio-temporal parameters of the gait of young adults10.1589/jpts.26.81 ↗
10. Validity of the Optogait photoelectric system for the assessment of spatial-temporal gait parameters10.1016/j.medengphy.2012.06.015 ↗
11. Validity of the GAITRite walkway system for the measurement of averaged and individual step parameters of gait10.1016/j.gaitpost.2004.10.005 ↗
12. Representation of temporal spatial gait parameters using means in adults without impairment
13. The measurement of observer agreement for categorical data10.2307/2529310 ↗
14. Reliability of the OptoGait portable photoelectric cell system for the quantification of spatial-temporal parameters of gait in young adults10.1016/j.gaitpost.2016.08.035 ↗