A Non-Invasive Optical Multimodal Photoplethysmography-Near Infrared Spectroscopy Sensor for Measuring Intracranial Pressure and Cerebral Oxygenation in Traumatic Brain Injury
Source abstract
Abstract
(1) Background: Traumatic brain injuries (TBI) result in high fatality and lifelong disability rates. Two of the primary biomarkers in assessing TBI are intracranial pressure (ICP) and brain oxygenation. Both are assessed using standalone techniques, out of which ICP can only be assessed utilizing invasive techniques. The motivation of this research is the development of a non-invasive optical multimodal monitoring technology for ICP and brain oxygenation which will enable the effective management of TBI patients. (2) Methods: a multiwavelength optical sensor was designed and manufactured so as to assess both parameters based on the pulsatile and non-pulsatile signals detected from cerebral backscatter light. The probe consists of four LEDs and three photodetectors that measure photoplethysmography (PPG) and near-infrared spectroscopy (NIRS) signals from cerebral tissue. (3) Results: The instrumentation system designed to acquire these optical signals is described in detail along with a rigorous technical evaluation of both the sensor and instrumentation. Bench testing demonstrated the right performance of the electronic circuits while a signal quality assessment showed good indices across all wavelengths, with the signals from the distal photodetector being of highest quality. The system performed well within specifications and recorded good-quality pulsations from a head phantom and provided non-pulsatile signals as expected. (4) Conclusions: This development paves the way for a multimodal non-invasive tool for the effective assessment of TBI patients.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Traumatic Brain Injury and Neurovascular Disturbances · Optical Imaging and Spectroscopy Techniques · Non-Invasive Vital Sign Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Research Centre for Biomedical Engineering, City, University of London, London EC1V 0HB, UK
References (30)
Show source-provided references
1. (2021, January 08). Brain Injury Association of America of ABI vs. TBI: What Is the Difference?. Available online: https://www.biausa.org/brain-injury/about-brain-injury/nbiic/what-is-the-difference-between-an-acquired-brain-injury-and-a-traumatic-brain-injury.
2. (2021, January 08). Headway Types of Brain Injury|Headway. Available online: https://www.headway.org.uk/about-brain-injury/individuals/types-of-brain-injury/.
3. Traumatic brain injury: Integrated approaches to improve prevention, clinical care, and research10.1016/S1474-4422(17)30371-X ↗
4. Non-invasive techniques for multimodal monitoring in Traumatic Brain Injury (TBI): Systematic review and meta-analysis10.1089/neu.2020.7266 ↗
5. Monitoring the injured brain10.23736/S0390-5616.18.04465-X ↗
6. Carney, N., Totten, A.M., O’Reilly, C., Ullman, J.S., Hawryluk, G.W.J., Bell, M.J., Bratton, S.L., Chesnut, R., Harris, O.A., and Kissoon, N. (2017). Guidelines for the Management of Severe Traumatic Brain Injury, Brain Trauma Foundation. [4th ed.].10.1227/NEU.0000000000001432 ↗
7. Multimodality Monitoring in the Neurointensive Care Unit: A Special Perspective for Patients with Stroke10.5853/jos.2013.15.2.99 ↗
8. Invasive and noninvasive means of measuring intracranial pressure: A review10.1088/1361-6579/aa7256 ↗
9. Harary, M., Dolmans, R.G.F., and Gormley, W.B. (2018). Intracranial pressure monitoring—Review and avenues for development. Sensors, 18.10.3390/s18020465 ↗
10. A validation method for near-infrared spectroscopy based tissue oximeters for cerebral and somatic tissue oxygen saturation measurements10.1007/s10877-017-0015-1 ↗
11. Impact of Extracranial Contamination on Regional10.1097/ALN.0b013e31824c00d7 ↗
12. Experimental investigation of NIRS spatial sensitivity10.1364/BOE.2.001478 ↗
13. Fischer, G. (2023, January 06). EQUANOX AdvanceTM Sensor. New York. Available online: www.noninequanox.com.
14. (2023, January 06). Corporation Near Infrared Oxygenation Monitor NIRO-200NX. Available online: www.hamamatsu.com.
15. Absolute and Trend Accuracy of a New Regional Oximeter in Healthy Volunteers During Controlled Hypoxia10.1213/ANE.0000000000000474 ↗
16. Roldan, M., and Kyriacou, P.A. (2021). Near-Infrared Spectroscopy (NIRS) in Traumatic Brain Injury (TBI). Sensors, 21.10.3390/s21051586 ↗
17. Abay, T.Y., Phillips, J.P., Uff, C., Roldan, M., and Kyriacou, P.A. (2022). In Vitro Evaluation of a Non-Invasive Photoplethysmography Based Intracranial Pressure Sensor. Appl. Sci., 13.10.3390/app13010534 ↗
18. Kyriacou, P.A., and Allen, J. (2021). Photoplethysmography Technology, Signal Analysis and Applications, Elsevier.
19. Reflectance photoplethysmography for non-invasive monitoring of tissue perfusion
20. Suzuki, S., Takasaki, S., Ozaki, T., and Yukio, K. (1999, January 15). A tissue oxygenation monitor using NIR spatially resolved spectroscopy. Proceedings of the SPIE Conference on Optical Tomography and Spectroscopy of Tissue III, San Jose, CA, USA.10.1117/12.356862 ↗
21. Roldan, M., Chatterjee, S., and Kyriacou, P.A. (2021, January 26). Light-Tissue Interaction Modelling of Human Brain towards the Optical Sensing of Traumatic Brain Injury. Proceedings of the 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Jalisco, Mexico.
22. Noninvasive Pulse Oximetry Utilizing Skin Reflectance Photoplethysmography10.1109/10.7286 ↗
23. Biocompatible, High Precision, Wideband, Improved Howland Current Source With Lead-Lag Compensation10.1109/TBCAS.2012.2199114 ↗
24. Roldan, M., and Kyriacou, P.A. (Photonics, 2023). Development of a head phantom for the acquisition of pulsatile optical measurements: Mimicking Blood and CSF circulation, Photonics, in press.
25. Elgendi, M. (2016). Optimal signal quality index for photoplethysmogram signals. Bioengineering, 3.10.3390/bioengineering3040021 ↗
26. Orphanidou, C. (2018). Signal Quality Assessment in Physiological Monitoring, Springer International Publishing. SpringerBriefs in Bioengineering.10.1007/978-3-319-68415-4 ↗
27. Two-stage approach for detection and reduction of motion artifacts in photoplethysmographic data10.1109/TBME.2009.2039568 ↗
28. Elgendi, M., Norton, I., Brearley, M., Abbott, D., and Schuurmans, D. (2013). Systolic Peak Detection in Acceleration Photoplethysmograms Measured from Emergency Responders in Tropical Conditions. PLoS ONE, 8.10.1371/journal.pone.0076585 ↗
29. Kim, J., Kim, J., and Ko, H. (2016). Low-power photoplethysmogram acquisition integrated circuit with robust light interference compensation. Sensors, 16.10.3390/s16010046 ↗
30. Photoplethysmogram Analysis and Applications: An Integrative Review10.3389/fphys.2021.808451 ↗