Experimental Dynamic Response of a Multi-Story Frame Structure Equipped with Non-Conventional TMD Implemented via Inter-Story Isolation
Source abstract
Abstract
A shaking table experiment conducted on a multi-degrees-of-freedom frame structure equipped with a non-conventional tuned mass damper (TMD) is presented. The non-conventional TMD is characterized by a high mass ratio, without adding further structural masses, and is realized via inter-story isolation. The structure top story mass of a four-story steel frame structure is isolated and converted into tuned mass, connecting to the substructure with two high damping rubber bearings placed in series. Aspects related to the dynamic structural response as well as the seismic effectiveness assessment of a non-conventional TMD are addressed. Three structural configurations are tested: the reference four-story structure, the three-story intermediate structure, and the three-story structure equipped with a non-conventional TMD. The input motion conditions considered are: white noise, sine sweep, and natural earthquakes. Through experiments, structural identification is carried out and different dynamic behaviors emerge for the configurations tested. The nonlinear effects provoked on the structure by the adopted isolators are investigated, showing high dissipative capabilities in a wide range of amplitudes of the excitation. It is demonstrated that a non-conventional TMD is a smart control strategy useful for enhancing structural vibration mitigation.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Seismic Performance and Analysis · Vibration Control and Rheological Fluids · Structural Health Monitoring Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Economics, Universitas Mercatorum, Piazza Mattei 10, 00186 Rome, Italy
Department of Structural and Geotechnical Engineering, Sapienza University of Rome, Via Eudossiana 18, 00184 Rome, Italy
Funding
Progetto Sapienza
References (26)
Show source-provided references
1. Soong, T.T., and Dargush, G.F. (1997). Passive Energy Dissipation Systems in Structural Engineering, John Wiley & Sons.
2. Reggio, A., and De Angelis, M. (July, January 30). Optimization of a non-conventional TMD implemented via inter-storey isolation. Proceedings of the 9th International Conference on Structural Dynamics, Eurodyn, Porto, Portugal.
3. Optimal energy-based seismic design of non-conventional Tuned Mass Damper (TMD) implemented via inter-story isolation10.1002/eqe.2548 ↗
4. Vibration control of tall buildings using mega subconfiguration10.1061/(ASCE)0733-9399(1995)121:10(1082) ↗
5. Vibration control parameters investigation of the mega-sub controlled structure system (MSCSS)10.12989/eas.2013.5.2.225 ↗
6. Aseismic roof isolation system built with steel oval elements10.1193/1.1850528 ↗
7. Pagliaro, S., and Di Egidio, A. (2022). Archetype Dynamically Equivalent 3-DOF Model to Evaluate Seismic Performances of Intermediate Discontinuity in Frame Structures. J. Eng. Mech., 148.10.1061/(ASCE)EM.1943-7889.0002083 ↗
8. Top disconnection versus base disconnection in structures subjected to harmonic base excitation10.1016/j.engstruct.2017.09.041 ↗
9. Faiella, D., and Mele, E. (2020). Insights into inter-story isolation design through the analysis of two case studies. Eng. Struct., 215.10.1016/j.engstruct.2020.110660 ↗
10. Seismic Retrofit of Existing Masonry Buildings through Inter-story Isolation System: A Case Study and General Design Criteria10.1080/13632469.2020.1752854 ↗
11. Investigation on the optimal properties of semi active control devices with continuous control for equipment isolation
12. Optimal design and performance evaluation of systems with Tuned Mass Damper Inerter. (TMDI)10.1002/eqe.2861 ↗
13. Pietrosanti, D., De Angelis, M., and Basili, M. (2020). A generalized 2-DOF model for optimal design of MDOF structures controlled by Tuned Mass Damper Inerter (TMDI). Int. J. Mech. Sci., 185.10.1016/j.ijmecsci.2020.105849 ↗
14. De Angelis, M., Giaralis, A., Petrini, F., and Pietrosanti, D. (2019). Optimal tuning and assessment of inertial dampers with grounded inerter for vibration control of seismically excited base-isolated systems. Eng. Struct., 196.10.1016/j.engstruct.2019.05.091 ↗
15. Liang, Q., Li, L., and Yang, Q. (2020). Seismic analysis of the tuned-inerter-damper enhanced mega-sub structure system. Struct. Contol. Health Monit., 28.10.1002/stc.2658 ↗
16. Wang, Z., and Giaralis, A. (2021). Top-Story Softening for Enhanced Mitigation of Vortex Shedding-Induced Vibrations in Wind-Excited Tuned Mass Damper Inerter-Equipped Tall Buildings. J. Struct. Eng., 147.10.1061/(ASCE)ST.1943-541X.0002838 ↗
17. Saha, A., and Mishra, S.K. (2021). Amplification of seismic demands in inter-storey-isolated buildings subjected to near fault pulse type ground motions. Soil Dyn. Earthq. Eng., 147.10.1016/j.soildyn.2021.106771 ↗
18. Implications of inter-storey-isolation (ISI) on seismic fragility, loss and resilience of buildings subjected to near fault ground motions10.1007/s10518-021-01277-9 ↗
19. Aseismic roof isolation system: Analytic and shake table studies10.1002/(SICI)1096-9845(199903)28:3<217::AID-EQE813>3.0.CO;2-G ↗
20. Dynamic response and optimal design of structures with large mass ratio TMD10.1002/eqe.1117 ↗
21. Shi, S., Du, D., Xu, W., and Wang, S. (2020). Theoretical and experimental study on an innovative seismic retrofit solution for old brick masonry buildings. Eng. Struct., 225.10.1016/j.engstruct.2020.111296 ↗
22. Tronci, E.M., De Angelis, M., Betti, R., and Altomare, V. (2020). Vibration-based structural health monitoring of a RC-masonry tower equipped with non-conventional TMD. Eng. Struct., 224.10.1016/j.engstruct.2020.111212 ↗
23. Basili, M., and De Angelis, M. (2020). Preliminary experimental results of shaking table tests on mdof structure equipped with non-conventional tmd. Lect. Notes Mech. Eng., 223–232.10.1007/978-3-030-41057-5_18 ↗
24. Investigation of a system identification methodology in the context of the ASCE benchmark problem
25. Identification of linear structural systems using earthquake-induced vibration data10.1002/(SICI)1096-9845(199911)28:11<1449::AID-EQE881>3.0.CO;2-5 ↗
26. Discussion of system intrinsic parameters of tuned mass dampers used for seismic response reduction10.1002/stc.1775 ↗