Compressive and Diagonal Tension Strengths of Masonry Prisms Strengthened with Amorphous Steel Fiber-Reinforced Mortar Overlay
Source abstract
Abstract
A technique for strengthening masonry walls by plastering with amorphous steel fiber-reinforced mortar (ASFRM) is investigated through compressive and diagonal tension tests for masonry prisms. The vertical joint between masonry units was not completely filled with mortar to mimic poor workmanship, which is typically reflected in low-cost buildings. The test variables include the number and thickness of mortar overlays, fiber volume fraction, and additional reinforcement using glass fiber mesh or shear connectors. In most strengthened specimens, the ASFRM is not damaged but separated from the masonry prisms after its maximum strength is reached. Additional tests for the bond strength between the ASFRM overlay and masonry surface are conducted to evaluate its contribution to the strengthening effects. Based on experimental observations, equations for predicting the compressive and diagonal tension strengths of masonry prisms strengthened with ASFRM are proposed. The compressive strength can be predicted more accurately by considering the asymmetrical distribution of compressive stress when strengthening is performed on only one side. The diagonal tension strength after strengthening can be predicted by incorporating the contribution of the bond strength between the ASFRM overlay and masonry prism to the initial strength.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Hanwool Structural Engineering, Seoul 04589, Korea
Division of Architecture and Urban Design, Incheon National University, Incheon 22012, Korea
Funding
Ministry of Land, Infrastructure and Transport
References (28)
Show source-provided references
1. FEMA P-774 (2009). Unreinforced Masonry Buildings and Earthquakes.
2. Doğangün, A., Ural, A., and Livaoğlu, R. (2008, January 12–17). Seismic performance of masonry buildings during recent earthqukes in Turkey. Proceedings of the 14th World Conference on Earthquake Engineering (14WCEE), Beijing, China.
3. Modeling strategies for the computational analysis of unreinforced masonry structures: Review and classification10.1007/s11831-019-09351-x ↗
4. An integrated Terrestrial Laser Scanner (TLS), Deviation Analysis (DA) and Finite Element (FE) approach for health assessment of historical structures. A minaret case study10.1016/j.engstruct.2017.10.026 ↗
5. Visual programming for structural assessment of out-of-plane mechanisms in historic masonry structures10.1016/j.jobe.2020.101425 ↗
6. Cyclic shear behavior of masonry walls strengthened with prestressed steel bars and glass fiber grids10.1016/j.compstruct.2020.111961 ↗
7. Diagonal shear behavior of unreinforced masonry wallettes strengthened using twisted steel bars10.1016/j.conbuildmat.2011.04.063 ↗
8. Experimental assessment of in-plane behaviour of three-leaf stone masonry walls10.1016/j.conbuildmat.2013.11.084 ↗
9. Seismic retrofitting of low-rise masonry and concrete walls using steel strips10.1061/(ASCE)0733-9445(2000)126:9(1017) ↗
10. Investigation of in-plane seismic retrofit of unreinforced masonry walls by means of vertical steel ties10.1016/j.conbuildmat.2013.11.020 ↗
11. Numerical analysis of bond behavior between masonry bricks and composite materials10.1016/j.engstruct.2012.05.022 ↗
12. Evaluation of shear strength of unreinforced masonry walls retrofitted by fiber reinforced polymer sheet10.4334/JKCI.2012.24.3.305 ↗
13. Lateral resistance of unreinforced masonry walls strengthened with engineering cementitious composite10.1007/s40999-016-0026-1 ↗
14. Experimental investigation on polymeric net-RCM reinforced masonry panels10.1016/j.compstruct.2013.05.017 ↗
15. Assessment of overlay masonry strengthening system under in-plane monotonic and cyclic loading using the diagonal tensile test10.1016/j.conbuildmat.2015.07.040 ↗
16. In-plane shear strengthening of unreinforced masonry walls using GFRP jacketing
17. In plane behaviour of masonry walls reinforced with mortar coatings and fibre meshes10.1080/15583058.2019.1618972 ↗
18. Experimental study on carbon fiber textile reinforced mortar system as a means for confinement of masonry columns10.1016/j.conbuildmat.2019.03.033 ↗
19. Ombres, L., and Verre, S. (2020). Analysis of the Behavior of FRCM Confined Clay Brick Masonry Columns. Fibers, 8.10.3390/fib8020011 ↗
20. Yu, J.-H., and Park, J.-H. (2020). Investigation of Steel Fiber-Reinforced Mortar Overlay for Strengthening Masonry Walls by Prism Tests. Appl. Sci., 10.10.3390/app10186395 ↗
21. Enhancement of compressive and shear strength for concrete masonry prisms with steel fiber-reinforced mortar overlay10.5000/EESK.2021.25.1.021 ↗
22. Yu, J.H. (2021). Retrofit Effects of Steel Fiber-Reinforced Mortar Plastered on Unreinforced Masonry Walls. [Master’s Degree, Incheon National University].
23. ASTM C1314 (2014). Standard Test Method for Compressive Strength of Masonry Prisms, ASTM International.
24. ASTM E519/E519M (2015). Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages, ASTM International.
25. A study on the dynamic and durability properties of high-ductile mortar using reinforced fiber
26. Korea Construction Standards 41 16 01 (2018). Plaster Work.
27. ASCE 41-17 (2017). Seismic Evaluation and Retrofit of Existing Buildings, ASCE.
28. TMS 402 (2012). Building Code Requirements for Masonry Structures, The Masonry Society.