Analysis of the Influence of Surface Roughness on Measurement of Ultrasonic Nonlinearity Parameter Using Contact-Type Transducer
Source abstract
Abstract
The ultrasonic nonlinearity parameter is used to evaluate the nonlinear elasticity of a material, which is determined from the displacement amplitude of the fundamental and second-order frequencies components in an ultrasonic wave propagating through a material. However, the displacement amplitude of the second-order harmonic component generated during propagation through a material is very weak because it is easily affected by measurement conditions such as surface roughness. In this study, we analyzed the influence of surface roughness on the measurement of the ultrasonic nonlinearity parameter. For this purpose, Al6061-T6 and SUS304 specimens were prepared with different surface roughness ranging from 0.5 to 2.9 μm. Then, the absolute and relative ultrasonic nonlinearity parameter measurements were conducted using a through-transmission technique involving two cases: both surfaces being rough, and one being a rough surface and the other being a smooth surface. The experimental results showed that the surface roughness had a lesser influence on the absolute measurement than on the relative measurement and that the transmission surface was less affected by the reception surface. These results were similar regardless of the types of specimens. Therefore, to perform accurate measurements, it is desirable to measure the nonlinearity parameter after polishing the material surface.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Non-Destructive Testing Techniques · Flow Measurement and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Korea Atomic Energy Research Institute, Daejeon 34057, Korea
Korea Aerospace Industries, Ltd., Sacheon-si 52529, Korea
School of Mechanical Engineering, Hanyang University, Seoul 04763, Korea
Funding
Ministry of Science, ICT & Future Planning · Ministry of Education
References (25)
Show source-provided references
1. Nonlinear ultrasonic techniques for nondestructive assessment of micro damage in material: A review10.1007/s12541-009-0019-y ↗
2. Application of nonlinear ultrasonics to the NDE of material degradation10.1109/58.842040 ↗
3. Effect of precipitate coherency strains on acoustic harmonic generation10.1063/1.364327 ↗
4. Dislocation contribution to the second harmonic generation of ultrasonic waves10.1063/1.1713881 ↗
5. Experimental characterization of fatigue damage in a nickel-base superalloy using nonlinear ultrasonic waves10.1121/1.2221557 ↗
6. Quantitative assessment of fatigue damage accumulation in wavy slip metals from acoustic harmonic generation10.1080/14786430500365358 ↗
7. Modeling nonlinearities of ultrasonic waves for fatigue damage characterization: Theory, simulation, and experimental validation10.1016/j.ultras.2013.09.023 ↗
8. Creep damage characterization using a low amplitude nonlinear ultrasonic technique10.1016/j.matchar.2010.11.007 ↗
9. Evaluation of ultrasonic nonlinear characteristics in heat-treated aluminum alloy (Al-Mg-Si-Cu)
10. Assessment of thermal degradation by cumulative variation of ultrasonic nonlinear parameter10.1007/s12541-017-0003-x ↗
11. Thermal degradation evaluation of HP40Nb alloy steel after long term service using a nonlinear ultrasonic technique10.1007/s10921-013-0222-8 ↗
12. Absolute measurement and relative measurement of ultrasonic nonlinear parameters10.1080/09349847.2016.1174322 ↗
13. Measurement of the acoustic harmonic generation for materials characterization using contact transducers
14. Absolute ultrasonic displacement amplitude measurements with a submersible electrostatic acoustic transducer10.1063/1.1143231 ↗
15. Determination of the nonlinear ultrasonic parameter using a Michelson interferometer10.1088/0957-0233/8/6/009 ↗
16. Rough-surface effects on incoherent scattering from random volumetric scatterers: Approximate analytic series solution10.1121/1.411292 ↗
17. The influence of roughness, angle, range, and transducer type on the echo signal from planar interfaces10.1109/58.911734 ↗
18. Surface roughness induced attenuation of reflected and transmitted ultrasonic waves10.1121/1.395545 ↗
19. Application of air-coupled ultrasound to noncontact surface roughness evaluation10.1143/JJAP.44.4417 ↗
20. Effects of surface roughness and nonparallelism on the measurement of the acoustic nonlinearity parameter in steam turbine blades10.1063/1.1306201 ↗
21. Influence of surface roughness on the measurement of acoustic nonlinearity parameter of solids using contact piezoelectric transducers10.1016/j.ultras.2017.10.022 ↗
22. Effect of window function for measurement of ultrasonic nonlinear parameter using fast fourier transform of tone-burst signal10.7779/JKSNT.2015.35.4.251 ↗
23. Effect of system dependent harmonics in the measurement of ultrasonic nonlinear parameter by using contact transducers
24. Review/Sythèse nonlinear acoustic applications for material characterization: A review10.1139/p99-059 ↗
25. Kim, J., Lee, K.-J., and Jhang, K.-Y. (2016, January 26–31). Comparison of ultrasonic nonlinear parameters measured by PZT and LiNbO3 transducers. Proceedings of the 42nd Annual Review of Progress in Quantitative Nondestructive Evaluation, Minneapolis, MN, USA.10.1063/1.4940514 ↗