This paper describes the design, development and characterisation of an electrochemical biosensor for the measurement of linoleic and α-linolenic acid, as representative free polyunsaturated fatty acids (PUFAs), that may be implicated in food safety and food quality. Initial cyclic voltammetric studies were performed with solutions that contained enzyme-generated hydroperoxides of the two PUFAs. These were examined with plain screen-printed carbon electrodes (SPCEs) and screen-printed carbon electrodes containing the electrocatalyst cobalt phthalocyanine (CoPC). The electrocatalytic oxidation peaks obtained with the latter occurred at potentials about 300 mV lower than the those obtained by direct oxidation with the plain SPCEs and were better defined; as these attributes would lead to better selectivity and sensitivity for fatty acid determinations, the CoPC-SPCEs were used in the fabrication of amperometric biosensors. The enzyme lipoxygenase (LOX) was immobilised on the surface of these devices using the crosslinking agent glutaraldehyde. These biosensors were optimised for the measurement of linoleic and α-linolenic acid using amperometry in stirred solution; the optimum conditions were deduced by studying the effect of enzyme loading, pH and temperature on the amperometric responses. These responses were examined over the concentration range 2.0 to 20 µM and the results indicated that the following conditions were optimal: LOX loading 15 units; pH 8.0; temperature 37 °C. Low concentration calibration studies were performed with the two PUFAs and it was shown that the steady state currents were linear between 0.2 and 10 µM for linoleic acid and 0.2 and 10 µM for α-linolenic acid; the detection limits were 24 and 100 nM, respectively. The precision (coefficient of variation, n = 6) was 5.3% for α-linoleic acid and 3.3% for linoleic acid, which were calculated from the steady state current following additions (n = 6) of 0.2 µM PUFA. These results demonstrate that the novel amperometric biosensor holds promise for determining whether foods contain acceptable levels of free fatty acids.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Advanced Chemical Sensor Technologies · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Centre for Research in Biosciences, Faculty of Health and Applied Sciences, Frenchay Campus, University of the West of England, Coldharbour Lane, Bristol BS16 1QY, UK

Funding

Agriculture and Horticulture Development Board

References (26)

Show source-provided references
1. Dietary fats and coronary heart disease10.1111/j.1365-2796.2012.02553.x ↗
2. Nutrition and healthy ageing: The key ingredients10.1017/S0029665113003881 ↗
3. Development of a cobalt(II) phthalocyanine- MWCNT modified carbon paste electrode for the detection of polyunsaturated fatty acids10.1016/j.aca.2018.07.033 ↗
4. Analytical approaches for the assessment of free fatty acids in oils and fats10.1039/C4AY00344F ↗
5. Comparison between novel and standard methods for analysis of free fatty acids in milk–Including relation to rancid flavour10.1016/j.idairyj.2017.07.001 ↗
6. Sensory Threshold of Off-Flavors Caused by Proteolysis and Lipolysis in Milk10.3168/jds.S0022-0302(03)73745-X ↗
7. Detection and Prediction of Hydrolytic Rancidity in Milk by Multiple Regression Analysis of Short-Chain Free Fatty Acids Determined by Solid Phase Microextraction Gas Chromatography and Quantitative Flavor Intensity Assessment10.1021/jf030347w ↗
8. Direct, reagent-free determination of free fatty acid content in olive oil and olives by Fourier transform Raman spectrometry10.1016/S0003-2670(03)00560-9 ↗
9. Dand, R. (2011). The International Cocoa Trade, Woodhead Publishing Limited. [3rd ed.].
10. Screen-printed carbon based biosensors and their applications in agri-food safety10.1016/j.trac.2020.115898 ↗
11. An electrochemical immunosensor for milk progesterone using a continuous flow system10.1016/S0956-5663(01)00212-3 ↗
12. Development of a disposable screen-printed amperometric biosensor based on glutamate dehydrogenase, for the determination of glutamate in clinical and food applications
13. Development of a simple, low cost chronoamperometric assay for fructose based on a commercial graphite-nanoparticle modified screen-printed carbon electrode10.1016/j.foodchem.2017.08.077 ↗
14. A Screen-Printed, Amperometric, Biosensor Array for the Detection of Organophosphate Pesticides Based on Inhibition of Wild Type, and Mutant Acetylcholinesterases, fromDrosophila melanogaster10.1081/AL-120037590 ↗
15. Novel, rapid, low-cost screen-printed (bio)sensors for the direct analysis of boar taint compounds androstenone and skatole in porcine adipose tissue: Comparison with a high-resolution gas chromatographic method10.1016/j.bios.2019.111837 ↗
16. Smart, A., Westmacott, K.L., Crew, A., Doran, O., and Hart, J.P. (2019). An Electrocatalytic Screen-Printed Amperometric Sensor for the Selective Measurement of Thiamine (Vitamin B1) in Food Supplements. Biosens. Bioelectron., 9.10.3390/bios9030098 ↗
17. Hydroperoxides from oxidation of linoleic and linolenic acids by soybean lipoxygenase: Proof of thetrans-11 double bond10.1007/BF02533062 ↗
18. Voltammetric and photoelectron spectral elucidation of the electrocatalytic oxidation of hydrogen peroxide at screen-printed carbon electrodes chemically modified with cobalt phthalocyanine10.1002/elan.1140070608 ↗
19. Electrocatalytic activity of cobalt phthalocyanine stabilized by different matrixes10.1007/s00216-002-1562-x ↗
20. A novel, disposable, screen-printed amperometric biosensor for glucose in serum fabricated using a water-based carbon ink10.1016/j.bios.2005.01.003 ↗
21. Pletcher, D., Greff, R., Peat, R., Peter, L.M., and Robinson, J. (1990). Instrumental Methods in Electrochemistry, Ellis Horwood Limited. [2nd ed.].
22. Development and Characterization of Cobalt Hexacyanoferrate Modified Carbon Electrodes for Electrochemical Enzyme Biosensors10.1081/AL-120030284 ↗
23. Nanoporous gold supported cobalt oxide microelectrodes as high-performance electrochemical biosensors10.1038/ncomms3169 ↗
24. Enhanced amperometric detection of paracetamol by immobilized cobalt ion on functionalized MWCNTs-Chitosan thin film10.1016/j.ab.2018.05.004 ↗
25. The lipoxygenase sensor, a new approach in essential fatty acid determination in foods10.1016/S0956-5663(97)00073-0 ↗
26. Lipoxygenase-modified Ru-bpy/graphene oxide: Electrochemical biosensor for on-farm monitoring of non-esterified fatty acid10.1016/j.bios.2015.11.058 ↗