journal article·2019-09-27Open access

Comparison of Water Pretreatment Devices for the Measurement of Polar Odorous Compounds

Joo-Yeon Lee, Trieu-Vuong Dinh, Dong-June Kim, In-Young Choi, Ji-Won Ahn, Shin-Young Park, Yoo-Jin Jung, Jo-Chun Kim

Applied Sciences· Volume 9· Issue 19

Abstract

A major problem of measuring polar compounds in the air is water vapor. Therefore, it is important to use a water pretreatment device prior to sampling and analysis. However, many studies have reported the occurrence of many problems following the application of an existing water pretreatment device. Accordingly, the performance of a Desolvator-K that was developed by the authors and two commercial coolers were investigated and compared in this study. Water vapor removal efficiency, recovery rate, and reproducibility of polar odorous compounds (i.e., methyl ethyl ketone (MEK), isobutyl alcohol (i-BuAl), methyl isobutyl ketone (MIBK), butyl acetate (BuAc), styrene) in air were taken into account. It was found that the Desolvator-K, the Cooler-G, and the Cooler-K showed 91.6%, 67.2%, and 62.1% water vapor removal efficiency, respectively, at the relative humidity of 90%. In terms of recovery rate, after water vapor removal devices, the Desolvator-K, the Cooler-G, and the Cooler-K revealed average recoveries of 96.6–103%, 81–101%, and 88.6–100%, respectively. Reproducibility of odorous compounds under all conditions of the Desolvator-K, the Cooler-G, and the Cooler-K were 5.94%, 31.2%, and 8.14% of relative standard deviation (RSD), respectively. Therefore, it is suggested that the Desolvator-K should be established as a water pretreatment device for the MEK, i-BuAl, MIBK, and BuAc compounds in the air.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Chemical Sensor Technologies · Odor and Emission Control Technologies · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil and Environmental Engineering, Konkuk University, 120 Neungdong-ro, Gwangjin-Gu, Seoul 05029, Korea

International Climate and Environmental Research Center, Konkuk University, 120 Neungdong-ro, Gwangjin-Gu, Seoul 05029, Korea

References (31)

Show source-provided references
1. The system for dehumidification of samples in laser gas analysis10.1134/S1024856012010058 ↗
2. Investigation of membrane dryers and evaluation of a new ozone scrubbing material for the sampling of organosulphur compounds in air10.1016/S0021-9673(99)00686-X ↗
3. The use of nafion dryer tubes for moisture removal in flow injection chemical vapor generation atomic absorption spectrometry10.1016/0584-8547(94)00154-N ↗
4. U.S. EPA (1998). Technical Assistance Document for Sampling and Analysis of Ozone Precursors.
5. The Korea Ministry of Environment, and The Korea National Institute of Environmental Research (2018). Air Pollution Monitoring Network Installation and Operation Guidelines, The Korea Ministry of Environment. Available online: http://www.me.go.kr/home/web/public_info/read.do;jsessionid=ZoQ68eydUH63yakjSV1mZ90hrC6nKwmuIaIGNXrdIwh87RtigvMG7pOtmCAYSzFJ.meweb1vhost_servlet_engine1?pagerOffset=0&maxPageItems=10&maxIndexPages=10&searchKey=&searchValue=&menuId=10357&orgCd=&condition.publicInfoMasterId=2&condition.deleteYn=N&publicInfoId=426&menuId=10357.
6. The Korea Ministry of Environment (2018). VOCs-Cold Trap-GC Method—on-Line Monitoring Method (ES 09906.a).
7. (2019, August 01). Perma Pure. Available online: http://www.permapure.com.
8. The Korea National Institute of Environmental Research (2007). Method for the Measurement of Odorants.
9. U.S. EPA (1999). Compendium Method TO-17: Determination of Volatile Organic Compounds in Ambient Air Using Active Sampling Onto Sorbent Tubes.
10. Use of a multi-tube Nafion® membrane dryer for desolvation with thermospray sample introduction to inductively coupled plasma-atomic emission spectrometry10.1016/0584-8547(96)01524-8 ↗
11. Jahnke, J.A. (2000). Continuous Emission Monitoring, John Wiley & Sons. [2nd ed.].
12. Volatile organic compounds up to C20 emitted from motor vehicles; measurement methods10.1016/1352-2310(95)00116-6 ↗
13. Canister-based method for monitoring toxic vocs in ambient air10.1080/10473289.1991.10466924 ↗
14. Analytical method for determination of trace organics in gas samples collected by Canister10.1093/chromsci/29.2.83 ↗
15. Hydrocarbon losses on a regenerated nation® dryer10.1080/10473289.1995.10467379 ↗
16. A Study on the Performanc Optimization of A Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere10.5572/KOSAE.2009.25.6.523 ↗
17. U.S. EPA (1999). Compendium Method TO-14A: Determination Of Volatile Organic Compounds (VOCs), Ambient Air Using Specially Prepared Canisters With Subsequent Analysis By Gas Chromatography.
18. Current Status and Prospective of Hazardous VOC in Ambient Air10.5572/KOSAE.2011.27.6.734 ↗
19. Development of a pretreatment system for the analysis of atmospheric reduced sulfur compounds10.1021/ac401345e ↗
20. Sun, C.Q. (2015). Mpemba Paradox: Hydrogen Bond Memory and Water-Skin Supersolidity. arXiv.10.1007/978-981-4585-21-7_41 ↗
21. The Mpemba effect: When can hot water freeze faster than cold?10.1119/1.2186331 ↗
22. The Korea Ministry of Environment (2008). Annual Environmental Report.
23. (2004). U.S. EPA ISO 16000-6. Indoor Air—Part 6: Determination of Volatile Organic Compounds in Indoor and Test Chamber Air by Active Sampling on Tenax TA® Sorbent, Thermal Desorption and Gas Chromatography Using MS/FID, ISO Copyright Office.
24. (2003). U.S. EPA ISO 16017-2. Indoor, Ambient and Workplace Air—Sampling and Analysis of Volatile Organic Compounds by Sorbent Tube/Thermal Desorption/Capillary Gas Chromatography—Part 2: Diffusive Sampling, ISO Copyright Office.
25. (2000). U.S. EPA ISO 16017-1. Indoor, Ambient and Workplace Air—Sampling and Analysis of Volatile Organic Compounds by Sorbent Tube/Thermal Desorption/Capillary Gas Chromatography—Part 1: Pumped Sampling, ISO Copyright Office.
26. The Korea Ministry of Environment (2018). Toluene, Xylene, Methyl ethyl Ketone, Methyl Isobutyl Ketone, Butyl Actate, Stylene and i-Butyl Alcohol-Cold Trap/Thermal Desorption—GC Method (ES09307.a).
27. The Korea Ministry of Environment (2016). Methods for Determination of Hazardous and Volatile Organic Compounds in Ambient Air-Adsorbent Trap Method (ES 01804.2).
28. Measurements of Delays of Gas-Phase Compounds in a Wide Variety of Tubing Materials due to Gas-Wall Interactions10.5194/amt-12-3453-2019 ↗
29. Dunder, T.A., and Leighty, D.A. (1997). Comparison of Thermoelectric and Permeation Dryers for Sulfur Dioxide Removal during Sample Conditioning of Wet Gas Streams, Air and Waste Management Association. No. CONF-970677-.
30. Kim, D.-J. (2018). The Effect of Water Pretreatment Device on Environmental AIR pollutants (O3, SO2, CO) Measurements and Analysis, Konkuk University.
31. A Study of Analytical Method for 4 Legally-designated Compounds [MEK, MIBK, n-Butyl acetate, i-Butyl alcohol] in Ambient Air Using On-line Thermal Desorber with GC/FID