journal article·2019-09-02Open access

Coupling Effect of Space-Arrangement and Wall Thermal Resistance on Indoor Thermal Environment of Passive Solar Single-Family Building in Tibet

Xiaoling Cui, Yangkai Zhang, Guochen Sang, Wenkang Wang, Yiyun Zhu, Lei Zhang

Applied Sciences· Volume 9· Issue 17

Abstract

In areas where solar energy is abundant, such as the Tibetan plateau, passive solar buildings are attracting more and more attention and becoming a popular form of rural building. However, it is often difficult to achieve the satisfactory indoor thermal environment in a local rural passive solar single-family house. In order to improve the indoor thermal environment of passive solar buildings through building design, a systematic study of rural single-family buildings in Tibet was conducted. The basic parameters were investigated on the outdoor thermal environment, space-arrangement, envelope structure, and the indoor thermal environment. The building model considering space-arrangement modes was developed based on the survey data in multi-space passive solar buildings. The general physical and mathematical analysis models of multi-space passive solar buildings were established based on the heat transfer theory. Furthermore, the effects of space-arrangement and exterior wall thermal resistance on indoor air temperature were analyzed by numerical simulation. Results show that the indoor air temperature of the passive solar building is influenced by space-arrangement and wall thermal resistance together. When the space-arrangement of the building model was changed from “north-south through type” (mode a) to “through and separation combination” (mode b) and “north-south separation” (mode c), the indoor air temperature of the living room increased from 8.8 °C to 10.6 °C and 11.6 °C, with increases of 20.5% and 31.8%, respectively. In addition, equally increasing the thermal resistance of exterior walls in different orientations has different effects on the indoor air temperature. In the space-arrangement mode c, comparing with the temperature increment of the living room and bedroom caused by increasing thermal resistance of the south wall and north wall, the temperature increment of the living room caused by increasing thermal resistance of the east/west wall increased by 151.7% and 32.7%, and that of the bedroom increased by 609.1% and 239.1% respectively. This study can provide a reference for the optimal design of passive solar buildings in solar energy abundant areas.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Building Energy and Comfort Optimization · Solar Energy Systems and Technologies · Solar Thermal and Photovoltaic Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Civil Engineering and Architecture, Xi’an University of Technology, Xi′an 710048, China

Funding

National Natural Science Foundation of China

References (37)

Show source-provided references
1. Situation and outlook of solar energy utilization in Tibet, China10.1016/j.rser.2009.03.011 ↗
2. Social and ecological effects of biomass utilization and the willingness to use clean energy in the eastern Qinghai–Tibet plateau10.1016/j.enpol.2012.09.030 ↗
3. Use of rural energy resources and eco-environmental degradation in Tibet
4. Rural household energy consumption and its impacts on eco-environment in Tibet: Taking Taktse county as an example10.1016/j.rser.2007.03.008 ↗
5. Climate change adaptation on the Qinghai–Tibetan Plateau: The importance of solar energy utilization for rural household10.1016/j.rser.2012.10.037 ↗
6. Environmental impacts from the solar energy technologies10.1016/S0301-4215(03)00241-6 ↗
7. Martinopoulos, G. (2016). Solar energy in buildings. Reference Module in Earth Systems and Environmental Sciences, Elsevier.10.1016/B978-0-12-409548-9.09731-1 ↗
8. Vassiliades, C., Kalogirou, S., Michael, A., and Savvides, A. (2019). A Roadmap for the Integration of Active Solar Systems into Buildings. Appl. Sci., 9.10.3390/app9122462 ↗
9. Global solar radiation estimation with sunshine duration in Tibet, China10.1016/j.renene.2011.03.019 ↗
10. A review on photovoltaic/thermal hybrid solar technology10.1016/j.apenergy.2009.06.037 ↗
11. Energetic study of a Trombe wall system under different Tunisian building configurations10.1016/j.enbuild.2014.05.036 ↗
12. Trombe walls: A review of opportunities and challenges in research and development10.1016/j.rser.2012.06.032 ↗
13. Duquesne, M., Palomo Del Barrio, E., and Godin, A. (2019). Nucleation Triggering of Highly Undercooled Xylitol Using an Air Lift Reactor for Seasonal Thermal Energy Storage. Appl. Sci., 9.10.20944/preprints201812.0179.v2 ↗
14. Optimization of passive solar design strategies: A review10.1016/j.rser.2013.04.028 ↗
15. Investigation of Different Window and Wall Materials for Solar Passive Building Design10.1016/j.protcy.2016.05.090 ↗
16. Preparation and characterizations of asphalt/lauric acid blends phase change materials for potential building materials10.1016/j.conbuildmat.2017.05.039 ↗
17. Preparation and thermal energy storage properties of d-Mannitol/expanded graphite composite phase change material10.1016/j.solmat.2016.06.003 ↗
18. Key technological research and application of low energy consumption building design in Tibet
19. Thermal Performance Optimization of Solar Heating Building Envelope in Tibet of China
20. Design and performance of demonstration house with active solar heating in the Qinghai–Tibet Plateau region10.1177/1744259115597443 ↗
21. Effect Analysis of a Passive Solar House in Tibet10.1016/j.aasri.2012.11.098 ↗
22. Indoor Thermal Environments Investigation in Winter of Rural Houses in Yinchuan10.4028/www.scientific.net/AMM.209-211.289 ↗
23. Measureing study of passive solar house for traditional dewlling building in Lhasa area
24. Analysis on building energy performance of Tibetan traditional dwelling in cold rural area of Gannan10.1016/j.enbuild.2015.03.035 ↗
25. Residential thermal environment in cold climates at high altitudes and building energy use implications10.1016/j.enbuild.2013.02.058 ↗
26. Research on Indoor Thermal Environment of Tibetan Rammed Dwellings10.4028/www.scientific.net/AMR.243-249.1995 ↗
27. Ministry of housing and urban-rural development of the People’s Republic of China (2010). Design Standard for Energy Efficiency of Residential Buildings in Severe Cold and Cold Zones.
28. Study of energy efficiency envelope configuration of heating residential buildings in solar radiation zone
29. Energy efficiency and thermal behaviour of attached sunspaces, in the residential architecture in Spain. Summer Conditions10.1016/j.enbuild.2015.09.037 ↗
30. Solar heat gains and operative temperature in attached sunspaces10.1016/j.renene.2011.08.010 ↗
31. The Optimized Matching of Passive Solar Energy supply and Classroom Thermal Demand of Rural Primary and Secondary School in Northwest China10.1016/j.proeng.2015.09.106 ↗
32. Analysis on indoor thermal environment and optimization on design parameters of rural residence10.1016/j.jobe.2017.05.003 ↗
33. Climatic adaptation analysisi of vernacular houses of Lhasa by climate consultant
34. Qisen, Y., and Qingzhu, Z. (1986). Thermal Process of Building, China Building Industry Press.
35. Numerical investigation on the impact of an on-top sunspace passive heating approach for typical rural buildings in northern China10.1016/j.solener.2019.05.013 ↗
36. Ministry of housing and urban-rural development of the People’s Republic of China (2012). Technical Code for Passive Solar Building.
37. Ministry of housing and urban-rural development of the People’s Republic of China (2013). Design standard for energy efficiency of rural residential buildings, Building Envelope Insulation.