journal article·2018-09-29Open access

Registration of Dental Tomographic Volume Data and Scan Surface Data Using Dynamic Segmentation

Keonhwa Jung, Sukwoo Jung, Inseon Hwang, Taeksoo Kim, Minho Chang

Applied Sciences· Volume 8· Issue 10

Abstract

Over recent years, computer-aided design (CAD) has become widely used in the dental industry. In dental CAD applications using both volumetric computed tomography (CT) images and 3D optical scanned surface data, the two data sets need to be registered. Previous works have registered volume data and surface data by segmentation. Volume data can be converted to surface data by segmentation and the registration is achieved by the iterative closest point (ICP) method. However, the segmentation needs human input and the results of registration can be poor depending on the segmented surface. Moreover, if the volume data contains metal artifacts, the segmentation process becomes more complex since post-processing is required to remove the metal artifacts, and initially positioning the registration becomes more challenging. To overcome these limitations, we propose a modified iterative closest point (MICP) process, an automatic segmentation method for volume data and surface data. The proposed method uses a bundle of edge points detected along an intensity profile defined by points and normal of surface data. Using this dynamic segmentation, volume data becomes surface data which can be applied to the ICP method. Experimentally, MICP demonstrates fine results compared to the conventional registration method. In addition, the registration can be completed within 10 s if down sampling is applied.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Radiography and Imaging · Advanced X-ray and CT Imaging · Anatomy and Medical Technology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering, Korea University, Seoul 02841, Korea

References (42)

Show source-provided references
1. Introduction to the DICOM standard10.1007/s003300101100 ↗
2. Quality of DICOM header information for image categorization
3. Mustra, M., Delac, K., and Grgic, M. (2008, January 10–12). Overview of the DICOM standard. Proceedings of the 2008 50th International Symposium ELMAR, Zadar, Croatia.
4. A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results10.1007/s003300050586 ↗
5. Clinical applications of cone-beam computed tomography in dental practice
6. What is Cone-Beam CT and How Does it Work?10.1016/j.cden.2008.05.005 ↗
7. Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography10.1259/dmfr/14140281 ↗
8. Hiller, J.D., and Lipson, H. (2009, January 3–5). STL 2.0: A Proposal for a Universal Multi-Material Additive Manufacturing File Format. Proceedings of the 20th Solid Freeform Fabrication Symposium (SFF), Austin, TX, USA.
9. Structured light using pseudorandom codes10.1109/34.667888 ↗
10. A state of the art in structured light patterns for surface profilometry10.1016/j.patcog.2010.03.004 ↗
11. Accuracy of Linear Measurements Using Cone Beam Computed Tomography in Comparison with Clinical Measurements
12. Accuracy of cone-beam computed tomography at different resolutions assessed on the bony covering of the mandibular anterior teeth10.1016/j.ajodo.2011.06.034 ↗
13. Tolerance within a surgical guide10.1111/j.1600-0501.2009.01836.x ↗
14. Besl, P., and McKay, N. (1992). A Method for Registration of 3-D Shapes. IEEE Trans. Pattern Anal. Mach. Intell.10.1109/34.121791 ↗
15. Range image registration based on 2D synthetic images10.1016/j.cad.2017.08.001 ↗
16. Robust global registration
17. 4-Points Congruent Sets for Robust Pairwise Surface Registration10.1145/1360612.1360684 ↗
18. Three-Dimensional Reconstruction of Cone Beam Computed Tomography Using Splines Interpolation Technique for Dental Application10.1115/1.4033851 ↗
19. Review of portable CT with assessment of a dedicated head CT scanner10.3174/ajnr.A1603 ↗
20. A new minimum variance region growing algorithm for image segmentation10.1016/S0167-8655(97)00012-3 ↗
21. An adaptive region growing method to segment inferior alveolar nerve canal from 3d medical images for dental implant surgery10.3722/cadaps.2008.743-752 ↗
22. Segmentation of teeth in CT volumetric dataset by panoramic projection and variational level set10.1007/s11548-008-0230-9 ↗
23. A level-set based approach for anterior teeth segmentation in cone beam computed tomography images10.1016/j.compbiomed.2014.04.006 ↗
24. Individual tooth segmentation from CT images using level set method with shape and intensity prior10.1016/j.patcog.2010.01.010 ↗
25. Pəvəloiu, I.B., Vasiləţeanu, A., Goga, N., Marin, I., Ilie, C., Ungar, A., and Pətraşcu, I. (2014, January 28–29). 3D dental reconstruction from CBCT data. Proceedings of the 2014 International Symposium on Fundamentals of Electrical Engineering, Bucharest, Romania.10.1109/ISFEE.2014.7050617 ↗
26. Mortaheb, P., Rezaeian, M., and Soltanian-Zadeh, H. (2013, January 10–12). Automatic dental CT image segmentation using mean shift algorithm. Proceedings of the 2013 8th Iranian Conference on Machine Vision and Image Processing (MVIP), Zanjan, Iran.10.1109/IranianMVIP.2013.6779962 ↗
27. Dentalmaps: Automatic dental delineation for radiotherapy planning in head-and-neck cancer10.1016/j.ijrobp.2011.03.035 ↗
28. Artefacts in CBCT: A review10.1259/dmfr/30642039 ↗
29. Iterative Deblurrinf for CT metal artifact reduction10.1109/42.538943 ↗
30. A pragmatic approach to metal artifact reduction in CT: Merging of metal artifact reduced images10.1007/s00330-004-2263-y ↗
31. Quantitative CT for determination of bone mineral density: A review10.1148/radiology.166.2.3275985 ↗
32. Bone classification: An objective scale of bone density using the computerized tomography scan10.1034/j.1600-0501.2001.012001079.x ↗
33. Determination of bone quality of 372 implant recipient sites using hounsfield unit from computerized tomography: A clinical study10.1111/j.1708-8208.2008.00085.x ↗
34. Evaluation of on-board imager cone beam CT hounsfield units for treatment planning using rigid image registration10.4103/0973-1482.146087 ↗
35. Comments on “Digital Step Edges from Zero Crossings of Second Directional Derivatives”10.1109/TPAMI.1985.4767628 ↗
36. Sorkine, O., and Rabinovich, M. (2009, February 24). Least-Squares Rigid Motion Using SVD. Available online: http://www.igl.ethz.ch/projects/ARAP/svd_rot.pdf.
37. An intuitive framework for real-time freeform modeling10.1145/1015706.1015772 ↗
38. Multiresolution shape deformations for meshes with dynamic vertex connectivity
39. Gelfand, N., Ikemoto, L., Rusinkiewicz, S., and Levoy, M. (2003, January 6–10). Geometrically stable sampling for the ICP algorithm. Proceedings of the Fourth International Conference on 3-D Digital Imaging and Modeling, Banff, AB, Canada.
40. The medical imaging interaction toolkit10.1016/j.media.2005.04.005 ↗
41. Cignoni, P., Corsini, M., and Ranzuglia, G. (2008, January 2–4). MeshLab: An Open-Source Mesh Processing Tool. Proceedings of the Eurographics Italian Chapter Conference, Salerno, Italy.
42. Consistency and precision of landmark identification in three-dimensional cone beam computed tomography scans10.1093/ejo/cjq144 ↗