Friction Factor Correlation for Regenerator Working in a Travelling-Wave Thermoacoustic System
Source abstract
Abstract
Regenerator is a porous solid structure which is important in the travelling-wave thermoacoustic system. It provides the necessary contact surface and thermal capacity for the working gas to undergo a thermodynamic cycle under acoustic oscillatory flow conditions. However, it also creates a pressure drop that could degrade the overall system performance. Ideally, in a travelling-wave system, the phase angle between oscillating pressure and velocity in the regenerator should be zero, or as close to zero as possible. In this study, the hydrodynamic condition of a regenerator has been investigated both experimentally (in a purpose-built rig providing a travelling-wave phasing) and numerically. A two-dimensional ANSYS FLUENT CFD model, capturing the important features of the experimental conditions, has been developed. The findings suggest that a steady-state correlation, commonly used in designing thermoacoustic systems, is applicable provided that the travelling-wave phase angle is maintained. However, for coarse mesh regenerators, the results show interesting “phase shifting” phenomena, which may limit the correlation validity. Current experimental and CFD studies are important for predicting the viscous losses in future models of thermoacoustic systems.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Thermodynamic Systems and Engines · Spacecraft and Cryogenic Technologies · Thermodynamic and Exergetic Analyses of Power and Cooling Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Centre for Advanced Research on Energy, Faculty of Mechanical Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka, Malaysia
Faculty of Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK
Funding
Royal Society · Ministry of Education, Malaysia and Universiti Teknikal Malaysia Melaka · EPSRC Advanced Research Fellowship
References (26)
Show source-provided references
1. Rayleigh (1878). The explanation of certain acoustical phenomena. Nature, 319–321.10.1038/018319a0 ↗
2. A thermoacoustic-Stirling heat engine: Detailed study10.1121/1.429343 ↗
3. Impact of acoustic impedance and channel dimensions on the power output capacity of the regenerators in travelling-wave thermoacoustic engines10.1016/j.enconman.2009.09.032 ↗
4. Bejan, A., Dincer, I., Lorente, S., Miguel, A.F., and Reis, A.H. (2004). Porous and Complex Flow Structures in Modern Technologies, Springer.10.1007/978-1-4757-4221-3 ↗
5. Investigation on the pressure drop characteristic of cryoocooler regenerators under oscillating flow and pulsating pressure conditions10.1016/j.cryogenics.2003.11.006 ↗
6. Gedeon, D., and Wood, J.G. (1996). Oscillating-Flow Regenerator Test Rig: Hardware and Theory with Derived Correlations for Screens and Felt.
7. Simple Harmonic Analysis of Regenerators10.2514/3.842 ↗
8. Kays, W.M., and London, A.L. (1964). Compact Heat Exchangers, McGraw-Hill.
9. Design environment for low-amplitude thermoacoustic engines10.1121/1.409938 ↗
10. Experimental study of the oscillating flow characteristics for a regenerator in a pulse tube cryocooler10.1016/S0011-2275(98)00037-X ↗
11. Novel flow analysis of regenerator under oscillating flow with pulsating pressure10.1016/j.cryogenics.2005.01.001 ↗
12. Characterization of the frictional losses and heat transfer of oscillatory viscous flow through wire mesh regenerators10.1016/j.aej.2015.06.001 ↗
13. Investigation on phase shifter of a 10 W/70 K inertance pulse tube refrigerator10.1016/j.ijrefrig.2016.10.021 ↗
14. Vafai, K. (2005). Handbook of Porous Media, Taylor and Francis Group. [2nd ed.].10.1201/9780415876384 ↗
15. On Pressure-Velocity Correlation of Steady and Oscillating Flows in Regenerators Made of Wire Screens10.1115/1.2822010 ↗
16. Thermal dispersion in a porous medium10.1016/0017-9310(90)90015-M ↗
17. Oscillatory pressure drops through a woven-screen packed column subjected to a cyclic flow10.1016/0011-2275(96)81103-9 ↗
18. Oscillatory flow in microporous media applied in pulse-tube and Stirling-cycle cryocooler regenerators10.1016/j.expthermflusci.2008.02.008 ↗
19. Anisotropy steady-flow hydrodynamic parameters of microporous media applied to pulse tube and Stirling cryocooler regenerators10.1016/j.cryogenics.2008.01.002 ↗
20. Hydrodynamic parameters of mesh fillers relevant to miniature regenerative cryocoolers10.1016/j.cryogenics.2010.01.017 ↗
21. Numerical analysis on pressure drop and heat transfer performance of mesh regenerators used in cryocoolers10.1016/j.cryogenics.2009.07.003 ↗
22. Use of inertance in orifice pulse tube refrigerators10.1016/S0011-2275(96)00107-5 ↗
23. A transfer-matrix approach for estimating the characteristic impedance and wave number of limp and rigid porous materials10.1121/1.428404 ↗
24. Experimental evaluation of the acoustic properties of stacked-screen regenerators10.1121/1.3056552 ↗
25. Swift, G.W. (2002). Thermoacoustics: A Unifying Perspective for Some Engines and Refrigerators, Acoustical Society of America Publications.10.1121/1.1561492 ↗
26. ANSYS FLUENT 13.0 (User Manual, 2010). User Manual.