Seismic Performance Test of Double-Row Reinforced Ceramsite Concrete Composite Wall Panels with Cores
Source abstract
Abstract
The research objective of this study was the seismic performance of double-row reinforced ceramsite concrete sandwich wall panels. The feasibility of upgrading a new wall panel from a non-load-bearing partition wall to a load-bearing seismic wall was examined by conducting cyclic load tests on five wall panel specimens. The test piece was a sandwich thermal insulation structure that could achieve a good protection distance between the thermal insulation material and the fire source so that the fire prevention problem could be solved. At the same time, the problem of easy fall-off of the insulation system was also solved. The specimens were divided into three groups, including three double-row reinforced ceramsite concrete sandwich wall panels with different dosages of alkali-resistant glass fiber, a double-row reinforced ordinary concrete sandwich wall panel, and a solid concrete ceramic wallboard. The effects of different dosages of alkali-resistant glass fiber, construction forms, and bearing side plate materials on the seismic performance of the sandwich wall panels were investigated separately for the specimens. From the analysis of the specimen results (damage characteristics, hysteresis curves, energy dissipation capacity, bearing capacity, ductility, longitudinal reinforcement strain, and stiffness degradation), it could be seen that among the five types of wallboard, the double-row reinforced ceramsite concrete sandwich wall panel with 0.3% fiber content had the best ductility and energy dissipation capacity. Adding fiber could solve or improve the problem of the low ultimate bearing capacity of ceramsite concrete as the wallboard’s bearing material. Compared with the same size solid ordinary concrete wallboard, the bearing capacity of the double-row reinforced ceramic concrete sandwich panel was slightly reduced. However, the additional seismic performance indexes were relatively superior. Through the analysis of the test results, it was shown that, when considering the thermal performance and seismic capacity, the new wall panel had good prospects for engineering applications.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Civil Engineering and Architecture, Henan University, Kaifeng 475004, China
College of Water Conservancy & Engineering, Zhengzhou University, Zhengzhou 450001, China
References (30)
Show source-provided references
1. Experimental performance of intermittent space heating with different terminals in a self-thermal insulation building
2. Tsinghua University Building Energy Conservation Research Center (2018). Research Report on Annual Development of Building Energy Efficiency in China, Chinese Building Industry Press.
3. Analysis of factors affecting energy consumption of typical residential buildings in northern new countryside based on energy consumption simulation
4. Experimental testing of a low-damage post-tensioned C-shaped CLT core-wall10.1061/(ASCE)ST.1943-541X.0002926 ↗
5. Full scale testing of precast concrete sandwich panels
6. Ferrocement encased lightweight aerated concrete: A novel approach to produce sandwich composite10.1016/j.matlet.2007.01.039 ↗
7. Thermal conductivity of newspaper sandwiched aerated lightweight concrete panel10.1016/j.enbuild.2010.08.026 ↗
8. Micro-pore structure characteristics and macro-mechanical properties of PP fibre reinforced coal gangue ceramsite concrete
9. Research progress of ceramsite concrete
10. Investigation of the high-temperature resistance of sludge ceramsite concrete with recycled fine aggregates and GGBS and its application in hollow blocks10.1016/j.jobe.2020.101954 ↗
11. Experimental study on deformation and failure characteristics of ceramsite concrete block under typical loading mode after freeze-thaw cycles
12. Chen, Y.M. (2016). Experimental Research on the Mechanical Properties of Ceramsite Concrete Core Self-Insulation Wallboard. [Master’s Thesis, Henan University].
13. Geng, Z.H. (2016). Analysis of Ceramsite Concrete Insulation Sandwich Wall under Low Cyclic Loading. [Master’s Thesis, Henan University].
14. Performance analysis of ceramsite concrete sandwich insulation composite wallboard
15. Cyclic response of masonry infilled RC frames: Experimental results and simplified modeling10.1016/j.soildyn.2014.06.016 ↗
16. Practice-oriented probabilistic seismic performance assessment of infilled frames with consideration of shear failure of columns10.1002/eqe.2275 ↗
17. Ferraioli, M., and Lavino, A. (2020). Irregularity effects of masonry infills on nonlinear seismic behaviour of RC buildings. Math. Probl. Eng.10.1155/2020/4086320 ↗
18. Nonlinear seismic responses and lateral force transfer mechanisms of RC frames with different infill configurations10.1016/j.engstruct.2015.02.031 ↗
19. Ma, S.C., Bao, P., and Jiang, N. (2020). Experimental study of gypsum-concrete dense-column composite boards with external thermal insulation systems. Appl. Sci., 10.10.3390/app10061976 ↗
20. Experimental investigation on the seismic behavior of a new-type composite interior wallboard10.1617/s11527-016-0845-1 ↗
21. Load bearing sandwich timber walls with plywood faces and bamboo core10.1016/j.istruc.2020.08.020 ↗
22. Seismic performance of cold formed steel walls sheathed by fibre-cement board panels10.1016/j.jcsr.2015.01.003 ↗
23. Seismic analysis of multi-storey timber buildings braced with a CLT core and perimeter shear-walls10.1007/s10518-018-0467-9 ↗
24. Energy performance of existing residential buildings in Europe: A novel approach combining energy with seismic retrofitting10.1016/j.enbuild.2020.110024 ↗
25. Experimental analysis on mechanical properties of alkali resistant glass fiber reinforced ceramsite concrete
26. (2015). JGJ/T101-2015 Specification of Seismic Test of Buildings, Chinese Building Industry Press.
27. (1997). JGJ101-96 Specification of Testing Methods for Earthquake Resistant Building, Chinese Building Industry Press.
28. Seismic experimental study on new-type composite exterior wallboard with integrated structural function and insulation10.3390/ma8063732 ↗
29. The influence rule of horizontal steel bar connection on seismic behavior of assembled composite shear wall joints
30. Experimental study on cyclic behavior of post-tensioned segmental retaining walls (PSRWs)10.1016/j.engstruct.2020.111619 ↗