journal article·2020-06-24Open access

Identification of Surgical Plan for Syndesmotic Fixation Procedure Based on Finite Element Method

Tae Sik Goh, Beop-Yong Lim, Jung Sub Lee, Chi-Seung Lee

Applied Sciences· Volume 10· Issue 12

Abstract

Syndesmosis injuries account for approximately 20% of ankle fractures that require surgery. Although multiple surgical options are available, all of them are based on metal screws. Serious complications that arise when applying metal screws include screw loosening or breakage. To prevent such complications, we applied a simulation method using a finite element (FE) analysis. We created a 3D FE model of an ankle joint and conducted an FE analysis focusing on syndesmosis in terms of the level, material, and diameter of the syndesmotic screw and the number of penetrated cortical bones. The magnitude and direction of the force applied to the tibia in the midstance state were considered for simulating the model. The maximum von-Mises stress and syndesmosis widening were analyzed in terms of different biomechanical parameters. We identified the characteristics of the most biomechanically stable syndesmotic screw and its fixation point on the basis of the two parameters. We demonstrated that the ideal syndesmotic screw fixation should be fixed at a level 20 to 25 mm above the ankle using a 4.5 mm titanium screw.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Foot and Ankle Surgery · Bone fractures and treatments · Orthopedic Surgery and Rehabilitation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthopaedic Surgery, Pusan National University Hospital, Busan 49241, Korea

Biomedical Research Institute, Pusan National University Hospital, Busan 49241, Korea

Department of Biomedical Engineering, Graduate School, Pusan National University, Busan 49241, Korea

University Research Park of Pusan National University, Busan 49241, Korea

Department of Convergence Medicine, School of Medicine, Pusan National University, Busan 49241, Korea

Department of Biomedical Engineering, School of Medicine, Pusan National University, Busan 49241, Korea

Funding

National Research Foundation of Korea

References (33)

Show source-provided references
1. Complications of syndesmotic screw removal10.3113/FAI.2011.1040 ↗
2. Fractures of the ankle: II. Combined experimental-surgical and experimental-roentgenologic investigations10.1001/archsurg.1950.01250010980011 ↗
3. Injuries to the distal lower extremity syndesmosis10.5435/00124635-199705000-00006 ↗
4. Syndesmosis screws: How many, what diameter, where and should they be removed? A literature review10.1016/j.injury.2014.05.003 ↗
5. Outcome after fixation of ankle fractures with an injury to the syndesmosis
6. Syndesmotic screw placement: A biomechanical analysis10.1177/107110079701800503 ↗
7. Operative aspects of the syndesmotic screw: Review of current concepts10.1016/j.injury.2007.11.425 ↗
8. Screw fixation of the syndesmosis: A cadaver model comparing stainless steel and titanium screws and three and four cortical fixation10.1016/j.injury.2004.05.024 ↗
9. Three-dimensional finite element analysis used to compare six different methods of syndesmosis fixation with 3.5- or 4.5-mm titanium screws: A biomechanical study10.7547/1030174 ↗
10. Liu, Q., Zhang, K., Zhuang, Y., Li, Z., Yu, B., and Pei, G. (2013). Analysis of the stress and displacement distribution of inferior tibiofibular syndesmosis injuries repaired with screw fixation: A finite element study. PLoS ONE, 8.10.1371/journal.pone.0080236 ↗
11. Biomechanical Evaluation of Syndesmotic Screw Position: A Finite-Element Analysis10.1097/BOT.0b013e3182a6df0a ↗
12. Effects of inferior tibiofibular syndesmosis injury and screw stabilization on motion of the ankle: A finite element study10.1007/s00167-014-3320-y ↗
13. Biomechanical characteristics of human ankle ligaments10.1177/107110078500600202 ↗
14. Tensile properties of the interosseous membrane of the human forearm10.1002/jor.1100140525 ↗
15. Finite element analysis of the implanted proximal tibia: A relationship between the initial cancellous bone stresses and implant migration10.1016/S0021-9290(98)00022-0 ↗
16. Full-range stress–strain curves for stainless steel alloys10.1016/S0143-974X(02)00018-4 ↗
17. Kemper, A., McNally, C., Kennedy, E., Manoogian, S., and Duma, S. (2007, January 18–21). The material properties of human tibia cortical bone in tension and compression: Implications for the tibia index. Proceedings of the 20th Enhanced Safety of Vehicles Conference, Lyon, France.
18. Biomechanical analysis of tibia-double threaded screw fixation
19. Finite element analysis of the stress concentration in pronation-abduction ankle joint injuries
20. Conway, J.B., Stentz, R., and Berling, J. (1975). Fatigue, Tensile, and Relaxation Behavior of Stainless Steels, Mar-Test, Inc.10.2172/4239699 ↗
21. Surface chemical treatment of ultrafine-grained Ti–6Al–7Nb alloy processed by severe plastic deformation10.1016/j.jallcom.2014.11.115 ↗
22. Koistinen, A. (2012). Improvement of The Orthopaedic Bone Screws by DLC Coatings, Academic Dissertation, University of Eastern Finland.
23. Piper, A.T. (2016). Modelling Cancellous Bone Screw Performance Using Finite Element Models. [Ph.D. Thesis, Brunel University].
24. Prediction of three-dimensional contact stress and ligament tension in the ankle during stance determined from computational modeling10.3113/FAI-2009-0177 ↗
25. Stress distribution of the foot during mid-stance to push-off in barefoot gait: A 3-D finite element analysis10.1016/S0268-0033(01)00047-X ↗
26. Finite element analysis of a total ankle replacement during the stance phase of gait10.1016/j.jbiomech.2005.04.010 ↗
27. Finite element analysis of nonanatomic tenodesis reconstruction methods of combined anterior talofibular ligament and calcaneofibular ligament deficiency10.3113/FAI.2011.1000 ↗
28. Biomechanical evaluation of tenodesis reconstruction in ankle with deltoid ligament deficiency: A finite element analysis10.1007/s00167-011-1762-z ↗
29. Comparison of tricortical screw fixation versus a modified suture construct for fixation of ankle syndesmosis injury: A biomechanical study10.1097/00005131-199901000-00009 ↗
30. Finite element modelling of the fracture behaviour of surface treated Ti-6Al-4V alloy
31. Biomechanical comparison of syndesmosis fixation with 3.5- and 4.5-millimeter stainless steel screws10.1177/107110070002100904 ↗
32. Syndesmosis fixation: Analysis of shear stress via axial load on 3.5-mm and 4.5-mm quadricortical syndesmotic screws10.1053/j.jfas.2005.12.004 ↗
33. Syndesmosis fixation: A comparison of three and four cortices of screw fixation without hardware removal10.1177/107110070602700801 ↗