Cyclic Behavior of Anchored Blind-Bolted Extended End-Plate Joints to CFST Columns
Source abstract
Abstract
As the square steel tube in the tension zone is always the weakest part of moment-resisting joints, modified blind bolts (Hollo-Bolts) and a locally strengthened steel tube in the panel zone were adopted to enhance the joint performance. Cyclic loading tests were carried out on eight anchored blind-bolted extended end-plate joints between square concrete-filled steel tube (CFST) columns and steel beams. The test parameters included the end-plate thickness, steel tube wall thickness, beam section size, local strengthening connection method, blind bolt anchorage method, and stiffeners. The failure mode, hysteretic behavior, stiffness, strength, ductility, strength degradation, stiffness degradation, and energy dissipation capacity of the joints were studied and analyzed. The test results showed that the application of anchored blind bolts and a locally strengthened steel tube can fully utilize the bolt strength and significantly improve the joint performance, especially in terms of strength and strength degradation. The test observations revealed three typical failure modes for the joints, and the failure mode depended on the weakest component. In addition, the local reinforcement of C-channel and change in the anchorage method had a limited effect on the initial stiffness. Greater end-plate thickness and the use of stiffeners significantly increased the joint stiffness and decreased the rate of stiffness degradation. The use of stiffeners also significantly enhanced the ductility and energy dissipation by moving plastic hinge outward from the joints. Finally, finite element analysis (FEA) models were developed and validated against the experimental results, and the stress distribution and force transfer pattern were investigated.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete · Fire effects on concrete materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510641, China
State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510641, China
School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou 510006, China
References (32)
Show source-provided references
1. Developments and advanced applications of concrete-filled steel tubular (CFST) structures: Members10.1016/j.jcsr.2014.04.016 ↗
2. Seismic behavior and modeling of high-strength composite concrete-filled steel tube (CFT) beam-columns10.1016/S0143-974X(01)00099-2 ↗
3. Noncompact and slender rectangular CFT members: Experimental database, analysis, and design10.1016/j.jcsr.2014.06.004 ↗
4. Research on Compression Behavior of Square Thin-Walled CFST Columns with Steel-Bar Stiffeners10.3390/app8091602 ↗
5. Cyclic behaviour of novel blind bolted joints with different stiffening elements10.1016/j.tws.2016.01.007 ↗
6. Behaviour of flush end plate joints to concrete-filled steel tubular columns10.1016/j.jcsr.2008.10.010 ↗
7. Blind bolted moment connection to sides of hollow section columns10.1016/j.jcsr.2011.06.007 ↗
8. Blind bolted moment connection to unfilled hollow section columns using extended T-stub with back face support10.1016/j.engstruct.2011.02.008 ↗
9. Behaviour of combined channel/angle connections to tubular columns under monotonic and cyclic loading10.1016/j.engstruct.2010.02.008 ↗
10. Gardner, A., and Goldsworthy, H. (1999). Moment-resisting connections for composite frames. Mechanics of Structures and Materials Conference, CRC Press.
11. Experimental investigation of the stiffness of critical components in a moment-resisting composite connection10.1016/j.jcsr.2004.11.004 ↗
12. Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns10.12989/sem.2006.24.4.463 ↗
13. Experimental and Numerical Investigation of the Tensile Behavior of Blind-Bolted T-Stub Connections to Concrete-Filled Circular Columns10.1061/(ASCE)0733-9445(2008)134:2(198) ↗
14. Performance of CFTST column to steel beam joints with blind bolts under cyclic loading10.1016/j.tws.2012.06.018 ↗
15. Structural performance of blind bolted end plate joints to concrete-filled thin-walled steel tubular columns10.1016/j.tws.2012.07.006 ↗
16. Tizani, W., and Ridley, E. (2003). The Performance of a New Blind-Bolt for Moment-Resisting Connections, Taylor & Francis.
17. Experimental behaviour of a novel anchored blind-bolt in tension10.1016/j.engstruct.2012.12.023 ↗
18. Tensile behaviour of anchored blind bolts in concrete filled square hollow sections10.1617/s11527-015-0592-8 ↗
19. Tensile Behavior of Groups of Anchored Blind Bolts within Concrete-Filled Steel Square Hollow Sections10.1061/(ASCE)ST.1943-541X.0001388 ↗
20. Rotational stiffness of a blind-bolted connection to concrete-filled tubes using modified Hollo-bolt10.1016/j.jcsr.2012.09.024 ↗
21. Hysteretic performance of a new blind bolted connection to concrete filled columns under cyclic loading: An experimental investigation10.1016/j.engstruct.2012.08.020 ↗
22. (2011). Technical Specification for Concrete Structures of Building, China Architecture and Building Press. JGJ3-2010.
23. Peter Clark, K.F.H.K. (1997). Protocol for Fabrication, Inspection, Testing, and Documentation of Beam-Column Connection Tests and Other Experimental Specimens, SAC Joint Venture. Rep. No. SAC/BD-97/02.
24. Experimental study on seismic behavior of steel-reinforced concrete square column and steel beam joint with bolted end-plate
25. Experimental study on blind bolted connections to concrete-filled stainless steel columns10.1016/j.jcsr.2016.10.016 ↗
26. (2005). Eurocode 3: Design of Steel Structures-Part 1–8. Design of Joints, European Committee for Standardization. EN 1993–1-8.
27. (2011). Eurocode 8: Design of Structures for Earthquake Resistance-Part 1: General Rules, Seismic Actions, British Standard Institute. BS EN 1998-1:2004.
28. (2000). Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings, Federal Emergency Management Agency. FEMA-350.
29. Seismic response of extended end plate joints to concrete-filled steel tubular columns10.1016/j.engstruct.2013.01.001 ↗
30. (2010). Seismic Provisions for Structural Steel Buildings, American Institute of Steel Construction. ANSI/AISC 341-10.
31. Behavior of eight-bolt large capacity endplate connections10.1016/S0045-7949(99)00218-7 ↗
32. Tests and calculations for hollow structural steel (HSS) stub columns filled with self-consolidating concrete (SCC)10.1016/j.jcsr.2005.01.004 ↗