Comparison of Feature Vector Compositions to Enhance the Performance of NIRS-BCI-Triggered Robotic Hand Orthosis for Post-Stroke Motor Recovery
Source abstract
Abstract
Recently, brain–computer interfaces, combined with feedback systems and goal-oriented training, have been investigated for their capacity to promote functional recovery after stroke. Accordingly, we developed a brain–computer interface-triggered robotic hand orthosis that assists hand-closing and hand-opening for post-stroke patients without sufficient motor output. In this system, near-infrared spectroscopy is used to monitor the affected motor cortex, and a linear discriminant analysis-based binary classifier estimates hand posture. The estimated posture then wirelessly triggers the robotic hand orthosis. For better performance of the brain–computer interface, we tested feature windows of different lengths and varying feature vector compositions with motor execution data from seven neurologically intact participants. The interaction between a feature window and a delay in the hemodynamic response significantly affected both classification accuracy (Matthew Correlation Coefficient) and detection latency. The ‘preserving channels’ feature vector was able to increase accuracy by 13.14% and decrease latency by 29.48%, relative to averaging. Oxyhemoglobin combined with deoxyhemoglobin improved accuracy by 3.71% and decreased latency by 6.01% relative to oxyhemoglobin alone. Thus, the best classification performance resulted in an accuracy of 0.7154 and a latency of 2.8515 s. The hand rehabilitation system was successfully implemented using this feature vector composition, which yielded better classification performance.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: EEG and Brain-Computer Interfaces · Neuroscience and Neural Engineering · Muscle activation and electromyography studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, Faculty of Engineering, Kyushu University, Fukuoka 819-0395, Japan
Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka 812-8582, Japan
Kitakyushu Chuo Hospital, Kitakyushu, Fukuoka 802-0084, Japan
Funding
The Center for Clinical and Translational Research of Kyushu University · Japan Agency for Medical Research and Development
References (31)
Show source-provided references
1. Effect of Constraint-Induced Movement Therapy on Upper Extremity Function 3 to 9 Months After Stroke: The EXCITE Randomized Clinical Trial10.1001/jama.296.17.2095 ↗
2. Motor Learning Elicited by Voluntary Drive10.1093/brain/awg079 ↗
3. Quality of Life after Stroke: The Importance of a Good Recovery10.1159/000200461 ↗
4. Brain-Computer Interface Technology: A Review of the First International Meeting10.1109/TRE.2000.847807 ↗
5. Brain-Computer Interface in Stroke: A Review of Progress10.1177/155005941104200410 ↗
6. Brain–Machine Interfaces in Neurorehabilitation of Stroke10.1016/j.nbd.2014.11.025 ↗
7. Functional Near-Infrared Spectroscopy: Current Status and Future Prospects10.1117/1.2804911 ↗
8. Neurovascular Regulation in the Normal Brain and in Alzheimer’s Disease10.1038/nrn1387 ↗
9. Coupling of Brain Activity and Cerebral Blood Flow: Basis of Functional Neuroimaging
10. Naseer, N., and Hong, K.-S. (2015). FNIRS-Based Brain-Computer Interfaces: A Review. Front. Hum. Neurosci, 9.10.3389/fnhum.2015.00003 ↗
11. Brain–Computer Interfaces for Communication and Control10.1016/S1388-2457(02)00057-3 ↗
12. Near-Infrared Spectroscopy–Mediated Neurofeedback Enhances Efficacy of Motor Imagery–Based Training in Poststroke Victims: A Pilot Study10.1161/STROKEAHA.111.674507 ↗
13. Lee, J., Mukae, N., Arata, J., Iwata, H., Iramina, K., Iihara, K., and Hashizume, M. (2017, January 17–20). A Multichannel-near-Infrared-Spectroscopy-Triggered Robotic Hand Rehabilitation System for Stroke Patients. Proceedings of the 2017 IEEE International Conference on Rehabilitation Robotics (ICORR), London, UK.10.1109/ICORR.2017.8009239 ↗
14. Arata, J., Ohmoto, K., Gassert, R., Lambercy, O., Fujimoto, H., and Wada, I. (2013, January 6–10). A New Hand Exoskeleton Device for Rehabilitation Using a Three-Layered Sliding Spring Mechanism. Proceedings of the 2013 IEEE International Conference on Robotics and Automation, Karlsruhe, Germany.10.1109/ICRA.2013.6631126 ↗
15. Eigenvector-Based Spatial Filtering for Reduction of Physiological Interference in Diffuse Optical Imaging10.1117/1.1852552 ↗
16. Cui, X., Bray, S., and Reiss, A.L. (2010). Speeded Near Infrared Spectroscopy (NIRS) Response Detection. PLoS ONE, 5.10.1371/journal.pone.0015474 ↗
17. Durantin, G., Scannella, S., Gateau, T., Delorme, A., and Dehais, F. (2014, January 26–30). Moving Average Convergence Divergence Filter Preprocessing for Real-Time Event-Related Peak Activity Onset Detection: Application to FNIRS Signals. Proceedings of the 2014 IEEE 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL, USA.10.1109/EMBC.2014.6944032 ↗
18. Gateau, T., Durantin, G., Lancelot, F., Scannella, S., and Dehais, F. (2015). Real-Time State Estimation in a Flight Simulator Using FNIRS. PLoS ONE, 10.10.1371/journal.pone.0121279 ↗
19. False Positives and False Negatives in Functional Near-Infrared Spectroscopy: Issues, Challenges, and the Way Forward10.1117/1.NPh.3.3.031405 ↗
20. Lyons, R.G. (2011). Understanding Digital Signal Processing, Prentice Hall.
21. Theodoridis, S., and Koutroumbas, K. (2008). Pattern Recognition, Elsevier/Acad. Press. [4th ed.].
22. Enhanced Performance by a Hybrid NIRS–EEG Brain Computer Interface10.1016/j.neuroimage.2011.07.084 ↗
23. Performance Enhancement of a Brain-Computer Interface Using High-Density Multi-Distance NIRS10.1038/s41598-017-16639-0 ↗
24. Think to Move: A Neuromagnetic Brain-Computer Interface (BCI) System for Chronic Stroke10.1161/STROKEAHA.107.505313 ↗
25. ERD-Based Online Brain–Machine Interfaces (BMI) in the Context of Neurorehabilitation: Optimizing BMI Learning and Performance10.1109/TNSRE.2011.2166809 ↗
26. Brain-Machine Interface in Chronic Stroke Rehabilitation: A Controlled Study10.1002/ana.23879 ↗
27. Ono, T., Shindo, K., Kawashima, K., Ota, N., Ito, M., Ota, T., Mukaino, M., Fujiwara, T., Kimura, A., and Liu, M. (2014). Brain-Computer Interface with Somatosensory Feedback Improves Functional Recovery from Severe Hemiplegia Due to Chronic Stroke. Front. Neuroeng., 7.10.3389/fneng.2014.00019 ↗
28. Effects of Cerebral Ischemia on Evoked Cerebral Blood Oxygenation Responses and BOLD Contrast Functional MRI in Stroke Patients10.1161/01.STR.0000239698.50656.3b ↗
29. Influence of Skin Blood Flow on Near-Infrared Spectroscopy Signals Measured on the Forehead during a Verbal Fluency Task10.1016/j.neuroimage.2011.05.012 ↗
30. Evaluation of the Cerebral Hemodynamic Response to Rhythmic Handgrip10.1152/jappl.2000.88.6.2205 ↗
31. Two-Detector Corrected Near Infrared Spectroscopy (C-NIRS) Detects Hemodynamic Activation Responses More Robustly than Single-Detector NIRS10.1016/j.neuroimage.2011.01.043 ↗