journal article·2017-09-01Open access

Properties of Aged GFRP Reinforcement Grids Related to Fatigue Life and Alkaline Environment

Francesco Micelli, Marco Corradi, Maria Aiello, Antonio Borri

Applied Sciences· Volume 7· Issue 9

Abstract

In recent years, even if Fiber Reinforced Polymer (FRP) composites have been widely used for strengthening of civil buildings, a new generation of materials has been studied and proposed for historical masonry construction. These buildings, mainly made of stone work, are common in many areas of Europe and Asia and recent earthquakes has been the cause of many catastrophic failures. The brittleness of unreinforced historic masonry can be considerably reduced using new retrofitting lighter-weight materials such FRP, even if limitations were evidenced due to material and mechanical compatibility with poor substrates. Thus, fibrous reinforcements were used as long fibres incorporated into a cement or lime matrix, which better match with the properties of ancient masonry. The use of low strength fibers such as glass and basalt, respect to carbon, in presence of an alkaline matrix brought out durability issues, due to the chemical vulnerability of common glass and basalt fibres. The objective of this research is to explore the effects of selected aqueous environments and fatigue loading on the mechanical and physical properties of composite grids, made of E-CR (Electrical/Chemical Resistance) glass fibers and epoxy-vinylester resin, used as tensile reinforcement in new composite reinforced mortar systems. Glass-fiber-reinforced polymer (GFRP) coupons were subjected to tensile testing and a severe protocol of durability tests, including alkaline environment and fatigue tensile loads. Accelerated ageing tests were used to simulate long-term degradation in terms of chemical attack and consequent reduction of tensile strength. The ageing protocol consisted of immersion at 40 °C in alkaline bath made by deionized water and Ca(OH)2, 0.16% in weight, solution for 30 days. GFRP specimens aged and unaged were also tested under tensile fatigue cycles up to 1,000,000 cycles and a nominal frequency of 7.5 Hz. After this severe conditioning the tests indicate a good tensile strength retention of the GFRP in absence of fatigue loads, while a significant loss in fatigue life was experienced when both alkaline exposure and fatigue loads were applied.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Masonry and Concrete Structural Analysis · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Innovation Engineering, University of Salento, Via per Monteroni, 73100 Lecce, Italy

Department of Engineering, Perugia University, Via Duranti, 92, 06125 Perugia, Italy

References (34)

Show source-provided references
1. URM walls strengthened with fabric-reinforced cementitious matrix composite subjected to diagonal compression
2. Experimental and numerical study on the shear behavior of stone masonry walls strengthened with GFRP reinforced mortar coating and steel-cord reinforced repointing10.1016/j.engstruct.2015.02.024 ↗
3. Shear strengthening of wall panels through jacketing with cement mortar reinforced by GFRP grids10.1016/j.compositesb.2014.03.022 ↗
4. Behavior of thin masonry arches repaired using composite materials10.1016/j.compositesb.2015.09.008 ↗
5. Round robin test for composite-to-brick shear bond characterization10.1617/s11527-012-9883-5 ↗
6. FRP—Brick masonry bond degradation under hygrothermal conditions10.1016/j.compstruct.2016.03.037 ↗
7. Moisture-induced degradation of interfacial bond in FRP-strengthened masonry10.1016/j.compositesb.2015.10.022 ↗
8. Bond between TRM versus FRP composites and concrete at high temperatures10.1016/j.compositesb.2017.05.064 ↗
9. Effect of thermo-hygrometric exposure on FRP, natural stone and their adhesive interface10.1016/j.compositesb.2015.05.041 ↗
10. Application of digital image correlation in investigating the bond between FRP and masonry10.1016/j.compstruct.2013.06.024 ↗
11. Effect of wet-dry cycles on the bond behaviour of concrete elements strengthened with NSM CFRP laminate strips10.1016/j.compstruct.2015.05.053 ↗
12. Characteristics of fatigue crack growth in GFRP laminates10.1016/S0142-1123(01)00084-6 ↗
13. Fatigue behavior of adhesively connected pultruded GFRP profiles10.1016/j.compstruct.2003.10.008 ↗
14. Fatigue analysis of unidirectional GFRP composites under combined bending and torsional loads
15. Residual strength of GFRP at high-cycle fatigue10.1007/BF02329325 ↗
16. Tension—Tension axial fatigue of E-glass fibre reinforced polymeric composites: Fatigue life diagram10.1016/S0950-0618(98)00007-5 ↗
17. Masonry wall panels with GFRP and steel-cord strengthening subjected to cyclic shear: An experimental study10.1016/j.conbuildmat.2014.01.056 ↗
18. Fatigue tests of reinforced concrete beams strengthened using carbon fiber-reinforced polymer composites
19. Bentur, A., and Mindess, S. (2006). Fibre Reinforced Cementitious Composites, CRC Press. [2nd ed.].10.1201/9781482267747 ↗
20. Majumdar, A.J., and Laws, V. (1991). Glass Fibre Reinforced Cement, BSP Professional Books.
21. Durability evaluation of moderate temperature cured E-glass/vinylester systems10.1016/j.compstruct.2004.04.058 ↗
22. Durability of FRP rods for concrete structures10.1016/j.conbuildmat.2004.04.012 ↗
23. Accelerated aging tests for evaluations of durability performance of FRP reinforcing bars for concrete structures10.1016/j.compstruct.2005.08.015 ↗
24. Durability gap analysis for Fiber-Reinforced Polymer composites in civil infrastructure10.1061/(ASCE)1090-0268(2003)7:3(238) ↗
25. Durability prediction for GFRP reinforcing bars using short-term data of accelerated aging tests10.1061/(ASCE)1090-0268(2006)10:4(279) ↗
26. Hygrothermal ageing effects on FRP laminate and structural foam materials10.1016/S1359-835X(04)00121-6 ↗
27. Corradi, M., Righetti, L., Osofero, A.I., Borri, A., Castori, G., and Sisti, R. (2015, January 14–16). Accelerated aging and fatigue effects on GFRP grids. Proceedings of the sixth Congress on Collapses, Structural Reliability and Strengthening (IF CRASC 2015), Rome, Italy.
28. Micelli, F., and Aiello, M.A. (2017). Residual tensile strength of dry and impregnated reinforcement fibres after exposure to alkaline environments. Compos. Part B Eng., in press.
29. Ageing and fatigue combined effects on GFRP grids10.4028/www.scientific.net/KEM.747.525 ↗
30. CNR-DT 203/2006 (2007). CNR-DT 203/2006 Guide for the Design and Construction of Concrete Structures Reinforced with Fiber-Reinforced Polymer Bars, ROME—CNR.
31. ACI 440.3R/2004 (2004). Guide Test Methods for Fiber-Reinforced Polymers (FRPs) for Reinforcing or Strengthening Concrete Structures, American Concrete Institute.
32. ISO 10406-1/2008 (2008). Fibre-Reinforced Polymer (FRP) Reinforcement of Concrete—Test Methods, ISO.
33. The use of accelerated aging procedures to predict the long term strength of GRF composites10.1016/0008-8846(81)90117-4 ↗
34. ASTM D3039/2014 (2014). Standard Test Method for Tensile Properties of Polymer Matrix Composite Materials, ASTM.